QT20.481 48V, 10A, THREE PHASE INPUT POWER SUPPLY • • • • • • • • • • • • 3AC 380-480V Wide-range Input 2-Phase Operation also Possible Efficiency up to 95.4% Width only 65mm 150% Peak Load Capability Active Power Factor Correction PFC Active Input Transient Filter Full Power Between -25°C and +60°C Minimal Inrush Current DC-OK Relay Contact Quick-connect Spring Clamp Terminals 3 Year Warranty The most outstanding features of this Dimension QSeries DIN-rail power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details. Output voltage Adjustment range Output current Large power reserves of 150% support the starting of heavy loads such as DC motors or capacitive loads. In many cases this allows the use of a unit from a lower wattage class which saves space and money. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager and virtually no input inrush current make installation and usage simple with no jumpers and switches necessary. Diagnostics are easy due to the dry DC-ok contact, a green DC-ok LED and red overload LED. Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation. DC 48V 48-55V 10A 15A Output power 480W 720W Output ripple < 100mVpp Input voltage AC 380-480V Mains frequency 50-60Hz AC Input current 0.79 / 0.65A Power factor 0.94 / 0.95 AC Inrush current typ. 3A peak Efficiency 95.4 / 95.0% Losses 23.1 / 25.3W Temperature range -25°C to +70°C Derating 12W/°C Hold-up time typ. 22 / 22ms Dimensions 65x124x127mm Power Supply Wall mount bracket Side mount bracket Decoupling module Buffer unit Oct. 2006 / Rev. 1.0 DS-QT20.481-EN All parameters are specified at 48V, 10A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1QT20.481 48V, 10A, THREE PHASE INPUT INTENDED USE The power supply shall only be installed and put into operation by qualified personnel. This power supply is designed for installation in an enclosure and is intended for the general use, such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document...
Open the catalog to page 2□innefUSIOfU Q-Series 48V, 10A, THREE PHASE INPUT nom. 3AC380-480V Wide-range input, TN-, TT-, IT-Mains, see Fig. 5-1 Consult factory if one phase is earthed. Input frequency min. 3x 280-323Vac Full power for 200ms, no damage between 0 and 280Vac Turn-on voltage Shut-down voltage Input current Power factor *) typ. 0.79A 0.65A At 48V, 10A, all three phases equal voltage Start-up delay Rise time Turn-on overshoot *) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. Fig. 5-1 Input voltage range full power ■ Rated input range Fig. 5-2 Turn-on...
Open the catalog to page 3□innefUSIOfU Q-Series 48V, 10A, THREE PHASE INPUT The QT20 series shall not be used with a DC-input voltage without consulting PULS. Check QTD20.241 for DC-input voltage, (special version for intermediate bus systems, drive systems) I 7. INPUT INRUSH CURRENT_ An active inrush limitation circuitry limits the input inrush current after turn-on of the input voltage and after short input voltage interruptions. The charging current into EMI suppression capacitors is disregarded in the first milliseconds after switch-on. peak peak Fig. 7-1 Input inrush current, typical behavior Upper curve:...
Open the catalog to page 4QT20.481 48V, 10A, THREE PHASE INPUT 8. OUTPUT Output voltage Adjustment range Factory setting Line regulation Load regulation Ripple and noise voltage Output capacitance Guaranteed, multi turn potentiometer At clockwise end position of potentiometer ±0.2%, at full load, cold unit 320 to 552Vac Static value, 0A 10A 0A 20Hz to 20MHz, 50Ohm The energy of the bulk capacitor on the input side will be transferred to the output to supply short load peaks. Continuous power capability Output current Output power Short-circuit current At 48V, see Fig. 8-1 At 55V, see Fig. 8-1 48V, continuous 55V,...
Open the catalog to page 5□innefUSIOfU Q-Series 48V, 10A, THREE PHASE INPUT Fig. 8-1 Output voltage vs. output current, typ. Output Voltage Fig. 8-2 Bonus time vs. output power Bonus Time Output Power Fig. 8-3 BonusPower® recovery time Power <150% / Power Manager I^BonusJ Recovery Time i Time I i Bonus Power disabled i Bonus Power® is available as soon as power comes on and immediately after the end of an output short circuit. Fig. 8-4 BonusPower® after input turn-on Fig. 8-5 BonusPower® after output short All parameters are specified at 48V, 10A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless...
Open the catalog to page 6□innefUSIOfU Q-Series 48V, 10A, THREE PHASE INPUT Hold-up Time Fig. 9-1 Hold-up time vs. input voltage Fig. 9-2 Shut-down behavior, definitions Hold-up Time Input Voltage ! Zero Transition Hold-up Time I 10. DC-OK RELAY CONTACT This feature monitors the output voltage, which is produced by the power supply itself. It is independent of a back- fed voltage from a unit which is connected in parallel to the power supply output. Contact closes As soon as the output voltage reaches the adjusted output voltage. Contact opens As soon as the output voltage dips more than 10% below the adjusted...
Open the catalog to page 7QT20.481 48V, 10A, THREE PHASE INPUT 11. EFFICIENCY AND POWER LOSSES Efficiency Power losses Fig. 11-1 Efficiency vs. output current at 48V Fig. 11-2 Losses vs. output current at 48V Power Losses Fig. 11-3 Efficiency vs. input voltage, 48V, 10A Output Current Fig. 11-4 Losses vs. input voltage, 48V, 10A Power Losses Input Voltage Oct. 2006 / Rev. 1.0 DS-QT20.481-EN All parameters are specified at 48V, 10A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 8All PULS GmbH catalogs and technical brochures
-
FPT500 series
35 Pages
-
FPS300 series
32 Pages
-
CD10.242
29 Pages
-
DECENTRALIZED POWER SUPPLIES
9 Pages
-
PIANO
5 Pages
-
PIANO PIC
2 Pages
-
selection guide 2018
31 Pages
-
PULS CP
7 Pages
-
Selection Guide 2015/2016
25 Pages
-
CP10.241
27 Pages
-
CP10.241-S1
27 Pages
-
PIC120.241D
22 Pages
-
CP10.121
26 Pages
-
SLR01
2 Pages
-
SLZ14
2 Pages
-
SLZ12
2 Pages
-
SLZ11
2 Pages
-
SLZ02
2 Pages
-
SLR10.100
2 Pages
-
SL40.301
2 Pages
-
SL40.300
2 Pages
-
SL30.300
2 Pages
-
SL20.303
2 Pages
-
SL20.310
2 Pages
-
SL20.301
2 Pages
-
SL20.300
2 Pages
-
SL10.309
2 Pages
-
SL10.305
4 Pages
-
SL10.300
2 Pages
-
SL5.300
2 Pages
-
SL30.100
2 Pages
-
SL20.115
2 Pages
-
SL20.113
2 Pages
-
SL20.112
2 Pages
-
SL20.111
2 Pages
-
SL20.110
2 Pages
-
SL20.101
2 Pages
-
SL20.100
2 Pages
-
SL10.106
2 Pages
-
SL10.105
2 Pages
-
SL10.10
2 Pages
-
SL10.104
2 Pages
-
SL10.101
2 Pages
-
SL10.100
2 Pages
-
SL5.105
2 Pages
-
SL5.102
2 Pages
-
SL5.100
2 Pages
-
SL4.100
2 Pages
-
SL2.103
2 Pages
-
SL2.100
2 Pages
-
ML100.200
2 Pages
-
ML90.200
2 Pages
-
ML100.105
2 Pages
-
ML100.102
2 Pages
-
ML100.100
2 Pages
-
ML95.100
2 Pages
-
ML70.100
2 Pages
-
ML60.121
23 Pages
-
ML50.111
2 Pages
-
ML50.109
20 Pages
-
ML50.105
2 Pages
-
ML50.102
2 Pages
-
ML50.101
2 Pages
-
ML50.100
20 Pages
-
ML30.241
23 Pages
-
ML30.106
2 Pages
-
ML30.102
2 Pages
-
ML30.101
2 Pages
-
ML30.100
2 Pages
-
ML15.241
23 Pages
-
ML15.121
23 Pages
-
ML15.051
22 Pages
-
YRM2.DIODE
19 Pages
-
YR80.241
17 Pages
-
YR40.241
17 Pages
-
YR2.DIODE
19 Pages
-
XT40.722
19 Pages
-
XT40.721
19 Pages
-
XT40.482
20 Pages
-
XT40.481
20 Pages
-
XT40.362
20 Pages
-
XT40.361
20 Pages
-
XT40.242
20 Pages
-
XT40.241
20 Pages
-
ZM15.SIDE
2 Pages
-
ZM14.SIDE
2 Pages
-
ZM13.SIDE
2 Pages
-
ZM12.SIDE
2 Pages
-
ZM11.SIDE
2 Pages
-
ZM2.WALL
3 Pages
-
ZM1.WALL
2 Pages
-
ZM1.UBC10
2 Pages
-
UZS24.100
3 Pages
-
UF20.481
13 Pages
-
UF20.241
11 Pages
-
UZO12.26
2 Pages
-
UZO12.07
9 Pages
-
UZK12.261
8 Pages
-
UZK12.071
9 Pages
-
UBC10.241-N1
23 Pages
-
UBC10.241
23 Pages
-
UB10.245
24 Pages
-
UB10.242
21 Pages
-
UB10.241
23 Pages
-
QT40.481
28 Pages
-
QT40.241
28 Pages
-
QT20.361
23 Pages
-
QT20.241-C1
23 Pages
-
QT20.241
23 Pages
-
QTD20.241
22 Pages
-
QS10.481-D1
27 Pages
-
QS10.241-D1
27 Pages
-
QS40.484
28 Pages
-
QS40.244
28 Pages
-
QS20.481
25 Pages
-
QS20.361
25 Pages
-
QS20.244
25 Pages
-
QS20.241-C1
26 Pages
-
QS20.241-A1
26 Pages
-
QS20.241
26 Pages
-
QS10.481
27 Pages
-
QS10.DNET
22 Pages
-
QS10.301
26 Pages
-
QS10.241-C1
27 Pages
-
QS10.241-A1
27 Pages
-
QS10.241
28 Pages
-
QS10.121
26 Pages
-
QS5.DNET
21 Pages
-
QS5.241-A1
26 Pages
-
QS5.241
26 Pages
-
QS3.241
25 Pages
-
PISA11.CLASS2
19 Pages
-
PISA11.206212
23 Pages
-
PISA11.203206
23 Pages
-
PISA11.410
23 Pages
-
PISA11.406
23 Pages
-
PISA11.404
23 Pages
-
PISA11.403
23 Pages
-
PISA11.402
23 Pages
-
PISA11.401
23 Pages
-
PIC240.241D
21 Pages
-
PIC120.241C
21 Pages
-
PAS395
14 Pages
-
CT10.481
22 Pages
-
CT10.241
22 Pages
-
CT5.241
21 Pages
-
CT5.121
21 Pages
-
CS10.481
20 Pages
-
CS10.244
21 Pages
-
CS10.243
19 Pages
-
CS10.242
19 Pages
-
CS10.241-S1
20 Pages
-
CS10.241
20 Pages
-
CS5.244
20 Pages
-
CS5.243
19 Pages
-
CS5.241-S1
20 Pages
-
CS5.241-C1
20 Pages
-
CS5.241
20 Pages
-
CS3.241
21 Pages
-
CPS20.241-C1
26 Pages
-
CPS10.241
26 Pages
-
CP10.242
27 Pages
-
CD5.243
22 Pages
-
CD5.242
22 Pages
-
CD5.241-S1
23 Pages
-
CD5.241-L1
21 Pages
-
CD5.241
22 Pages
-
CD5.121
22 Pages
-
PIC120.242C
21 Pages
-
PIC240.241C
20 Pages
-
QS40.361
27 Pages
-
QS40.481
28 Pages
-
QT40.361
27 Pages
-
UB20.241
31 Pages
-
UZK24.071
9 Pages
-
UZK24.121
9 Pages
-
UZO24.071
9 Pages
-
UZO24.121
9 Pages
-
UC10.241
27 Pages
-
UC10.242
27 Pages
-
YR40.242
17 Pages
-
YR40.245
18 Pages
-
YR40.482
17 Pages
-
YR80.242
17 Pages
-
SLA3.100
4 Pages
-
SLA4.100
4 Pages
-
SLA8.100
4 Pages
-
SLA8.300
4 Pages
-
SLAD4.100
4 Pages
-
SLD2.100
2 Pages
-
SLR02
2 Pages
-
SLR2.100
2 Pages
-
SLR5.100
2 Pages
-
SLR10.108
2 Pages
-
SLV20.200
4 Pages
-
SLZ10-14
2 Pages
-
ML60.122
23 Pages
-
ML60.241
23 Pages
-
ML60.242
23 Pages
-
ML120.241
22 Pages
-
ML120.244
21 Pages
-
ML120.CLASS2
19 Pages
-
MLY02.100
16 Pages
-
MLY10.241
16 Pages
-
ZM3.WALL
1 Pages
-
CPS20.481-D1
25 Pages
-
CPS20.241-D1
25 Pages
-
Selection Guide 2013
19 Pages
-
QS40.241, QS40.241-A1
28 Pages
-
CPS20.241
25 Pages
-
CPS20.361
25 Pages
-
CPS20.481
25 Pages
-
CPS20.121
25 Pages
Archived catalogs
-
PIC120.241D
21 Pages
-
Products 2009-2010
28 Pages
-
Products 2007
34 Pages