
QT20.361 36V, 13.3A, THREE PHASE INPUT POWER SUPPLY • • • • • • • • • • • • 3AC 380-480V Wide-range Input 2-Phase Operation also Possible Efficiency up to 94.8% Width only 65mm 150% Peak Load Capability Active Power Factor Correction PFC Active Input Transient Filter Full Power Between -25°C and +60°C Minimal Inrush Current DC-OK Relay Contact Quick-connect Spring Clamp Terminals 3 Year Warranty The most outstanding features of this Dimension QSeries DIN-rail power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details. Output voltage Adjustment range Output current Large power reserves of 150% support the starting of heavy loads such as DC motors or capacitive loads. In many cases this allows the use of a unit from a lower wattage class which saves space and money. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager and virtually no input inrush current make installation and usage simple with no jumpers and switches necessary. Diagnostics are easy due to the dry DC-ok contact, a green DC-ok LED and red overload LED. Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation. DC 36V 36-42V 13.3A 20A Output power 480W 720W Output ripple < 100mVpp Input voltage AC 380-480V Mains frequency 50-60Hz AC Input current 0.79 / 0.65A Power factor 0.94 / 0.95 AC Inrush current typ. 3A peak Efficiency 94.8 / 94.6% Losses 26.3 / 27.4W Temperature range -25°C to +70°C Derating 12W/°C Hold-up time typ. 22 / 22ms Dimensions 65x124x127mm Power Supply Wall mount bracket Side mount bracket Decoupling module Oct. 2006 / Rev. 1.0 DS-QT20.361-EN All parameters are specified at 36V, 13.3A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1QT20.361 36V, 13.3A, THREE PHASE INPUT INTENDED USE The power supply shall only be installed and put into operation by qualified personnel. This power supply is designed for installation in an enclosure and is intended for the general use, such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document...
Open the catalog to page 2QT20.361 36V, 13.3A, THREE PHASE INPUT Input frequency Turn-on voltage Shut-down voltage Input current Power factor *) Start-up delay Rise time Turn-on overshoot At 36V, 13.3A, all three phases equal voltage See Fig. 5-3 At 36V, 13.3A, see Fig. 5-4 See Fig. 5-2 0mF, 36V, 13.3A, see Fig. 5-2 13mF, 36V, 13.3A, see Fig. 5-2 See Fig. 5-2 The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. Fig. 5-1 Input voltage range Intput Voltage Rated input range Fig. 5-2 Turn-on behavior, definitions Output Voltage Start-up delay Fig. 5-4 Power factor vs. output load...
Open the catalog to page 3□innefUSIDfU Q-Series 36V, 13.3A, THREE PHASE INPUT The QT20 series shall not be used with a DC-input voltage without consulting PULS. Check QTD20.241 for DC-input voltage, (special version for intermediate bus systems, drive systems) I 7. INPUT INRUSH CURRENT_ An active inrush limitation circuitry limits the input inrush current after turn-on of the input voltage and after short input voltage interruptions. The charging current into EMI suppression capacitors is disregarded in the first milliseconds after switch-on. Fig. 7-1 Input inrush current, typical behavior Upper curve: Medium curve: Lower...
Open the catalog to page 4QT20.361 36V, 13.3A, THREE PHASE INPUT 8. OUTPUT Output voltage Adjustment range Factory setting Line regulation Load regulation Ripple and noise voltage Output capacitance Guaranteed, multi turn potentiometer At clockwise end position of potentiometer ±0.2%, at full load, cold unit 320 to 552Vac Static value, 0A 13.3A 0A 20Hz to 20MHz, 50Ohm The energy of the bulk capacitor on the input side will be transferred to the output to supply short load peaks. Continuous power capability Output current Output power Short-circuit current At 36V, see Fig. 8-1 At 42V, see Fig. 8-1 36V, continuous 42V,...
Open the catalog to page 5□innefUSIDfU Q-Series 36V, 13.3A, THREE PHASE INPUT Fig. 8-1 Output voltage vs. output current, typ. Fig. 8-2 Bonus time vs. output power Output Voltage Bonus Time Fig. 8-3 BonusPower® recovery time Power <150% / Power Manager I^BonusJ Recovery Time i Time I i Bonus Power disabled i Bonus Power® is available as soon as power comes on and immediately after the end of an output short circuit. Fig. 8-4 BonusPower® after input turn-on Fig. 8-5 BonusPower® after output short All parameters are specified at 36V, 13.3A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Open the catalog to page 6□innefUSIDfU Q-Series 36V, 13.3A, THREE PHASE INPUT Hold-up Time Fig. 9-1 Hold-up time vs. input voltage Fig. 9-2 Shut-down behavior, definitions Hold-up Time Input Voltage Zero Transition Hold-up Time j 10. DC-OK RELAY CONTACT This feature monitors the output voltage, which is produced by the power supply itself. It is independent of a back- fed voltage from a unit which is connected in parallel to the power supply output. Contact closes As soon as the output voltage reaches the adjusted output voltage. Contact opens As soon as the output voltage dips more than 10% below the adjusted output...
Open the catalog to page 7QT20.361 36V, 13.3A, THREE PHASE INPUT 11. EFFICIENCY AND POWER LOSSES Efficiency Power losses Fig. 11-1 Efficiency vs. output current at 36V Fig. 11-2 Losses vs. output current at 36V Power Losses Fig. 11-3 Efficiency vs. input voltage, 36V, 13.3A Output Current Fig. 11-4 Losses vs. input voltage, 36V, 13.3A Power Losses Input Voltage Oct. 2006 / Rev. 1.0 DS-QT20.361-EN All parameters are specified at 36V, 13.3A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 818 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
21 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages