AC 100-120 / 200-240V Auto Select Input Efficiency up to 91.6% Width only 60mm 20% Output Power Reserves Full Output Power Between -25°C and +60°C Minimal Inrush Current Surge 3 Year Warranty The Dimension C-Series are cost optimized power supplies without compromising quality, reliability and performance. The C-Series is part of the Dimension power supply family, existing alongside the high featured Q-series. Output voltage Adjustment range Output current The C series includes all the essential basic functions and the devices have a power reserve of 20%. This extra current may even be used continuously at temperatures up to +45°C. The most important features are the small size, the high efficiency and the wide temperature range. The Auto-select input makes worldwide installation and usage very simple. Defects or system failures caused by wrongly set switches can not occur. Spring-clamp terminals C-Series Related products CS5.241 Less power PFC inductor only 100-120V only 200-240V 48V output 3. ORDER NUMBERS Power Supply CS10.241 CS10.241-S1 DC 24V 24 - 28V 10 – 8,6A 12 – 10,3A Output power 240W 288W Output ripple < 50mVpp Input voltage AC 100-120 / 200-240V Mains frequency 50-60Hz AC Input current typ. 3.73 / 2.23A Power factor typ. 0.59 / 0.51 AC Inrush current typ. 3A peak DC Input not allowed Efficiency typ. 91.0 / 91.6% Losses typ. 23.7 / 22.0W Temperature range -25°C to +70°C Derating 6W/°C Hold-up time typ. 46 / 47ms Dimensions 60x124x117mm 4. MARKINGS Standard unit Quick-connect springclamp terminals Wall mount bracket Side mount bracket Redundancy module Marine, pending August 2006 / Rev. 1.1 DS-CS10.241-EN / All parameters are specified at 24V, 10A, 230Vac and 25°C ambient unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1INTENDED USE The power supply shall only be installed and put into operation by qualified personnel. This power supply is designed for installation in an enclosure and is intended for the general use, such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document uses the term “earth” which is the same...
Open the catalog to page 2Input frequency Input current Power factor *) Crest factor **) Start-up delay Rise time AC input AC input range Turn-on overshoot Turn-on voltage Shut-down voltage 100-120V range, continuous operation 200-240V range, continuous operation Short term or with output derating < 0.5s ±6% AC 120V 3.73A 0.59 2,83 800ms 35ms 75ms 100mV 80Vac 75Vac at 24V, 10A see Fig. 5-3 at 24V, 10A see Fig. 5-1 at 24V, 10A see Fig. 5-2 0mF, 24V, 10A, see Fig. 5-2 10mF, 24V, 10A, see Fig. 5-2 see Fig. 5-2 steady-state value, see Fig. 5-1 steady-state value, see Fig. 5-1 The power factor is the ratio of the true (or...
Open the catalog to page 36. INPUT INRUSH CURRENT SURGE An active inrush limitation circuitry limits the input inrush current after turn-on of the input voltage. The charging current into EMI suppression capacitors is disregarded in the first milliseconds after switch-on. Inrush current Inrush energy Fig. 6-1 Input inrush current, typical behavior Output Voltage Upper curve: Medium curve: Lower curve: Time scale: Input Voltage Start-up delay = Inrush delay Input: Output: Ambient: Input Current Input current 10A / DIV Input voltage 500V / DIV Output voltage 20V / DIV 100ms / DIV 7. HOLD-UP TIME Hold-up Time Fig. 7-1 Hold-up...
Open the catalog to page 4□innerusiofu c-series 24V, 10A, SINGLE PHASE INPUT Output voltage Adjustment range Factory setting at clockwise end position of potentiometer ±0.2%, at full load, cold unit Line regulation Load regulation Ripple and noise voltage Output capacitance Output current Output power Short-circuit current load impedance lOOmOhm, see Fig. 8-1 Fig. 8-1 Output voltage vs. output current, typ. Output Voltage Peak current capability (up to several ms) The power supply can deliver a peak current which is higher than the specified short term current. This helps to start current demanding loads or to safely...
Open the catalog to page 59. EFFICIENCY AND POWER LOSSES Efficiency Power losses Fig. 9-1 Efficiency vs. output current at 24V Efficiency Fig. 9-2 Losses vs. output current at 24V Power Losses Fig. 9-3 Efficiency vs. input voltage, 24V, 10A Output Current Fig. 9-4 Losses vs. input voltage, 24V, 10A Power Losses Input Voltage August 2006 / Rev. 1.1 DS-CS10.241-EN / All parameters are specified at 24V, 10A, 230Vac and 25°C ambient unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 610. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram Output Voltage Regulator Input Rectifier & Inrush Limiter Input Fuse & Input Filter Power Converter Output Filter Output OverVoltage Protection 11. RELIABILITY AC 100V Lifetime expectancy The Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours. Lifetime expectancy is calculated according to the capacitor’s manufacturer specification. The prediction model allows a calculation...
Open the catalog to page 7□innerusiofu c-series 24V, 10A, SINGLE PHASE INPUT I 12. FRONT SIDE AND USER ELEMENTS Output Terminals - Screw terminals Negative (return) output Dual pins per pole Output voltage potentiometer 'Open the flap to tune the output voltage. DC-on lamp (green) On when the voltage on the output Input Terminals Screw terminals (Spring-clamp terminals ®... PE (Protective Earth) input Screw terminals (CS10.241); Spring-clamp terminals (CS10.241-S1) Solid wire Stranded wire American wire gauge Wire stripping length Recommended tightening torque 3.5mm slotted or Pozidrive No 2 (only for screw terminals)...
Open the catalog to page 814. EMC The CE mark is in conformance with EMC guideline 89/336/EEC and 93/68/EEC and the low-voltage directive (LVD) 73/23/EWG. A detailed EMC Report is available on request. EMC Immunity Electrostatic discharge Electromagnetic RF field Fast transients (Burst) Surge voltage on input Surge voltage on output Conducted disturbance Mains voltage dips Voltage interruptions Input voltage swells Powerful transients EN 61000-4-11 PULS internal standard VDE 0160 Contact discharge Air discharge 80MHz-1GHz Input lines Output lines L N N/L PE + +/PE 0,15-80MHz 0% of 100Vac 40% of 100Vac 70% of 100Vac 0%...
Open the catalog to page 918 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
21 Pages
19 Pages
19 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages