POWER SUPPLY AC 100-240V Wide-range Input Width only 82mm Efficiency up to 93.9% ATEX and IECEx Approved (-A1 Version) -C1 Version with Conformal Coated PC-board 150% (720W) Peak Load Capability Safe HiccupPLUS Overload Mode Easy Fuse Tripping due to High Overload Current Active Power Factor Correction (PFC) Negligible low Inrush Current Surge Short-term Operation down to 60Vac and up to 300Vac Full Power Between -25°C and +60°C DC-OK Relay Contact Quick-connect Spring-clamp Terminals 3 Year Warranty GENERAL DESCRIPTION SHORT-FORM DATA The most outstanding features of this Dimension QSeries DIN-rail power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details. Output voltage Adjustment range Output current With short-term peak power capability of 150% and built-in large sized output capacitors, these features help start motors, charge capacitors and absorb reverse energy and often allow a unit of a lower wattage class to be used. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager, a wide range input voltage design and virtually no input inrush current make installation and usage simple. Diagnostics are easy due to the dry DC-ok contact, a green DC-ok LED and red overload LED. Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation. ORDER NUMBERS Power Supply DC 24V 24 - 28V 20 – 17A 30 – 26A Output power 480W 720W Output ripple < 100mVpp Input voltage AC 100-240V Mains frequency 50-60Hz AC Input current 4.56 / 2.48A Power factor 0.95 / 0.90 AC Inrush current typ. 9 / 7A peak Efficiency 92.4 / 93.9% Losses 39.6 / 31.4W Temperature range -25°C to +70°C Derating 12W/°C Hold-up time typ. 32 / 51ms Dimensions 82x124x127mm 24-28V Standard unit ATEX approved unit Conformal coated unit Wall mount bracket Side mount bracket Redundancy module Redundancy module Oct. 2013 / Rev. 2.2 DS-QS20.241-EN All parameters are specified at 24V, 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included....
Open the catalog to page 21. INTENDED USE This device is designed for installation in an enclosure and is intended for the general use such as in industrial control, office, communication, and instrumentation equipment. Do not use this power supply in equipment, where malfunction may cause severe personal injury or threaten human life. This device is designed for use in hazardous, non-hazardous, ordinary or unclassified locations. 2. INSTALLATION REQUIREMENTS This device may only be installed and put into operation by qualified personnel. This device does not contain serviceable parts. The tripping of an internal...
Open the catalog to page 33. AC-INPUT AC input AC input range Allowed voltage L or N to earth Input frequency Turn-on voltage Shut-down voltage Input current Power factor *) Crest factor **) Start-up delay Rise time Turn-on overshoot suitable for TN-, TT- and IT mains networks continuous operation full power for 200ms, no damage between 0 and 85Vac < 500ms continuous, IEC 62103 ±6% steady-state value, see Fig. 3-1 steady-state value, see Fig. 3-1 dynamic value AC 120V 4.56A 0.95 1.7 610ms 80ms 85ms 100mV *) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. **) The...
Open the catalog to page 44. DC-INPUT DC input DC input range DC input current Allowed Voltage L/N to Earth Turn-on voltage Shut-down voltage 110Vdc, at 24V, 20A IEC 62103 steady state value steady state value Instructions for DC use: a) Use a battery or similar DC source. For other sources contact PULS b) Connect +pole to L and –pole to N. c) Connect the PE terminal to an earth wire or to the machine ground. 5. INPUT INRUSH CURRENT An active inrush limitation circuit limits the input inrush current after turn-on of the input voltage and after short input voltage interruptions. The charging current into EMI...
Open the catalog to page 56. OUTPUT Output voltage Adjustment range Output power Factory setting Line regulation Load regulation Ripple and noise voltage Output current Short-circuit current Output capacitance BonusPower® time BonusPower® recovery time Overload behaviour guaranteed at clockwise end position of potentiometer ±0.2%, at full load, cold unit 60-300Vac static value, 0A 20A 20Hz to 20MHz, 50Ohm continuously available at 24V, see Fig. 6-1 continuously available at 28V, see Fig. 6-1 short term available BonusPower® *), at 24V, for typical 4s, see Fig. 6-1 short term available BonusPower® *), at 28V, for...
Open the catalog to page 6□innefUSIOfU Q-Series 24V, 20A, SINGLE PHASE INPUT Peak current capability (up to several milliseconds) The power supply can deliver a peak current which is higher than the specified short term current. This helps to start current demanding loads or to safely operate subsequent circuit breakers. The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will be discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 22.2. Peak current voltage dips typ. from 24V to 20V at 40A for 50ms, resistive load...
Open the catalog to page 7All PULS GmbH catalogs and technical brochures
-
FPT500 series
35 Pages
-
FPS300 series
32 Pages
-
CD10.242
29 Pages
-
DECENTRALIZED POWER SUPPLIES
9 Pages
-
PIANO
5 Pages
-
PIANO PIC
2 Pages
-
selection guide 2018
31 Pages
-
PULS CP
7 Pages
-
Selection Guide 2015/2016
25 Pages
-
CP10.241
27 Pages
-
CP10.241-S1
27 Pages
-
PIC120.241D
22 Pages
-
CP10.121
26 Pages
-
SLR01
2 Pages
-
SLZ14
2 Pages
-
SLZ12
2 Pages
-
SLZ11
2 Pages
-
SLZ02
2 Pages
-
SLR10.100
2 Pages
-
SL40.301
2 Pages
-
SL40.300
2 Pages
-
SL30.300
2 Pages
-
SL20.303
2 Pages
-
SL20.310
2 Pages
-
SL20.301
2 Pages
-
SL20.300
2 Pages
-
SL10.309
2 Pages
-
SL10.305
4 Pages
-
SL10.300
2 Pages
-
SL5.300
2 Pages
-
SL30.100
2 Pages
-
SL20.115
2 Pages
-
SL20.113
2 Pages
-
SL20.112
2 Pages
-
SL20.111
2 Pages
-
SL20.110
2 Pages
-
SL20.101
2 Pages
-
SL20.100
2 Pages
-
SL10.106
2 Pages
-
SL10.105
2 Pages
-
SL10.10
2 Pages
-
SL10.104
2 Pages
-
SL10.101
2 Pages
-
SL10.100
2 Pages
-
SL5.105
2 Pages
-
SL5.102
2 Pages
-
SL5.100
2 Pages
-
SL4.100
2 Pages
-
SL2.103
2 Pages
-
SL2.100
2 Pages
-
ML100.200
2 Pages
-
ML90.200
2 Pages
-
ML100.105
2 Pages
-
ML100.102
2 Pages
-
ML100.100
2 Pages
-
ML95.100
2 Pages
-
ML70.100
2 Pages
-
ML60.121
23 Pages
-
ML50.111
2 Pages
-
ML50.109
20 Pages
-
ML50.105
2 Pages
-
ML50.102
2 Pages
-
ML50.101
2 Pages
-
ML50.100
20 Pages
-
ML30.241
23 Pages
-
ML30.106
2 Pages
-
ML30.102
2 Pages
-
ML30.101
2 Pages
-
ML30.100
2 Pages
-
ML15.241
23 Pages
-
ML15.121
23 Pages
-
ML15.051
22 Pages
-
YRM2.DIODE
19 Pages
-
YR80.241
17 Pages
-
YR40.241
17 Pages
-
YR2.DIODE
19 Pages
-
XT40.722
19 Pages
-
XT40.721
19 Pages
-
XT40.482
20 Pages
-
XT40.481
20 Pages
-
XT40.362
20 Pages
-
XT40.361
20 Pages
-
XT40.242
20 Pages
-
XT40.241
20 Pages
-
ZM15.SIDE
2 Pages
-
ZM14.SIDE
2 Pages
-
ZM13.SIDE
2 Pages
-
ZM12.SIDE
2 Pages
-
ZM11.SIDE
2 Pages
-
ZM2.WALL
3 Pages
-
ZM1.WALL
2 Pages
-
ZM1.UBC10
2 Pages
-
UZS24.100
3 Pages
-
UF20.481
13 Pages
-
UF20.241
11 Pages
-
UZO12.26
2 Pages
-
UZO12.07
9 Pages
-
UZK12.261
8 Pages
-
UZK12.071
9 Pages
-
UBC10.241-N1
23 Pages
-
UBC10.241
23 Pages
-
UB10.245
24 Pages
-
UB10.242
21 Pages
-
UB10.241
23 Pages
-
QT40.481
28 Pages
-
QT40.241
28 Pages
-
QT20.481
23 Pages
-
QT20.361
23 Pages
-
QT20.241-C1
23 Pages
-
QT20.241
23 Pages
-
QTD20.241
22 Pages
-
QS10.481-D1
27 Pages
-
QS10.241-D1
27 Pages
-
QS40.484
28 Pages
-
QS40.244
28 Pages
-
QS20.481
25 Pages
-
QS20.361
25 Pages
-
QS20.244
25 Pages
-
QS20.241-C1
26 Pages
-
QS20.241
26 Pages
-
QS10.481
27 Pages
-
QS10.DNET
22 Pages
-
QS10.301
26 Pages
-
QS10.241-C1
27 Pages
-
QS10.241-A1
27 Pages
-
QS10.241
28 Pages
-
QS10.121
26 Pages
-
QS5.DNET
21 Pages
-
QS5.241-A1
26 Pages
-
QS5.241
26 Pages
-
QS3.241
25 Pages
-
PISA11.CLASS2
19 Pages
-
PISA11.206212
23 Pages
-
PISA11.203206
23 Pages
-
PISA11.410
23 Pages
-
PISA11.406
23 Pages
-
PISA11.404
23 Pages
-
PISA11.403
23 Pages
-
PISA11.402
23 Pages
-
PISA11.401
23 Pages
-
PIC240.241D
21 Pages
-
PIC120.241C
21 Pages
-
PAS395
14 Pages
-
CT10.481
22 Pages
-
CT10.241
22 Pages
-
CT5.241
21 Pages
-
CT5.121
21 Pages
-
CS10.481
20 Pages
-
CS10.244
21 Pages
-
CS10.243
19 Pages
-
CS10.242
19 Pages
-
CS10.241-S1
20 Pages
-
CS10.241
20 Pages
-
CS5.244
20 Pages
-
CS5.243
19 Pages
-
CS5.241-S1
20 Pages
-
CS5.241-C1
20 Pages
-
CS5.241
20 Pages
-
CS3.241
21 Pages
-
CPS20.241-C1
26 Pages
-
CPS10.241
26 Pages
-
CP10.242
27 Pages
-
CD5.243
22 Pages
-
CD5.242
22 Pages
-
CD5.241-S1
23 Pages
-
CD5.241-L1
21 Pages
-
CD5.241
22 Pages
-
CD5.121
22 Pages
-
PIC120.242C
21 Pages
-
PIC240.241C
20 Pages
-
QS40.361
27 Pages
-
QS40.481
28 Pages
-
QT40.361
27 Pages
-
UB20.241
31 Pages
-
UZK24.071
9 Pages
-
UZK24.121
9 Pages
-
UZO24.071
9 Pages
-
UZO24.121
9 Pages
-
UC10.241
27 Pages
-
UC10.242
27 Pages
-
YR40.242
17 Pages
-
YR40.245
18 Pages
-
YR40.482
17 Pages
-
YR80.242
17 Pages
-
SLA3.100
4 Pages
-
SLA4.100
4 Pages
-
SLA8.100
4 Pages
-
SLA8.300
4 Pages
-
SLAD4.100
4 Pages
-
SLD2.100
2 Pages
-
SLR02
2 Pages
-
SLR2.100
2 Pages
-
SLR5.100
2 Pages
-
SLR10.108
2 Pages
-
SLV20.200
4 Pages
-
SLZ10-14
2 Pages
-
ML60.122
23 Pages
-
ML60.241
23 Pages
-
ML60.242
23 Pages
-
ML120.241
22 Pages
-
ML120.244
21 Pages
-
ML120.CLASS2
19 Pages
-
MLY02.100
16 Pages
-
MLY10.241
16 Pages
-
ZM3.WALL
1 Pages
-
CPS20.481-D1
25 Pages
-
CPS20.241-D1
25 Pages
-
Selection Guide 2013
19 Pages
-
QS40.241, QS40.241-A1
28 Pages
-
CPS20.241
25 Pages
-
CPS20.361
25 Pages
-
CPS20.481
25 Pages
-
CPS20.121
25 Pages
Archived catalogs
-
PIC120.241D
21 Pages
-
Products 2009-2010
28 Pages
-
Products 2007
34 Pages