
CS10.242 24V, 10A, SINGLE PHASE INPUT AC 100-120 / 200-240V Auto Select Input PFC Inductor included fulfills EN 61000-3-2 Efficiency up to 91.2% Width only 60mm 20% Output Power Reserves (short term) Full Output Power Between -25°C and +60°C Minimal Inrush Current Surge 3 Year Warranty The Dimension C-Series are cost optimized power supplies without compromising quality, reliability and performance. The C-Series is part of the Dimension power supply family, existing alongside the high featured Q-series. Output voltage Adjustment range Output current Output power The C series includes all the essential basic functions and the devices have a power reserve of 20%. The most important features are the small size, the high efficiency and the wide temperature range. The specialty of the CS10.242 is the PFC filter with which the harmonic standard EN61000-3-2 is fulfilled. The Auto-select input makes worldwide installation and usage very simple. Defects or system failures caused by wrongly set switches can not occur. Spring-clamp terminals C-Series Related products CS5.241 Less power PFC inductor only 100-120V only 200-240V 48V output < 50mVpp AC 100-120 / 200-240V Mains frequency 50-60Hz AC Input current typ. 3.73 / 2.0A Power factor typ. 0.59 / 0.57 AC Inrush current typ. 3A peak DC Input not allowed Efficiency typ. 91.0 / 91.2% Losses typ. 23.7 / 23.2W Temperature range -25°C to +70°C Derating 6W/°C Hold-up time typ. 46 / 42ms Dimensions 60x124x117mm 3. ORDER NUMBERS Power Supply CS10.242 Output ripple Input voltage 4. MARKINGS Standard unit Wall mount bracket Side mount bracket Redundancy module Marine, pending xx 200y Rev. 1.1 DS-CS10.242-EN All parameters are specified at 24V, 10A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1CS10.242 24V, 10A, SINGLE PHASE INPUT INTENDED USE The power supply shall only be installed and put into operation by qualified personnel. This power supply is designed for installation in an enclosure and is intended for the general use, such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document...
Open the catalog to page 2CS10.242 24V, 10A, SINGLE PHASE INPUT Input frequency Input current Power factor *) Crest factor **) Start-up delay Rise time AC input AC input range Turn-on overshoot Turn-on voltage Shut-down voltage 100-120V range, continuous operation 200-240V range, continuous operation Short term or with output derating < 0.5s ±6% AC 120V 3.73A 0.59 2,83 800ms 35ms 75ms 100mV 82Vac 75Vac at 24V, 10A see Fig. 5-3 at 24V, 10A see Fig. 5-1 at 24V, 10A see Fig. 5-2 0mF, 24V, 10A, see Fig. 5-2 10mF, 24V, 10A, see Fig. 5-2 see Fig. 5-2 steady-state value, see Fig. 5-1 steady-state value, see Fig. 5-1 The power...
Open the catalog to page 3□innefUSIOfU C-Series 24V, 10A, SINGLE PHASE INPUT I 6. INPUT INRUSH CURRENT SURGE An active inrush limitation circuitry limits the input inrush current after turn-on of the input voltage. The charging current into EMI suppression capacitors is disregarded in the first milliseconds after switch-on. Inrush current Inrush energy Fig. 6-1 Input inrush current, typical behavior Upper curve: Medium curve: Lower curve: Time scale: Start-up delay = Inrush delay Hold-up Time Fig. 7-1 Hold-up time vs. input voltage Fig. 7-2 Shut-down behavior, definitions Hold-up Time Zero Transition Hold-up Time Note:...
Open the catalog to page 4□innefUSIOfU C-Series 24V, 10A, SINGLE PHASE INPUT Output voltage Adjustment range Factory setting at clockwise end position of potentiometer ±0.2%, at full load, cold unit Line regulation Load regulation Ripple and noise voltage Output capacitance Output current nom. 12A at 24V, max. 1 minute every 10 minutes in an average nom. 10.3A at 28V, max. 1 minute every 10 minutes in an average Output power nom. 288W max. 1 minute every 10 minutes in an average Short-circuit current load impedance lOOmOhm, see Fig. 8-1 Fig. 8-1 Output voltage vs. output current, typ. Output Voltage Peak current capability...
Open the catalog to page 5CS10.242 24V, 10A, SINGLE PHASE INPUT 9. EFFICIENCY AND POWER LOSSES Efficiency Power losses Fig. 9-1 Efficiency vs. output current at 24V Efficiency Fig. 9-2 Losses vs. output current at 24V Power Losses Output Current Fig. 9-3 Efficiency vs. input voltage, 24V, 10A Output Current Fig. 9-4 Losses vs. input voltage, 24V, 10A Power Losses Input Voltage xx 200y Rev. 1.1 DS-CS10.242-EN All parameters are specified at 24V, 10A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 6CS10.242 24V, 10A, SINGLE PHASE INPUT 10. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram Output Voltage Regulator Input Fuse & Input Filter Input Rectifier & Inrush Limiter Power Converter Output Filter Output OverVoltage Protection 11. RELIABILITY AC 100V Lifetime expectancy MTBF SN 29500, IEC 61709 MTBF MIL HDBK 217F The Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours. Lifetime expectancy is calculated according to the...
Open the catalog to page 7CS10.242 24V, 10A, SINGLE PHASE INPUT 12. FRONT SIDE AND USER ELEMENTS Fig. 12-1 Front side Output Terminals Screw terminals + - Output voltage potentiometer Open the flap to tune the output voltage. Factory set: 24.1V Positive output Negative (return) output Dual pins per pole DC-on lamp (green) On when the voltage on the output terminals is > 21 V Input Terminals Screw terminals N … Neutral input L … Line (hot) input ... PE (Protective Earth) input 13. TERMINALS AND WIRING Type Solid wire Stranded wire American wire gauge Ferrules Wire stripping length Screwdriver Recommended tightening torque...
Open the catalog to page 818 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
21 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages