Catalog excerpts

QT40.241 24V, 40A, THREE PHASE INPUT POWER SUPPLY 3AC 380-480V Wide-range Input Three Input Fuses Included Width only 110mm, Weight only 1.5kg 95.3% Full Load and Excellent Partial Load Efficiencies 50% BonusPower®, 1440W for up to 4s 110A Peak Current for 25ms for Easy Fuse Tripping Active PFC (Power Factor Correction) Active Filtering of Input Transients Negligible Low Input Inrush Current Surge Full Power Between -25°C and +60°C Current Sharing Feature for Parallel Use Internal Data Logging for Troubleshooting Included. Remote Control of Output Voltage DC-OK Relay Contact Shut-down Input 3 Year Warranty GENERAL DESCRIPTION SHORT-FORM DATA The most outstanding features of the DIMENSION QSeries DIN-rail power supplies are the extremely high efficiencies and the small sizes, which are achieved by a synchronous rectification and other technological designs. Output voltage Adjustment range Output current A large international approval package for a variety of applications makes this unit suitable for nearly every application. DC 24V 24 - 28V 40 – 34.3A 60 – 51.5A Output power 960W 1440W Output ripple < 100mVpp Input voltage 3AC 380-480V Mains frequency 50-60Hz AC Input current 1.65 / 1.35A Power factor 0.88 / 0.90 AC Inrush current typ. 4.5A peak Efficiency 95.3 / 95.2% Losses 47.3 / 48.4W Temperature range -25°C to +70°C Derating 24W/°C Hold-up time typ. 25 / 25ms Dimensions 110x124x127mm Weight 1500g / 3.3lb ORDER NUMBERS Large power reserves of 150% support the starting of heavy loads such as DC-motors or capacitive loads. In many cases this allows the use of a unit from a lower wattage class which saves space and money. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager, the three input fuses and near zero input inrush current make installation and usage simple. Diagnostics are easy due to the DC-ok relay, a green DC-OK LED and the red overload LED. Power Supply Wall mount bracket Buffer unit Redundancy module Nov. 2013 / Rev. 2.2 DS-QT40.241-EN All parameters are specified at 24V, 40A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1
QT40.241 24V, 40A, THREE PHASE INPUT The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents a nominal voltage with standard...
Open the catalog to page 2
QT40.241 24V, 40A, THREE PHASE INPUT 1. INTENDED USE This device is designed for installation in an enclosure and is intended for the general professional use such as in industrial control, office, communication, and instrumentation equipment. Do not use this power supply in equipment, where malfunction may cause severe personal injury or threaten human life. This device is designed for use in hazardous, non-hazardous, ordinary or unclassified locations. 2. INSTALLATION REQUIREMENTS This device may only be installed and put into operation by qualified personnel. This device does not contain...
Open the catalog to page 3
□innefUSIOfU Q-Series 24V, 40A, THREE PHASE INPUT suitable for TN, TT and IT mains networks, grounding of one phase is allowed except in UL 508 continuous operation Allowed voltage L to earth Input frequency Turn-on voltage Shut-down voltage typ. 3x 305Vac steady-state value, load independent, see Fig. 3-1 typ. 3x 275Vac steady-state value, load independent, see Fig. 3-1 Input current 1.35A at 24V, 40A, symmetrical phase voltages, Power factor*' Start-up delay Rise time Turn-on overshoot *) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit....
Open the catalog to page 4
QT40.241 24V, 40A, THREE PHASE INPUT 4. INPUT INRUSH CURRENT The power supply is equipped with an active inrush current limitation circuit, which limits the input inrush current after turn-on to a negligible low value. The input current is usually smaller than the steady state input current. Inrush current*) Inrush energy Inrush delay *) over entire temperature range over entire temperature range over entire temperature range The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Fig. 4-1 Typical turn-on behaviour at nominal load and...
Open the catalog to page 5
QT40.241 24V, 40A, THREE PHASE INPUT 6. OUTPUT Output voltage Adjustment range Ripple and noise voltage Output current Output power BonusPower® time BonusPower® recovery time Overload behavior Short-circuit current**) Output capacitance *) Line regulation Load regulation Factory setting guaranteed at clockwise end position of potentiometer ±0.2%, at full load, cold unit, in “single use” mode ±0.2%, at full load, cold unit, in “parallel use” mode at no load, cold unit, in “parallel use” mode 3x323-576Vac in “single use” mode: static value, 0A 40A, see Fig. 6-1 in “parallel use” mode: static...
Open the catalog to page 6
□innefUSIOfU Q-Series 24V, 40A, THREE PHASE INPUT Fig. 6-1 Output voltage vs. output current in Output Voltage Adjustment Range Output Current Fig. 6-2 Output voltage vs. output current in Output Voltage (Parallel Use, typ.) Output Current Fig. 6-3 Bonus time vs. output power Bonus Time Output Power Fig. 6-4 Dynamic overcurrent capability, typ. Output Voltage (dynamic behavior, < 25ms) Fig. 6-5 BonusPower recovery time All parameters are specified at 24V, 40A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Open the catalog to page 7
QT40.241 24V, 40A, THREE PHASE INPUT 7. HOLD-UP TIME Hold-up Time Curves and figures for operation on only 2 legs of a 3-phase system can be found in chapter 25.4 Fig. 7-1 Hold-up time vs. input voltage Hold-up Time Fig. 7-2 Shut-down behavior, definitions Input Voltage Hold-up Time Input Voltage Output Voltage Nov. 2013 / Rev. 2.2 DS-QT40.241-EN All parameters are specified at 24V, 40A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 8All PULS GmbH catalogs and technical brochures
-
XT40.361
21 Pages
-
CP10.241-S1
33 Pages
-
CD10.242
29 Pages
-
QT40.361
28 Pages
-
MLY02.100
18 Pages
-
MLY10.241
18 Pages
-
FPT500 series
35 Pages
-
FPS300 series
32 Pages
-
SLR01
2 Pages
-
SLZ14
2 Pages
-
SLZ12
2 Pages
-
SLZ11
2 Pages
-
SLZ02
2 Pages
-
SLR10.100
2 Pages
-
SL40.301
2 Pages
-
SL40.300
2 Pages
-
SL30.300
2 Pages
-
SL20.303
2 Pages
-
SL20.310
2 Pages
-
SL20.301
2 Pages
-
SL20.300
2 Pages
-
SL10.309
2 Pages
-
SL10.305
4 Pages
-
SL10.300
2 Pages
-
SL5.300
2 Pages
-
SL30.100
2 Pages
-
SL20.115
2 Pages
-
SL20.113
2 Pages
-
SL20.112
2 Pages
-
SL20.111
2 Pages
-
SL20.110
2 Pages
-
SL20.101
2 Pages
-
SL20.100
2 Pages
-
SL10.106
2 Pages
-
SL10.105
2 Pages
-
SL10.10
2 Pages
-
SL10.104
2 Pages
-
SL10.101
2 Pages
-
SL10.100
2 Pages
-
SL5.105
2 Pages
-
SL5.102
2 Pages
-
SL5.100
2 Pages
-
SL4.100
2 Pages
-
SL2.103
2 Pages
-
SL2.100
2 Pages
-
ML100.200
2 Pages
-
ML90.200
2 Pages
-
ML100.105
2 Pages
-
ML100.102
2 Pages
-
ML100.100
2 Pages
-
ML95.100
2 Pages
-
ML70.100
2 Pages
-
ML60.121
23 Pages
-
ML50.111
2 Pages
-
ML50.109
20 Pages
-
ML50.105
2 Pages
-
ML50.102
2 Pages
-
ML50.101
2 Pages
-
ML50.100
20 Pages
-
ML30.241
23 Pages
-
ML30.106
2 Pages
-
ML30.102
2 Pages
-
ML30.101
2 Pages
-
ML30.100
2 Pages
-
ML15.241
23 Pages
-
ML15.121
23 Pages
-
ML15.051
22 Pages
-
YRM2.DIODE
19 Pages
-
YR80.241
17 Pages
-
YR40.241
17 Pages
-
YR2.DIODE
19 Pages
-
XT40.722
19 Pages
-
XT40.721
19 Pages
-
XT40.482
20 Pages
-
XT40.481
20 Pages
-
XT40.362
20 Pages
-
XT40.242
20 Pages
-
XT40.241
20 Pages
-
ZM15.SIDE
2 Pages
-
ZM14.SIDE
2 Pages
-
ZM13.SIDE
2 Pages
-
ZM12.SIDE
2 Pages
-
ZM11.SIDE
2 Pages
-
ZM2.WALL
3 Pages
-
ZM1.WALL
2 Pages
-
ZM1.UBC10
2 Pages
-
UZS24.100
3 Pages
-
UF20.481
13 Pages
-
UF20.241
11 Pages
-
UZO12.26
2 Pages
-
UZO12.07
9 Pages
-
UZK12.261
8 Pages
-
UZK12.071
9 Pages
-
UBC10.241-N1
23 Pages
-
UBC10.241
23 Pages
-
UB10.245
24 Pages
-
UB10.242
21 Pages
-
UB10.241
23 Pages
-
QT40.481
28 Pages
-
QT20.481
23 Pages
-
QT20.361
23 Pages
-
QT20.241-C1
23 Pages
-
QT20.241
23 Pages
-
QTD20.241
22 Pages
-
QS10.481-D1
27 Pages
-
QS10.241-D1
27 Pages
-
QS40.484
28 Pages
-
QS40.244
28 Pages
-
QS20.481
25 Pages
-
QS20.361
25 Pages
-
QS20.244
25 Pages
-
QS20.241-C1
26 Pages
-
QS20.241-A1
26 Pages
-
QS20.241
26 Pages
-
QS10.481
27 Pages
-
QS10.DNET
22 Pages
-
QS10.301
26 Pages
-
QS10.241-C1
27 Pages
-
QS10.241-A1
27 Pages
-
QS10.241
28 Pages
-
QS10.121
26 Pages
-
QS5.DNET
21 Pages
-
QS5.241-A1
26 Pages
-
QS5.241
26 Pages
-
QS3.241
25 Pages
-
PISA11.CLASS2
19 Pages
-
PISA11.206212
23 Pages
-
PISA11.203206
23 Pages
-
PISA11.410
23 Pages
-
PISA11.406
23 Pages
-
PISA11.404
23 Pages
-
PISA11.403
23 Pages
-
PISA11.402
23 Pages
-
PISA11.401
23 Pages
-
PIC240.241D
21 Pages
-
PIC120.241C
21 Pages
-
PAS395
14 Pages
-
CT10.481
22 Pages
-
CT10.241
22 Pages
-
CT5.241
21 Pages
-
CT5.121
21 Pages
-
CS10.481
20 Pages
-
CS10.244
21 Pages
-
CS10.243
19 Pages
-
CS10.242
19 Pages
-
CS10.241-S1
20 Pages
-
CS10.241
20 Pages
-
CS5.244
20 Pages
-
CS5.243
19 Pages
-
CS5.241-S1
20 Pages
-
CS5.241-C1
20 Pages
-
CS5.241
20 Pages
-
CS3.241
21 Pages
-
CPS20.241-C1
26 Pages
-
CPS10.241
26 Pages
-
CP10.242
27 Pages
-
CD5.243
22 Pages
-
CD5.242
22 Pages
-
CD5.241-S1
23 Pages
-
CD5.241-L1
21 Pages
-
CD5.241
22 Pages
-
CD5.121
22 Pages
-
PIC120.242C
21 Pages
-
PIC240.241C
20 Pages
-
QS40.361
27 Pages
-
QS40.481
28 Pages
-
UB20.241
31 Pages
-
UZK24.071
9 Pages
-
UZK24.121
9 Pages
-
UZO24.071
9 Pages
-
UZO24.121
9 Pages
-
UC10.241
27 Pages
-
UC10.242
27 Pages
-
YR40.242
17 Pages
-
YR40.245
18 Pages
Archived catalogs
-
DECENTRALIZED POWER SUPPLIES
9 Pages
-
PIANO
5 Pages
-
PIANO PIC
2 Pages
-
selection guide 2018
31 Pages
-
PULS CP
7 Pages
-
Selection Guide 2015/2016
25 Pages
-
PIC120.241D_2015
22 Pages
-
CP10.121
26 Pages
-
PIC120.241D_2014
21 Pages
-
YR40.482
17 Pages
-
YR80.242
17 Pages
-
SLA3.100
4 Pages
-
SLA4.100
4 Pages
-
SLA8.100
4 Pages
-
SLA8.300
4 Pages
-
SLAD4.100
4 Pages
-
SLD2.100
2 Pages
-
SLR02
2 Pages
-
SLR2.100
2 Pages
-
SLR5.100
2 Pages
-
SLR10.108
2 Pages
-
SLV20.200
4 Pages
-
SLZ10-14
2 Pages
-
ML60.122
23 Pages
-
ML60.241
23 Pages
-
ML60.242
23 Pages
-
ML120.241
22 Pages
-
ML120.244
21 Pages
-
ML120.CLASS2
19 Pages
-
ZM3.WALL
1 Pages
-
CPS20.481-D1
25 Pages
-
CPS20.241-D1
25 Pages
-
Selection Guide 2013
19 Pages
-
QS40.241, QS40.241-A1
28 Pages
-
CPS20.241
25 Pages
-
CPS20.361
25 Pages
-
CPS20.481
25 Pages
-
CPS20.121
25 Pages
-
Products 2009-2010
28 Pages
-
Products 2007
34 Pages