Group: PULS
Catalog excerpts
CPS20.361 36V, 13.3A, SINGLE PHASE INPUT POWER SUPPLY AC 100-240V Wide-range Input Width only 65mm Efficiency up to 94.3% Excellent Partial Load Efficiency 20% Output Power Reserves Safe HiccupPLUS Overload Mode Easy Fuse Breaking due to High Overload Current (typ. 50A for 15ms) Active Power Factor Correction (PFC) Minimal Inrush Current Surge Full Power Between -25°C and +60°C DC-OK Relay Contact Current Sharing Feature for Parallel Use 3 Year Warranty GENERAL DESCRIPTION SHORT-FORM DATA The Dimension C-Series are cost optimized power supplies without compromising quality, reliability and performance. The C-Series is part of the DIMENSION power supply family. The most outstanding features of CPS20.361 are the high efficiency, electronic inrush current limitation, active PFC, wide operational temperature range. The small size is achieved by a synchronous rectification and further technological design details. Output voltage Adjustment range Output current The C-Series includes all the essential basic functions. The devices have a power reserve of 20% included, which may even be used continuously at temperatures up to +45°C. Additionally, the CPS20.361 can deliver about 4 times the nominal output current for 15ms which helps to trip fuses on faulty output branches. High immunity to transients and power surges as well as low electromagnetic emission, a DC-OK relay contact and a large international approval package for a variety of applications makes this unit suitable for nearly every situation. ORDER NUMBERS Power Supply Wall mount bracket Side mount bracket Redundancy module Marine, pending May. 2013 / Rev. 1.2 DS-CPS20.361-EN All parameters are specified at 36V, 13.3A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0
Open the catalog to page 1CPS20.361 36V, 13.3A, SINGLE PHASE INPUT The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents a nominal voltage with...
Open the catalog to page 2CPS20.361 36V, 13.3A, SINGLE PHASE INPUT 1. INTENDED USE This device is designed for installation in an enclosure and is intended for the general professional use such as in industrial control, office, communication, and instrumentation equipment. Do not use this power supply in equipment, where malfunction may cause severe personal injury or threaten human life. This device is designed for use in hazardous (pending), non-hazardous, ordinary or unclassified locations. 2. INSTALLATION REQUIREMENTS This device may only be installed and put into operation by qualified personnel. This device...
Open the catalog to page 3□innefUSIOfU C-Series 36V, 13.3A, SINGLE PHASE INPUT suitable for TN-, TT- and IT mains networks continuous operation short term or with output derating (1 %/V) or with reduced ambient temperature, see Fig. 15-1, Allowed voltage L or N to earth max. 300Vac Input frequency Turn-on voltage Shut-down voltage steady-state value at 3.3A load, see Fig. 3-1 steady-state value at 6.7A load, see Fig. 3-1 steady-state value at 13.3A load, see Fig. 3-1 Rise time typ. 90ms 90ms 90ms at 36V, 13.3A const, current load, OmF load capacitance, load, 15mF load capacitance, *) The power factor is the ratio of...
Open the catalog to page 4□innefUSIOfU C-Series 36V, 13.3A, SINGLE PHASE INPUT Fig. 3-3 Input current vs. output current Fig. 3-4 Power factor vs. output current Do not operate this power supply with DC-input voltage. I 5. INPUT INRUSH CURRENT An active inrush limitation circuit limits the input inrush current after turn-on of the input voltage and after short input voltage interruptions. The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Inrush current*' Inrush energy*: typ. 11 Apeak 9APeak 7Apeak temperature independent Fig. 5-1 Typical input inrush...
Open the catalog to page 5CPS20.361 36V, 13.3A, SINGLE PHASE INPUT 6. OUTPUT Output voltage Adjustment range Ripple and noise voltage Output current Output power Factory settings Line regulation Load regulation Overload behaviour Short-circuit current Output capacitance *) guaranteed at clockwise end position of potentiometer ±0.2%, at full load, cold unit, in “single use” mode ±0.2%, at full load, cold unit, in “parallel use” mode at no load, cold unit, in “parallel use” mode 85-300Vac in “single use” mode: static value, 0A 13.3A; see Fig. 6-1 in “parallel use” mode: static value, 0A 13.3A, see Fig. 6-2 20Hz to...
Open the catalog to page 6□innefUSIOfU C-Series 36V, 13.3A, SINGLE PHASE INPUT Fig. 6-1 Output voltage vs. output current, Output Voltage (Single Use, typ.) Fig. 6-2 Output voltage in "parallel use" Output Voltage (Parallel Use, typ.) Fig. 6-3 Short-circuit on output. Hiccup1*"5 mode, typ. Short -circuit Fig. 6-4 Dynamic overcurrent capability, typ. Output Voltage (dynamic behavior, < 15ms) Output Current All parameters are specified at 36V, 13.3A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Open the catalog to page 7□innefUSIOfU C-Series 36V, 13.3A, SINGLE PHASE INPUT Hold-up Time Fig. 7-1 Hold-up time vs. input voltage Fig. 7-2 Shut-down behavior, definitions Hold-up Time Input Voltage Zero Transition Hold-up Time j 8. DC-OK RELAY CONTACT This feature monitors the output voltage, which is produced by the power supply itself. It is independent of a back-fed voltage from a unit connected in parallel to the power supply output. Contact closes As soon as the output voltage reaches 90% of the adjusted output voltage level. Contact opens As soon as the output voltage dips more than 10% below the adjusted...
Open the catalog to page 8All PULS GmbH catalogs and technical brochures
-
FPT500 series
35 Pages
-
FPS300 series
32 Pages
-
CD10.242
29 Pages
-
DECENTRALIZED POWER SUPPLIES
9 Pages
-
PIANO
5 Pages
-
PIANO PIC
2 Pages
-
selection guide 2018
31 Pages
-
PULS CP
7 Pages
-
Selection Guide 2015/2016
25 Pages
-
CP10.241
27 Pages
-
CP10.241-S1
27 Pages
-
PIC120.241D
22 Pages
-
CP10.121
26 Pages
-
SLR01
2 Pages
-
SLZ14
2 Pages
-
SLZ12
2 Pages
-
SLZ11
2 Pages
-
SLZ02
2 Pages
-
SLR10.100
2 Pages
-
SL40.301
2 Pages
-
SL40.300
2 Pages
-
SL30.300
2 Pages
-
SL20.303
2 Pages
-
SL20.310
2 Pages
-
SL20.301
2 Pages
-
SL20.300
2 Pages
-
SL10.309
2 Pages
-
SL10.305
4 Pages
-
SL10.300
2 Pages
-
SL5.300
2 Pages
-
SL30.100
2 Pages
-
SL20.115
2 Pages
-
SL20.113
2 Pages
-
SL20.112
2 Pages
-
SL20.111
2 Pages
-
SL20.110
2 Pages
-
SL20.101
2 Pages
-
SL20.100
2 Pages
-
SL10.106
2 Pages
-
SL10.105
2 Pages
-
SL10.10
2 Pages
-
SL10.104
2 Pages
-
SL10.101
2 Pages
-
SL10.100
2 Pages
-
SL5.105
2 Pages
-
SL5.102
2 Pages
-
SL5.100
2 Pages
-
SL4.100
2 Pages
-
SL2.103
2 Pages
-
SL2.100
2 Pages
-
ML100.200
2 Pages
-
ML90.200
2 Pages
-
ML100.105
2 Pages
-
ML100.102
2 Pages
-
ML100.100
2 Pages
-
ML95.100
2 Pages
-
ML70.100
2 Pages
-
ML60.121
23 Pages
-
ML50.111
2 Pages
-
ML50.109
20 Pages
-
ML50.105
2 Pages
-
ML50.102
2 Pages
-
ML50.101
2 Pages
-
ML50.100
20 Pages
-
ML30.241
23 Pages
-
ML30.106
2 Pages
-
ML30.102
2 Pages
-
ML30.101
2 Pages
-
ML30.100
2 Pages
-
ML15.241
23 Pages
-
ML15.121
23 Pages
-
ML15.051
22 Pages
-
YRM2.DIODE
19 Pages
-
YR80.241
17 Pages
-
YR40.241
17 Pages
-
YR2.DIODE
19 Pages
-
XT40.722
19 Pages
-
XT40.721
19 Pages
-
XT40.482
20 Pages
-
XT40.481
20 Pages
-
XT40.362
20 Pages
-
XT40.361
20 Pages
-
XT40.242
20 Pages
-
XT40.241
20 Pages
-
ZM15.SIDE
2 Pages
-
ZM14.SIDE
2 Pages
-
ZM13.SIDE
2 Pages
-
ZM12.SIDE
2 Pages
-
ZM11.SIDE
2 Pages
-
ZM2.WALL
3 Pages
-
ZM1.WALL
2 Pages
-
ZM1.UBC10
2 Pages
-
UZS24.100
3 Pages
-
UF20.481
13 Pages
-
UF20.241
11 Pages
-
UZO12.26
2 Pages
-
UZO12.07
9 Pages
-
UZK12.261
8 Pages
-
UZK12.071
9 Pages
-
UBC10.241-N1
23 Pages
-
UBC10.241
23 Pages
-
UB10.245
24 Pages
-
UB10.242
21 Pages
-
UB10.241
23 Pages
-
QT40.481
28 Pages
-
QT40.241
28 Pages
-
QT20.481
23 Pages
-
QT20.361
23 Pages
-
QT20.241-C1
23 Pages
-
QT20.241
23 Pages
-
QTD20.241
22 Pages
-
QS10.481-D1
27 Pages
-
QS10.241-D1
27 Pages
-
QS40.484
28 Pages
-
QS40.244
28 Pages
-
QS20.481
25 Pages
-
QS20.361
25 Pages
-
QS20.244
25 Pages
-
QS20.241-C1
26 Pages
-
QS20.241-A1
26 Pages
-
QS20.241
26 Pages
-
QS10.481
27 Pages
-
QS10.DNET
22 Pages
-
QS10.301
26 Pages
-
QS10.241-C1
27 Pages
-
QS10.241-A1
27 Pages
-
QS10.241
28 Pages
-
QS10.121
26 Pages
-
QS5.DNET
21 Pages
-
QS5.241-A1
26 Pages
-
QS5.241
26 Pages
-
QS3.241
25 Pages
-
PISA11.CLASS2
19 Pages
-
PISA11.206212
23 Pages
-
PISA11.203206
23 Pages
-
PISA11.410
23 Pages
-
PISA11.406
23 Pages
-
PISA11.404
23 Pages
-
PISA11.403
23 Pages
-
PISA11.402
23 Pages
-
PISA11.401
23 Pages
-
PIC240.241D
21 Pages
-
PIC120.241C
21 Pages
-
PAS395
14 Pages
-
CT10.481
22 Pages
-
CT10.241
22 Pages
-
CT5.241
21 Pages
-
CT5.121
21 Pages
-
CS10.481
20 Pages
-
CS10.244
21 Pages
-
CS10.243
19 Pages
-
CS10.242
19 Pages
-
CS10.241-S1
20 Pages
-
CS10.241
20 Pages
-
CS5.244
20 Pages
-
CS5.243
19 Pages
-
CS5.241-S1
20 Pages
-
CS5.241-C1
20 Pages
-
CS5.241
20 Pages
-
CS3.241
21 Pages
-
CPS20.241-C1
26 Pages
-
CPS10.241
26 Pages
-
CP10.242
27 Pages
-
CD5.243
22 Pages
-
CD5.242
22 Pages
-
CD5.241-S1
23 Pages
-
CD5.241-L1
21 Pages
-
CD5.241
22 Pages
-
CD5.121
22 Pages
-
PIC120.242C
21 Pages
-
PIC240.241C
20 Pages
-
QS40.361
27 Pages
-
QS40.481
28 Pages
-
QT40.361
27 Pages
-
UB20.241
31 Pages
-
UZK24.071
9 Pages
-
UZK24.121
9 Pages
-
UZO24.071
9 Pages
-
UZO24.121
9 Pages
-
UC10.241
27 Pages
-
UC10.242
27 Pages
-
YR40.242
17 Pages
-
YR40.245
18 Pages
-
YR40.482
17 Pages
-
YR80.242
17 Pages
-
SLA3.100
4 Pages
-
SLA4.100
4 Pages
-
SLA8.100
4 Pages
-
SLA8.300
4 Pages
-
SLAD4.100
4 Pages
-
SLD2.100
2 Pages
-
SLR02
2 Pages
-
SLR2.100
2 Pages
-
SLR5.100
2 Pages
-
SLR10.108
2 Pages
-
SLV20.200
4 Pages
-
SLZ10-14
2 Pages
-
ML60.122
23 Pages
-
ML60.241
23 Pages
-
ML60.242
23 Pages
-
ML120.241
22 Pages
-
ML120.244
21 Pages
-
ML120.CLASS2
19 Pages
-
MLY02.100
16 Pages
-
MLY10.241
16 Pages
-
ZM3.WALL
1 Pages
-
CPS20.481-D1
25 Pages
-
CPS20.241-D1
25 Pages
-
Selection Guide 2013
19 Pages
-
QS40.241, QS40.241-A1
28 Pages
-
CPS20.241
25 Pages
-
CPS20.481
25 Pages
-
CPS20.121
25 Pages
Archived catalogs
-
PIC120.241D
21 Pages
-
Products 2009-2010
28 Pages
-
Products 2007
34 Pages