YRM2.DIODE DC24-48V, 20A, DUAL REDUNDANCY MODULE REDUNDANCY MODULE Cost Effective Solution to Build Redundant Systems Dual Input with Single Output Alarm Relay-contacts for Each Input Path Two Diodes (Common Cathode) DC 24-48V ±25% (18-60Vdc) Wide-range Input Full Power Between -40°C and +60°C Width only 32mm Rugged Metal Housing Large Screw Terminals Easy Wiring: Distribution Terminal for Negative Pole Included 3 Year Warranty GENERAL DESCRIPTION SHORT-FORM DATA The YRM2.DIODE is a redundancy module, which can be used to build 1+1 and N+1 redundant systems. It is equipped with two input channels, which can be connected to power supplies with up to 10A output current and one output, which can carry nominal currents up to 20A. The module is suitable for power supplies with constant current overload behavior as well as any kind of “Hiccup” overload behavior. Input voltage Input voltage range Input current The YRM2.DIODE has a monitoring circuit included and is the perfect solution when the power supply has no DC-OK function. Two LEDs and two relay contacts signal when one of the two DC-input voltages is not in range due to a non-functioning or disconnected power supply. In addition to the YRM2.DIODE is the YR2.DIODE which has no monitoring circuitry included. This is the perfect fit when the power supply itself is already equipped with a DC-OK signal (e.g.: DIMENSION Q-Series). Large screw terminals allow an easy installation and a huge international approval package for a variety of applications makes this unit suitable for nearly every situation. ORDER NUMBERS Output current continuous for 5 seconds continuous for 5 seconds at cont. overload/ short circuit input: 2x5A input: 1x10A input: 2x10A at no load input: 2x5A input: 1x10A input: 2x10A operational, +60 to +70°C WxHxD Input to output voltage drop typ. 0.78V typ. 0.85V typ. 0.85V Power losses typ. 1.0W typ. 8.8W typ. 9.5W typ. 18W Temperature range -40°C to +70°C Derating 0.5A/°C Dimensions 32x124x117mm Redundancy Module Wall/ panel mount bracket Side mount bracket Apr. 2014 / Rev. 1.4 DS-YRM2.DIODE-EN All parameters are specified at 24V, 20A output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1YRM2.DIODE DC24-48V, 20A, DUAL REDUNDANCY MODULE The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. PE is the abbreviation for Protective Earth and has the same meaning as the symbol To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included. E.g.: DC 12V describes a 12V battery disregarding...
Open the catalog to page 2YRM2.DIODE DC24-48V, 20A, DUAL REDUNDANCY MODULE 1. INTENDED USE This redundancy module is designed for installation in an enclosure and is intended for the general use such as in industrial control, office, communication, and instrumentation equipment. This redundancy module can be used with any type of power supply as long as the maximum ratings are not exceeded. It is suitable for power supplies with constant current overload behavior as well as any kind of “Hiccup” overload behavior. Do not use this redundancy module in equipment, where malfunction may cause severe personal injury or threaten...
Open the catalog to page 3YRM2.DIODE DC24-48V, 20A, DUAL REDUNDANCY MODULE 3. INPUT AND OUTPUT CHARACTERISTICS Number of inputs Number of outputs Input voltage Input voltage range Voltage drop, input to output Input current Peak input current Output current Reverse current Reverse voltage Note 1: Note 2: ±25% The input circuitry must meet the SELV requirements stipulated by IEC/EN/UL 60950-1. at 2x5A, see Fig. 3-1 at 1x10A, see Fig. 3-2 at 2x10A, see Fig. 3-1 continuous continuous, see note 1 for up to 5 seconds for maximal 10ms per input continuous for up to 5 seconds at continuous overload or short circuit, see note...
Open the catalog to page 4□mnefUSIOfU Y-Series DC24-48V, 20A, DUAL REDUNDANCY MODULE Power losses typ. 8.8W input: 2x5A Standby power losses typ. LOW at no output current Both input voltages are monitored individually. If one input voltage is too low or completely lost, it will be indicated by an alarm relay contact. Each input has its own monitoring circuitry and relay contact. Alarm threshold nom. 21.5V (±0.5V) Relay contact opens immediately after the input voltage falls below this value. Isolation voltage see dielectric strength table in section 14. All parameters are specified at 24V, 20A output current, 25°C ambient...
Open the catalog to page 5□innerusoru Y-Series DC24-48V, 20A, DUAL REDUNDANCY MODULE I 6. LIFETIME EXPECTANCY AND MTBF_ The redundancy module has two input channels which are completely independent from each other. Each control circuit, auxiliary voltage source, or other circuitry in the module are designed separately for each input. The dual input redundancy module can be considered as two single redundancy modules combined together in one housing. The only common point is the circuit trace that ties the two separate circuits together at the output. The MTBF figures below are for the entire dual input module. If the...
Open the catalog to page 6YRM2.DIODE DC24-48V, 20A, DUAL REDUNDANCY MODULE 7. TERMINALS AND WIRING Type Solid wire Stranded wire American Wire Gauge Max. wire diameter Wire stripping length Screwdriver Recommended tightening torque Input and output terminals Screw terminals IP20 Finger safe construction. Suitable for field installation. 0.5-6mm2 0.5-4mm2 20-10 AWG 2.8mm (including ferrule) 7mm / 0.28inch 3.5mm slotted or Pozidrive No 2 0.8Nm / 7lb.in Alarm-signal terminals Screw terminals, pluggable IP20 Finger safe construction. Suitable for field installation. 0.2-1.5mm2 0.2-1.5mm2 22-14 AWG 6mm / 0.25inch 3mm slotted...
Open the catalog to page 7□mnefUSIOfU Y-Series DC24-48V, 20A, DUAL REDUNDANCY MODULE I 9. FRONT SIDE AND USER ELEMENTS B Chassis ground terminal Connection of the chassis to ground is optional and not required since the unit fulfils the requirements according to protection class III. C Input terminals for input 1 D Input terminals for input 2 E Alarm-signal terminals for input 1 monitoring (relay contact) F Alarm-signal terminals for input 2 monitoring (relay contact) G Green LED for input 1 (LED is on, when input voltage is in range) H Green LED for input 2 (LED is on, when input voltage is in range) All parameters are...
Open the catalog to page 818 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
21 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages