POWER SUPPLY AC 200-240V Regional Input Cost Optimized without Compromising Quality or Reliability. Width only 39mm Efficiency up to 90.5% Low No-load Power Losses Full Power Between -10°C and +55°C DC-OK Relay Contact Included 3 Year Warranty GENERAL DESCRIPTION SHORT-FORM DATA These PIANO series units are extraordinarily compact, industrial grade power supplies that focus on the essential features needed in today’s industrial applications. The excellent cost/performance ratio presents many new and exciting opportunities without compromising quality or reliability. Output voltage Adjustment range Output current The mechanically robust housing is made of a highgrade, reinforced molded material, which permits the units to be used in surrounding temperatures up to 70°C. Since typical industrial applications do not require multiple mains inputs, the reduction to a regional input voltage range (AC 200-240V) simplifies the circuitry and has significant advantages for reliability, efficiency and cost. The addition of a DC-OK signal makes the unit suitable for many industry applications such as: process, automation and many other critical applications where preventive function monitoring can help to avoid long downtimes. ORDER NUMBERS Power Supply DC 24V 24 - 28V 5A 3.1A 4.3A 2.7A Output power 120W 75W Output ripple < 100mVpp AC Input voltage AC 200-240V Mains frequency 50-60Hz AC Input current 1.12A Power factor 0.54 AC Inrush current 28A peak Efficiency 90.5% Losses 12.6W Temperature range -10°C to +70°C Derating 3W/°C Hold-up time 33ms Dimensions 39x124x124mm Weight 350g / 0.77lb MARKINGS 24-28V Standard unit with DC-OK contact 24-28V Standard unit without DC-OK contact Redundancy module Buffer Module Jan. 2015 / Rev. 1.3 DS-PIC120.241C-EN All parameters are specified at 24V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included. E.g.:...
Open the catalog to page 21. INTENDED USE This device is designed for installation in an enclosure and is intended for the general professional use such as in industrial control, office, communication, and instrumentation equipment. Do not use this power supply in equipment, where malfunction may cause severe personal injury or threaten human life. 2. INSTALLATION REQUIREMENTS This device may only be installed and put into operation by qualified personnel. This device does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect. If damage or malfunction should occur during installation...
Open the catalog to page 33. AC-INPUT AC input AC input range External input protection nom. AC 200-240V suitable for TN-, TT- and IT mains networks min. 180-264Vac continuous operation min. 264-300Vac < 500ms max. 300Vac continuous, IEC 62103 nom. 50–60Hz ±6% typ. 162Vac steady-state value, see Fig. 3-1 typ. 100Vac at 24V 0A, steady-state value, see Fig. 3-1 typ. 130Vac at 24V 5A, steady-state value, see Fig. 3-1 See recommendations in chapter 22.3. Input current Power factor*) Crest factor**) Start-up delay Rise time Allowed voltage L or N to earth Input frequency Turn-on voltage Shut-down voltage Turn-on overshoot...
Open the catalog to page 44. DC-INPUT Do not operate this power supply with DC-input voltage. 5. INPUT INRUSH CURRENT A NTC inrush limiter limits the input inrush current after turn-on of the input voltage. Inrush current Inrush energy*) *) 40°C ambient, cold start 40°C ambient, cold start 25°C ambient, cold start 40°C ambient, cold start The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Fig. 5-1 Input inrush current, typical behavior 230Vac input, 24V 5A output, 25°C ambient Fig. 5-2 Input inrush current, zoom into first peak 230Vac input, 24V 5A output, 25°C...
Open the catalog to page 56. OUTPUT Output voltage Adjustment range Factory settings Line regulation Load regulation Ripple and noise voltage Output current Output power Overload behaviour Short-circuit current Output capacitance *) **) guaranteed at clockwise end position of potentiometer ±0.2%, at full load, cold unit 180-264Vac static value, 0A 5A; see Fig. 6-1 20Hz to 20MHz, 50Ohm at 24V, ambient temperature <55°C, see Fig. 6-1 at 24V, ambient temperature <70°C, see Fig. 6-1 at 28V, ambient temperature <55°C, see Fig. 6-1 at 28V, ambient temperature <70°C, see Fig. 6-1 ambient temperature <55°C ambient temperature...
Open the catalog to page 67. HOLD-UP TIME Hold-up Time Fig. 7-1 Hold-up time vs. input voltage Hold-up Time Fig. 7-2 Shut-down behavior, definitions Zero Transition Output Voltage Hold-up Time 264Vac 8. DC-OK RELAY CONTACT This feature is available only for the PIC120.241C unit and monitors the output voltage on the output terminals. Threshold voltage Contact closes Contact opens Contact ratings Isolation voltage typ. 21.4V (fixed) As soon as the output voltage reaches 21.4V. As soon as the output voltage falls below 21.4V. max. 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A resistive load min. 1mA at 5Vdc min. permissible load See...
Open the catalog to page 79. EFFICIENCY AND POWER LOSSES Efficiency Average efficiency*) Power losses The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25% of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100% of the nominal load for the rest of the time. Fig. 9-1 Efficiency vs. output current at 24V, typ. Fig. 9-2 Losses vs. output current at 24V, typ. Power Losses Output Current 10. LIFETIME EXPECTANCY AND MTBF Lifetime expectancy*) MTBF**) SN 29500, IEC 61709...
Open the catalog to page 818 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
21 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages