The DLT 2.0 is a differential level transmitter designed for wastewater treatment applications, utilizing two non-contacting ultrasonic sensors to measure levels upstream and downstream of a bar screen. It simplifies instrumentation by combining level control, differential level control, and open channel flow monitoring into one device.
Key Features
  • Measures differential level and open channel flow with two ultrasonic sensors.
  • Three 4-20mA outputs for upstream level, downstream level (or flow), and differential level.
  • Built-in relays for level control, differential level control, or open channel flow.
  • Easy installation and operation with a built-in keypad and menu system.
Applications
  • Bar screen level control at wastewater treatment plant headworks.
  • Pump stations and combined sewer systems.
  • Monitoring and controlling bar screen levels with automatic activation of cleaning rakes.
Technical Specifications
  • Electronics Enclosure: NEMA4X (IP66) polycarbonate with a clear, shatterproof cover.
  • Accuracy: ±0.25% of Range or 2 mm, whichever is greater.
  • Display: White, backlit matrix displaying various levels and flow data.
  • Power Input: 100-240 V AC 50/60 Hz, 3 W maximum.
  • Operating Temperature: -20 °C to +60 °C (-5 °F to +140 °F).
  • Standard Sensor: PZ15 ultrasonic sensor with a maximum range of 4.6 m (15 ft).
Popular Options
  • Extended sensor cable lengths up to 152.4 m (500 ft).
  • Intrinsically Safe models for hazardous locations.
  • Data logger with USB output and Windows software.
  • Enclosure heater for temperatures below 0 °C (32 °F).
Conclusion
The Greyline DLT 2.0 is a versatile and efficient solution for monitoring and controlling levels in wastewater treatment facilities. Its non-contacting sensors require minimal maintenance, and its comprehensive features make it suitable for a wide range of applications.
See more

Catalog excerpts

Differential Level Transmitter - DLT 2.0-1

Differential level and control plus open channel flow monitoring with two noncontacting, ultrasonic sensors. Differential Level Transmitter with Non-Contacting Sensors One Instrument Does the Work of Three The DLT 2.0 is a simple solution for bar screen level control at wastewater treatment plant headworks, pump stations, and combined sewer systems. It includes two noncontacting ultrasonic sensors to measure level. Sensors are positioned above a channel, up and downstream from the bar screen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow. Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow), and differential level. Built-in relays can be calibrated for level control, differential level control, or open channel flow. THE RIGHT METER FOR • Bar screen Level • Pump Stations • Combined Sewer Systems • Level Control • Differential Level Control • Open Channel Flow One sensor can be installed on each side of a bar screen to continuously monitor, transmit, and control level. The built-in control relays or 4-20mA outputs can be used to automatically activate the bar screen rake at preset levels.

 Open the catalog to page 1
Differential Level Transmitter - DLT 2.0-2

Multi-function Level Transmitter Bar Screen Differential Plus Open Channel Flow Reduce costs and simplify instrumentation at treatment plant headworks. With a bar screen upstream from a flume, the Greyline DLT 2.0 can measure both differential level and flow through the flume with just two ultrasonic sensors and one electronics enclosure. 4-20mA Open Channel Flow The Greyline DLT 2.0 includes three 4-20mA outputs and displays flow rate and total flow through the flume, plus upstream level and differential level. Monitor, transmit, and control bar screen level with one instrument. Mount the ultrasonic...

 Open the catalog to page 2
Differential Level Transmitter - DLT 2.0-3

Technical Specifications GENERAL SPECIFICATIONS Electronics Enclosure: NEMA4X (IP66) polycarbonate with clear, shatterproof cover • ±0.25% of Range or 2 mm (0.08 in) whichever is greater • Repeatability and Linearity: ±0.1% White, backlit matrix - displays upstream, downstream, and differential level, open channel flow and totalizer, relay states, operating mode, and calibration menu Built-in 5-key calibrator with English, French, or Spanish language selection Analog Output: Three Isolated 4-20mA (upstream and downstream level (or open channel flow) and differential level, 1 kΩ load maximum....

 Open the catalog to page 3
Differential Level Transmitter - DLT 2.0-4

25 ft / 7.6 m RG62AU Coaxial Cable (50 ft / 15 m or 100 ft / 30 m Optional) 3/4” NPT Isolation Coupling (Supplied) DLT 2.0 Front & Side View Transmits 4-20mA output in proportion to Level Differential plus Open Channel Flow Bar screen control applications and sewage treatment plant headworks that previously required several instruments can all be monitored now by one ultrasonic level indicating transmitter. Install one sensor on each side of a bar screen (or any other flow obstruction) to continuously monitor and transmit differential level or mount the downstream sensor in a flume to measure...

 Open the catalog to page 4

All Pulsar Measurement catalogs and technical brochures

  1. MICROFLOW

    2  Pages

  2. FLOW PULSE

    2  Pages

  3. Radar Sensors

    4  Pages

  4. Model DFM 6.1

    4  Pages

  5. AVFM 6.1

    4  Pages

  6. TTFM 6.1

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.