
CS10.244 24V, 10A, SINGLE PHASE INPUT AC 200-240V Single-Phase Input Efficiency up to 91.3% Width only 60mm 20% Output Power Reserves Full Output Power up to +60°C 3 Year Warranty The Dimension C-Series are cost optimized power supplies without compromising quality, reliability and performance. The C-Series is part of the Dimension power supply family, existing alongside the high featured Q-series. Output voltage Adjustment range Output current The C series includes all the essential basic functions and the devices have a power reserve of 20%. This extra current may even be used continuously at temperatures up to +45°C. The most important features are the small size, the high efficiency and the wide temperature range. The CS10.244 is a device for 200-240V mains only. This supports regional applications and offers additional cost savings without sacrificing functionality. Spring-clamp terminals C-Series Related products CS5.241 Less power PFC inductor only 100-120V only 200-240V 48V output 4. MARKINGS Standard unit 3. ORDER NUMBERS Power Supply CS10.244 DC 24V 24 - 28V 10 – 8,6A 12 – 10,3A Output power 240W 288W Output ripple < 50mVpp Input voltage AC 200-240V Mains frequency 50-60Hz AC Input current typ. 2.2A Power factor typ. 0.52 AC Inrush current typ. 48A peak DC Input 210-375Vdc Efficiency typ. 91.3% Losses typ. 23.4W Temperature range 0°C to +70°C Derating 6W/°C Hold-up time typ. 45ms Dimensions 60x124x117mm Buffer module Redundancy module Wall mount bracket Side mount bracket Marine, pending Sept. 2006 / Rev. 1.0 DS-CS10.244-EN / All parameters are specified at 24V, 10A, 230Vac and 25°C ambient unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1CS10.244 24V, 10A, SINGLE PHASE INPUT INTENDED USE The power supply shall only be installed and put into operation by qualified personnel. This power supply is designed for installation in an enclosure and is intended for the general use, such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document...
Open the catalog to page 2CS10.244 24V, 10A, SINGLE PHASE INPUT 5. AC-INPUT AC input AC input range Input frequency Input current Power factor *) Crest factor **) Start-up delay Rise time Turn-on overshoot Turn-on voltage Shut-down voltage at 24V, 10A see Fig. 5-3 at 24V, 10A see Fig. 5-1 at 24V, 10A see Fig. 5-2 0mF, 24V, 10A, see Fig. 5-2 10mF, 24V, 10A, see Fig. 5-2 see Fig. 5-2 steady-state value, see Fig. 5-1 steady-state value, see Fig. 5-1 The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. The crest factor is the mathematical ratio of the peak value to the RMS value...
Open the catalog to page 3CS10.244 24V, 10A, SINGLE PHASE INPUT 6. INPUT INRUSH CURRENT SURGE A NTC inrush limitation circuitry limits the input inrush current after turn-on of the input voltage. The charging current into EMI suppression capacitors is disregarded in the first milliseconds after switch-on. Inrush current Inrush energy at +40°C ambient, first start at +40°C ambient, first start at +40°C ambient, first start Fig. 6-1 Input inrush current, typical behavior Input: Output: Ambient: Upper curve: Medium curve: Lower curve: Time scale: Input current 20A / DIV Input voltage 200V / DIV Output voltage 10V / DIV 20ms...
Open the catalog to page 4CS10.244 24V, 10A, SINGLE PHASE INPUT 8. HOLD-UP TIME Hold-up Time Fig. 8-1 Hold-up time vs. input voltage Hold-up Time a) 24V 5A typ. 120ms b) 24V 5A min. c) 24V 10A typ. 100 d) 24V 10A min. e) 24V 12A min. Fig. 8-2 Shut-down behavior, definitions Zero Transition Intput Voltage Output Voltage Hold-up Time Note: At no load, the hold-up time can be up to several seconds. The green DC-ok lamp is on during this time. Sept. 2006 / Rev. 1.0 DS-CS10.244-EN / All parameters are specified at 24V, 10A, 230Vac and 25°C ambient unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 5□innerusiofu c-series 24V, 10A, SINGLE PHASE INPUT Output voltage Adjustment range Factory setting at clockwise end position of potentiometer ±0.2%, at full load, cold unit Line regulation Load regulation Ripple and noise voltage Output capacitance Output current Output power Short-circuit current load impedance lOOmOhm, see Fig. 9-1 Fig. 9-1 Output voltage vs. output current, typ. Output Voltage Peak current capability (up to several ms) The power supply can deliver a peak current which is higher than the specified short term current. This helps to start current demanding loads or to safely...
Open the catalog to page 6CS10.244 24V, 10A, SINGLE PHASE INPUT 10. EFFICIENCY AND POWER LOSSES Efficiency Power losses Fig. 10-1 Efficiency vs. output current at 24V Efficiency Fig. 10-2 Losses vs. output current at 24V Power Losses Fig. 10-3 Efficiency vs. input voltage, 24V, 10A Output Current Fig. 10-4 Losses vs. input voltage, 24V, 10A Power Losses Input Voltage Input Voltage Sept. 2006 / Rev. 1.0 DS-CS10.244-EN / All parameters are specified at 24V, 10A, 230Vac and 25°C ambient unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 7CS10.244 24V, 10A, SINGLE PHASE INPUT 11. FUNCTIONAL DIAGRAM Fig. 11-1 Functional diagram Output Voltage Regulator Input Rectifier & Inrush Limiter (NTC) Input Fuse & Input Filter Power Converter Output Filter Output OverVoltage Protection 12. RELIABILITY AC 100V Lifetime expectancy The Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours. Lifetime expectancy is calculated according to the capacitor’s manufacturer specification....
Open the catalog to page 8CS10.244 24V, 10A, SINGLE PHASE INPUT 13. FRONT SIDE AND USER ELEMENTS Fig. 13-1 Front side Output voltage potentiometer Open the flap to tune the output voltage. Factory set: 24.1V Output Terminals Screw terminals + - Positive output Negative (return) output Dual pins per pole DC-on lamp (green) On when the voltage on the output terminals is > 21 V Input Terminals Screw terminals N … Neutral input L … Line (hot) input ... PE (Protective Earth) input 14. TERMINALS AND WIRING Type Solid wire Stranded wire American wire gauge Ferrules Wire stripping length Screwdriver Recommended tightening torque...
Open the catalog to page 918 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages