PULS □innemsiom Q-Series 36V, 26.7A, Three Phase Input Power Supply 3AC 380-480V wide-range input Three input fuses included Width only 110mm, weight only 1.5kg 95.3% full load and excellent partial load efficiencies 50% BonusPower, 1440W for up to 4s 72A peak current for 10ms for easy fuse tripping Active PFC (power factor correction) Active filtering of input transients Negligible low input inrush current surge Full power between -25°C and +60°C Current sharing feature for parallel use Internal data logging for troubleshooting included Remote control of output voltage DC-OK relay contact Shut-down input 3 year warranty The most outstanding features of the DIMENSION Q-Series DIN rail power supplies are the extremely high efficiencies and the small sizes, which are achieved by a synchronous rectification and other technological designs. Large power reserves of 150% support the starting of heavy loads such as DC-motors or capacitive loads. In many cases this allows the use of a unit from a lower wattage class which saves space and money. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager, the three input fuses and near zero input inrush current make installation and usage simple. Diagnostics are easy due to the DC-OK relay, a green DC-OK LED and the red overload LED. A large international approval package for a variety of applications makes this unit suitable for nearly every application. | Short-form Data Output voltage Adjustment range Output current Output power Output ripple Input voltage Mains frequency AC Input current Power factor AC Inrush current Efficiency Power losses Temperature range Derating Hold-up time Dimensions (wxhxd) Weight factory setting 36V continuous short term (4s) continuous short term (4s) 20Hz to 20MHz -15%/+10% Order Numbers | Main Approvals Power Supply QT40.361 36-42V Standard unit Accessory ZM2.WALL Wall mount bracket For details and the complete approval list, see chapter 22. All parameters are specified at 36V, 26.7A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Open the catalog to page 1□innemsiom Q-Series 36V, 26.7A, Three Phase Input The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. PE and symbol Earth, Ground t.b.d. PE is the abbreviation for Protective Earth and has the same meaning as the symbol . This document uses the term "earth" which is the same as the U.S. term "ground". To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents...
Open the catalog to page 2QT40.361 36V, 26.7A, THREE PHASE INPUT 1. INTENDED USE This device is designed for installation in an enclosure and is intended for commercial use, such as in industrial control, process control, monitoring, measurement equipment or the like. Do not use this device in equipment, where malfunctioning may cause severe personal injury or threaten human life without additional appropriate safety devices, that are suited for the end application. If this device is used in a manner outside of its specification, the protection provided by the device may be impaired. 2. INSTALLATION INSTRUCTIONS WARNING...
Open the catalog to page 3□innemsiom Q-Series 36V, 26.7A, Three Phase Input AC input nom. 3AC 380-480V suitable for TN, TT and IT mains networks, grounding of one phase is allowed AC input range 3x 323-528Vac continuous operation Turn-on voltage typ. 3x 305Vac steady-state value, load independent, see Fig. 3-1 Shut-down voltage typ. 3x 275Vac steady-state value, load independent, see Fig. 3-1 Input current typ. 1.58A 1.3A at 36V, 26.7A, symmetrical phase voltages, Rise time typ. 40ms 40ms at 36V, 26.7A, resistive load, 0mF see Fig. 3-2 All parameters are specified at 36V, 26.7A, 3x400Vac, 25°C ambient and after a 5 minutes...
Open the catalog to page 4□innemsiom Q-Series 36V, 26.7A, Three Phase Input The power supply is equipped with an active inrush current limitation circuit, which limits the input inrush current after turn-on to a negligible low value. The input current is usually smaller than the steady state input current. Inrush current* Inrush energy Inrush delay over entire temperature range over entire temperature range over entire temperature range *) The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Fig. 4-1 Typical turn-on behaviour at nominal load and 25°C ambient temperature...
Open the catalog to page 5QT40.361 □innemsiom Q-Series 36V, 26.7A, Three Phase Input 6. Output Output voltage Adjustment range Factory setting Line regulation Load regulation Ripple and noise voltage Output current Output power BonusPower time BonusPower recovery time Overload behaviour Short-circuit current** Output capacitance at clockwise end position of potentiometer ±0.2%, at full load, cold unit, in "single use" mode ±0.2%, at full load, cold unit, in "parallel use" mode at no load, cold unit, in "parallel use" mode 3x323-576Vac in "single use" mode: static value, 0A^26A, see Fig. 6-1 in "parallel use" mode: static...
Open the catalog to page 6QT40.361 36V, 26.7A, THREE PHASE INPUT Fig. 6-1 Output voltage vs. output current in “single use” mode, typ. Output V ol tage Continuously available Short-term (4s) BonusPower Output Vol tage (Parallel Use, typ.) Fig. 6-2 Output voltage vs. output current in “parallel use” mode, typ. Adjustment Range Output Current Output Current Fig. 6-3 Bonus time vs. output power Fig. 6-4 Dynamic overcurrent capability, typ. Output V ol tage (dynamic behavior, < 10ms) Bonus Time Output Power Adjustment Range Output Current Fig. 6-5 BonusPower recovery time Limitati on by Power Manager Output Voltage Recovery...
Open the catalog to page 7□innemsiom Q-Series 36V, 26.7A, Three Phase Input *) Curves and figures for operation on only 2 legs of a 3-phase system can be found in chapter 26.4 Fig. 7-1 Hold-up time vs. input voltage Input Voltage All parameters are specified at 36V, 26.7A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Open the catalog to page 818 Pages
18 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
21 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages