video corpo

CP10.242
27Pages

{{requestButtons}}

Catalog excerpts

CP10.242 - 1

POWER SUPPLY AC 100-240V Wide-range Input Width only 39mm Optional with Spring-clamp Terminals (CP10.241-S1) Optional with Extended DC Input Range (CP10.242) Efficiency up to 95.2%, Excellent Partial Load Efficiency 20% Output Power Reserves Safe HiccupPLUS Overload Mode Easy Fuse Breaking due to High Overload Peak Current Active Power Factor Correction (PFC) Minimal Inrush Current Surge Full Power Between -25°C and +60°C DC-OK Relay Contact Meets ITE, ATEX, Class I Div2 and SEMI F47 Requirements 3 Year Warranty GENERAL DESCRIPTION SHORT-FORM DATA The DIMENSION CP-Series units are high-end power supplies in a medium price range without compromising quality, reliability and performance. The CP-Series is part of the DIMENSION power supply family. The most outstanding features of CP10.241 are the high efficiency, advanced inrush current limitation, active PFC and the wide operational temperature range. High immunity to transients and power surges as well as low electromagnetic emission, a DC-OK relay contact and a large international approval package for a variety of applications makes this unit suitable for nearly every situation. Output voltage DC 24V Adjustment range 24 – 28V Output current 10A 12A 8.6A 10.3A Output power 240W / 288W Output ripple < 50mVpp AC Input voltage AC 100-240V Mains frequency 50-60Hz AC Input current 2.15 / 1.13A Power factor 0.99 / 0.97 AC Inrush current 6 / 9A pk DC Input DC 110-150V ±20% DC 110-300V ±20% Efficiency 93.6 / 95.2% Losses 16.4 / 12.1W Temp. range -25°C to +70°C Derating 6W/°C Hold-up time 37 / 37ms Dimensions 39x124x117mm Weight 600g / 1.3lb ORDER NUMBERS The CP-Series includes all the essential basic functions. The devices have a power reserve of 20% included, which may even be used continuously at temperatures up to +45°C. Additionally, the CP10 can deliver three times the nominal output current for at least 12ms which helps to trip fuses on faulty output branches. The CP10.241-S1 is equipped with quick-connect springclamp terminals for a fast and reliable electrical connection. Spring-clamp terminals are the preferred terminals when applications are exposed to mechanical vibration. Power Supply 24-28V Standard unit With Extended DC Input (DC 110-300V) CP10.241-S1 24-28V with spring-clamp terminals Wall mount bracket Side mount bracket Redundancy module IECEx Class I Div 2 planned Apr. 2015 / Rev. 1.1 DS-CP10.241-EN All parameters are specified at 24V, 10A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Marine, planned

Open the catalog to page 1
CP10.242 - 2

The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. PE is the abbreviation for Protective Earth and has the same meaning as the symbol Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. To be defined, value or description will follow later. A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included....

Open the catalog to page 2
CP10.242 - 3

1. INTENDED USE This device is designed for installation in an enclosure and is intended for the general professional use such as in industrial control, office, communication, and instrumentation equipment. Do not use this power supply in equipment, where malfunction may cause severe personal injury or threaten human life. 2. INSTALLATION REQUIREMENTS This device may only be installed and put into operation by qualified personnel. This device does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect. If damage or malfunction should occur during...

Open the catalog to page 3
CP10.242 - 4

3. AC-INPUT AC input AC input range Shut-down voltage External input protection nom. AC 100-240V suitable for TN-, TT- and IT mains networks min. 85-264Vac continuous operation min. 264-300Vac < 500ms max. 300Vac continuous, IEC 62103 nom. 50–60Hz ±6% typ. 80Vac steady-state value, see Fig. 3-1 typ. 55Vac dynamic value (250ms) typ. 74Vac steady-state value, see Fig. 3-1 See recommendations in chapter 22.3. Input current Power factor*) Crest factor**) Start-up delay Rise time Allowed voltage L or N to earth Input frequency Turn-on voltage Turn-on overshoot External input protection at 24V,...

Open the catalog to page 4
CP10.242 - 5

Fig. 3-3 Input current vs. output current at 24V output voltage Fig. 3-4 Power factor vs. output current at 24V output voltage Output Current 4. DC-INPUT DC input DC input range DC input current Allowed Voltage L/N to Earth Turn-on voltage Shut-down voltage CP10.241, CP10.241-S1 CP10.242 CP10.241, CP10.241-S1, continuous operation CP10.242 at 110Vdc, at 24V, 10A at 300Vdc, at 24V, 10A, CP10.242 continuous, IEC 62103 steady state value steady state value Instructions for DC use: a) Use a battery or a similar DC source. A supply from the intermediate DC-bus of a frequency converter is not...

Open the catalog to page 5
CP10.242 - 6

□innerusioru cp-senes 24V, IOA, SINGLE PHASE INPUT I 5. INPUT INRUSH CURRENT_ An active inrush limitation circuit (NTCs, which are bypassed by a relay contact) limits the input inrush current after turn-on of the input voltage. The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Inrush current max. 11Apeak 7Apeak 11Apeak at 40°C, cold start Inrush energy max. 0.1A2s 0.1 A2s 0.4A2s at 40°C, cold start Fig. 5-1 Typical turn-on behaviour at nominal load, 120Vac input and 25°C ambient Fig. 5-2 Typical turn-on behaviour at nominal load,...

Open the catalog to page 6
CP10.242 - 7

6. OUTPUT Output voltage Adjustment range Factory settings Line regulation Load regulation Ripple and noise voltage Output current Output power Overload behaviour Short-circuit current Output capacitance guaranteed at clockwise end position of potentiometer ±0.2%, at full load and cold unit 85-300Vac static value, 0A 10A; see Fig. 6-1 20Hz to 20MHz, 50Ohm at 24V, ambient temperature <60°C, see Fig. 6-1 at 24V, ambient temperature <45°C, see Fig. 15-1 at 24V and 70°C ambient temperature, see Fig. 15-1 at 28V, ambient temperature <60°C, see Fig. 6-1 at 28V, ambient temperature <45°C, see Fig....

Open the catalog to page 7

All PULS GmbH catalogs and technical brochures

  1. FPT500 series

    35 Pages

  2. FPS300 series

    32 Pages

  3. CD10.242

    29 Pages

  4. PIANO

    5 Pages

  5. PIANO PIC

    2 Pages

  6. PULS CP

    7 Pages

  7. CP10.241

    27 Pages

  8. CP10.241-S1

    27 Pages

  9. PIC120.241D

    22 Pages

  10. CP10.121

    26 Pages

  11. SLR01

    2 Pages

  12. SLZ14

    2 Pages

  13. SLZ12

    2 Pages

  14. SLZ11

    2 Pages

  15. SLZ02

    2 Pages

  16. SLR10.100

    2 Pages

  17. SL40.301

    2 Pages

  18. SL40.300

    2 Pages

  19. SL30.300

    2 Pages

  20. SL20.303

    2 Pages

  21. SL20.310

    2 Pages

  22. SL20.301

    2 Pages

  23. SL20.300

    2 Pages

  24. SL10.309

    2 Pages

  25. SL10.305

    4 Pages

  26. SL10.300

    2 Pages

  27. SL5.300

    2 Pages

  28. SL30.100

    2 Pages

  29. SL20.115

    2 Pages

  30. SL20.113

    2 Pages

  31. SL20.112

    2 Pages

  32. SL20.111

    2 Pages

  33. SL20.110

    2 Pages

  34. SL20.101

    2 Pages

  35. SL20.100

    2 Pages

  36. SL10.106

    2 Pages

  37. SL10.105

    2 Pages

  38. SL10.10

    2 Pages

  39. SL10.104

    2 Pages

  40. SL10.101

    2 Pages

  41. SL10.100

    2 Pages

  42. SL5.105

    2 Pages

  43. SL5.102

    2 Pages

  44. SL5.100

    2 Pages

  45. SL4.100

    2 Pages

  46. SL2.103

    2 Pages

  47. SL2.100

    2 Pages

  48. ML100.200

    2 Pages

  49. ML90.200

    2 Pages

  50. ML100.105

    2 Pages

  51. ML100.102

    2 Pages

  52. ML100.100

    2 Pages

  53. ML95.100

    2 Pages

  54. ML70.100

    2 Pages

  55. ML60.121

    23 Pages

  56. ML50.111

    2 Pages

  57. ML50.109

    20 Pages

  58. ML50.105

    2 Pages

  59. ML50.102

    2 Pages

  60. ML50.101

    2 Pages

  61. ML50.100

    20 Pages

  62. ML30.241

    23 Pages

  63. ML30.106

    2 Pages

  64. ML30.102

    2 Pages

  65. ML30.101

    2 Pages

  66. ML30.100

    2 Pages

  67. ML15.241

    23 Pages

  68. ML15.121

    23 Pages

  69. ML15.051

    22 Pages

  70. YRM2.DIODE

    19 Pages

  71. YR80.241

    17 Pages

  72. YR40.241

    17 Pages

  73. YR2.DIODE

    19 Pages

  74. XT40.722

    19 Pages

  75. XT40.721

    19 Pages

  76. XT40.482

    20 Pages

  77. XT40.481

    20 Pages

  78. XT40.362

    20 Pages

  79. XT40.361

    20 Pages

  80. XT40.242

    20 Pages

  81. XT40.241

    20 Pages

  82. ZM15.SIDE

    2 Pages

  83. ZM14.SIDE

    2 Pages

  84. ZM13.SIDE

    2 Pages

  85. ZM12.SIDE

    2 Pages

  86. ZM11.SIDE

    2 Pages

  87. ZM2.WALL

    3 Pages

  88. ZM1.WALL

    2 Pages

  89. ZM1.UBC10

    2 Pages

  90. UZS24.100

    3 Pages

  91. UF20.481

    13 Pages

  92. UF20.241

    11 Pages

  93. UZO12.26

    2 Pages

  94. UZO12.07

    9 Pages

  95. UZK12.261

    8 Pages

  96. UZK12.071

    9 Pages

  97. UBC10.241-N1

    23 Pages

  98. UBC10.241

    23 Pages

  99. UB10.245

    24 Pages

  100. UB10.242

    21 Pages

  101. UB10.241

    23 Pages

  102. QT40.481

    28 Pages

  103. QT40.241

    28 Pages

  104. QT20.481

    23 Pages

  105. QT20.361

    23 Pages

  106. QT20.241-C1

    23 Pages

  107. QT20.241

    23 Pages

  108. QTD20.241

    22 Pages

  109. QS10.481-D1

    27 Pages

  110. QS10.241-D1

    27 Pages

  111. QS40.484

    28 Pages

  112. QS40.244

    28 Pages

  113. QS20.481

    25 Pages

  114. QS20.361

    25 Pages

  115. QS20.244

    25 Pages

  116. QS20.241-C1

    26 Pages

  117. QS20.241-A1

    26 Pages

  118. QS20.241

    26 Pages

  119. QS10.481

    27 Pages

  120. QS10.DNET

    22 Pages

  121. QS10.301

    26 Pages

  122. QS10.241-C1

    27 Pages

  123. QS10.241-A1

    27 Pages

  124. QS10.241

    28 Pages

  125. QS10.121

    26 Pages

  126. QS5.DNET

    21 Pages

  127. QS5.241-A1

    26 Pages

  128. QS5.241

    26 Pages

  129. QS3.241

    25 Pages

  130. PISA11.CLASS2

    19 Pages

  131. PISA11.206212

    23 Pages

  132. PISA11.203206

    23 Pages

  133. PISA11.410

    23 Pages

  134. PISA11.406

    23 Pages

  135. PISA11.404

    23 Pages

  136. PISA11.403

    23 Pages

  137. PISA11.402

    23 Pages

  138. PISA11.401

    23 Pages

  139. PIC240.241D

    21 Pages

  140. PIC120.241C

    21 Pages

  141. PAS395

    14 Pages

  142. CT10.481

    22 Pages

  143. CT10.241

    22 Pages

  144. CT5.241

    21 Pages

  145. CT5.121

    21 Pages

  146. CS10.481

    20 Pages

  147. CS10.244

    21 Pages

  148. CS10.243

    19 Pages

  149. CS10.242

    19 Pages

  150. CS10.241-S1

    20 Pages

  151. CS10.241

    20 Pages

  152. CS5.244

    20 Pages

  153. CS5.243

    19 Pages

  154. CS5.241-S1

    20 Pages

  155. CS5.241-C1

    20 Pages

  156. CS5.241

    20 Pages

  157. CS3.241

    21 Pages

  158. CPS20.241-C1

    26 Pages

  159. CPS10.241

    26 Pages

  160. CD5.243

    22 Pages

  161. CD5.242

    22 Pages

  162. CD5.241-S1

    23 Pages

  163. CD5.241-L1

    21 Pages

  164. CD5.241

    22 Pages

  165. CD5.121

    22 Pages

  166. PIC120.242C

    21 Pages

  167. PIC240.241C

    20 Pages

  168. QS40.361

    27 Pages

  169. QS40.481

    28 Pages

  170. QT40.361

    27 Pages

  171. UB20.241

    31 Pages

  172. UZK24.071

    9 Pages

  173. UZK24.121

    9 Pages

  174. UZO24.071

    9 Pages

  175. UZO24.121

    9 Pages

  176. UC10.241

    27 Pages

  177. UC10.242

    27 Pages

  178. YR40.242

    17 Pages

  179. YR40.245

    18 Pages

  180. YR40.482

    17 Pages

  181. YR80.242

    17 Pages

  182. SLA3.100

    4 Pages

  183. SLA4.100

    4 Pages

  184. SLA8.100

    4 Pages

  185. SLA8.300

    4 Pages

  186. SLAD4.100

    4 Pages

  187. SLD2.100

    2 Pages

  188. SLR02

    2 Pages

  189. SLR2.100

    2 Pages

  190. SLR5.100

    2 Pages

  191. SLR10.108

    2 Pages

  192. SLV20.200

    4 Pages

  193. SLZ10-14

    2 Pages

  194. ML60.122

    23 Pages

  195. ML60.241

    23 Pages

  196. ML60.242

    23 Pages

  197. ML120.241

    22 Pages

  198. ML120.244

    21 Pages

  199. ML120.CLASS2

    19 Pages

  200. MLY02.100

    16 Pages

  201. MLY10.241

    16 Pages

  202. ZM3.WALL

    1 Pages

  203. CPS20.481-D1

    25 Pages

  204. CPS20.241-D1

    25 Pages

  205. CPS20.241

    25 Pages

  206. CPS20.361

    25 Pages

  207. CPS20.481

    25 Pages

  208. CPS20.121

    25 Pages

Archived catalogs

  1. PIC120.241D

    21 Pages

  2. Products 2007

    34 Pages