POWER SUPPLY AC 380-480V Wide-range Input Input Fuses Already Included Requires only Two Legs of a 3-Phase System Width only 40mm Efficiency up to 90.4% 20% Output Power Reserves Input -Transient Blanking Circuit Included Minimal Inrush Current Surge Full Power Between -25°C and +60°C 3 Year Warranty GENERAL DESCRIPTION SHORT-FORM DATA The Dimension C-Series are cost optimized power supplies without compromising quality, reliability and performance. The C-Series is part of the DIMENSION power supply family. The most outstanding features of CT5.241 are the high efficiency, electronic inrush current limitation, active input transient filter and wide operational temperature range, the small size and other technological design concepts. Output voltage Adjustment range Output current The C-Series includes all the essential basic functions. The devices have a power reserve of 20% included, which may even be used continuously at temperatures up to +45°C. The CT5.241 utilizes only 2 legs of a 3phase system which saves wiring and installation costs. Furthermore, this allows a smaller unit without compromising the size of the terminals. Due to the low power consumption, an unbalancing of the individual phases is not expected. ORDER NUMBERS DC 24V 24-28V 5 – 4.3A 6 – 5.2A Output power 120W 144W Output ripple < 50mVpp Input voltage AC 380-480V Mains frequency 50-60Hz AC Input current 0.75 / 0.68A Power factor 0.45 / 0.43 AC Inrush current typ. 4A peak Efficiency 90.4 / 90.0% Losses 12.7 / 13.3W Temperature range -25°C to +70°C Derating 3W/°C Hold-up time typ. 27 / 48ms Dimensions 40x124x117mm Power Supply Wall mount bracket Side mount bracket Decoupling module Buffer unit Jan. 2010 / Rev. 1.1 DS-CT5.241-EN All parameters are specified at 24V, 5A, 400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1The information presented in this document is believed to be accurate and reliable and may change without notice. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included. E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V) A figure with the unit (Vac)...
Open the catalog to page 21. INTENDED USE This device is designed for installation in an enclosure and is intended for the general use such as in industrial control, office, communication, and instrumentation equipment. Do not use this power supply in aircrafts, trains and nuclear equipment where malfunction may cause severe personal injury or threaten human life. This device is designed for use in non-hazardous, ordinary or unclassified locations. Do not use in hazardous location areas. 2. INSTALLATION REQUIREMENTS This device may only be installed and put into operation by qualified personnel. This device does not contain...
Open the catalog to page 3Input current Power factor *) Start-up delay Rise time Turn-on overshoot The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. Fig. 3-1 Input voltage range Rated input range Input Voltage Fig. 3-2 Turn-on behavior, definitions Output Voltage Rise Time Fig. 3-3 Input current vs. output load at 24V Input Current, typ. Start-up delay Allowed Voltage Phase to Earth Input frequency Turn-on voltage Shut-down voltage TN, TT, IT-mains networks, grounding of one phase is allowed except for UL508 applications continuous operation, no damage between 0 and 323Vac...
Open the catalog to page 44. DC-INPUT DC input DC input range Allowed Voltage Line to Earth DC input current Turn-on voltage Shut-down voltage Power Supply AC FUSE FUSE continuous operation IEC 62103 450Vdc / 780Vdc, 24V, 5A steady state value steady state value Instructions for DC use: a) Use a battery or similar DC source. For other sources contact PULS b) Connect +pole to L1 and –pole to L2. c) Use appropriate external fuses in the + and – lines which are suitable for the DC-voltage. d) Connect the PE terminal to a earth wire or to the machine ground. e) DC-operation is not included in the UL approval. Additional testing...
Open the catalog to page 56. OUTPUT Output voltage Adjustment range Factory setting Line regulation Load regulation Ripple and noise voltage Output capacitance Output current Output power Short-circuit current guaranteed at clockwise end position of potentiometer ±0.2%, at full load, cold unit 323-576Vac static value, 0A 5A 20Hz to 20MHz, 50Ohm at 24V, ambient < 45°C, see Fig. 6-1 at 24V, ambient < 60°C, see Fig. 6-1 at 28V, ambient < 45°C, see Fig. 6-1 at 28V, ambient < 60°C, see Fig. 6-1 for ambient temperatures < 45°C for ambient temperatures < 60°C continuous current, short circuit impedance 200mOhm continuous current,...
Open the catalog to page 67. HOLD-UP TIME Hold-up Time Fig. 7-1 Hold-up time vs. input voltage Fig. 7-2 Shut-down behavior, definitions Input Voltage Hold-up Time Input Voltage Output Voltage Jan. 2010 / Rev. 1.1 DS-CT5.241-EN All parameters are specified at 24V, 5A, 400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 7□innerusiom c-Series 24V, 5A, TWO-PHASE INPUT I 8. EFFICIENCY AND POWER LOSSES_ *) The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25% of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100% of the nominal load for the rest of the time. Fig. 8-3 Efficiency vs. input voltage at 24V, Fig. 8-4 Losses vs. input voltage at 24V, 5A, Power Losses All parameters are specified at 24V, 5A, 400Vac, 25°C ambient and after a 5 minutes run-in time unless...
Open the catalog to page 818 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
20 Pages
21 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages