□innerusionj cp-series Power Supply ■ Excellent partial load efficiency ■ 20% output power reserves (PowerBoost) ■ Safe Hiccup^ overload mode ■ Easy fuse breaking due to high overload peak current ■ Active power factor correction (PFC) ■ Minimal inrush current surge ■ Full power between -25°C and +60°C ■ DC-oK relay contact The DIMENSION CP-Series units are high-end power supplies in a medium price range without compromising quality, reliability and performance. The CP-Series is part of the DIMENSION power supply family. The most outstanding features of CP10 series are the high efficiency, advanced inrush current limitation, active PFC and the wide operational temperature range. The CP-Series includes all the essential basic functions. The devices also offer PowerBoost: Power reserves of 20%, which may even be used continuously at temperatures up to +45°C. Additionally, the CP10 can deliver three times the nominal output current for at least 12ms which helps to trip fuses on faulty output branches. High immunity to transients and power surges as well as low electromagnetic emission, a DC-OK relay contact and a large international approval package for a variety of applications makes this unit suitable for nearly every situation. CP10.241-C1 Conformal coating CP10.241-S1 Spring-clamp terminals CP10.241-S2 Push-in terminals CP10.242 Extended DC-Input range Accessory ZM10.WALL Wall/panel mount bracket ZM12.SIDE Side mount bracket Output voltage DC 24V nominal Adjustment range 24 - 28V factory setting 24.1V Output current 10.0-8.6A up to +60°C ambient Derate linearly between +60°C and +70°C PowerBoost 12.0A up to +45°C ambient Linear decrease to nominal power _between +45°C and +60°C._ Size (w x h x d) 39x124x117mm without DIN rail For details and the complete approval list, see chapter 20. All values are typical at 24V, 10A, 230Vac, 50Hz, +25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Open the catalog to page 1□in/iemsiom CP-Series 23.1. ZM10.WALL - Wall/Panel Mount Bracket 24 23.4. YR20.246 - Redundancy Module with The information given in this document is correct to the best of our knowledge and experience at the time of publication. If not expressly agreed otherwise, this information does not represent a warranty in the legal sense of the word. As the state of our knowledge and experience is constantly changing, the information in this data sheet is subject to revision. We therefore kindly ask you to always use the latest issue of this document (available under www.pulspower.com). No part of this...
Open the catalog to page 224V, 10A, 240W, SINGLE PHASE INPUT 1. INTENDED USE This device is designed for installation in an enclosure and is intended for commercial use, such as in industrial control, process control, monitoring and measurement equipment or the like. Do not use this device in equipment, where malfunctioning may cause severe personal injury or threaten human life without additional appropriate safety devices, that are suited for the application. If this device is used in a manner outside of its specification, the protection provided by the device may be impaired. 2. INSTALLATION INSTRUCTIONS WARNING -...
Open the catalog to page 324V, 10A, 240W, SINGLE PHASE INPUT The device is designed for altitudes up to 5000m. Above 2000m a reduction in output current and over voltage category is required. Keep the following minimum installation clearances: 40mm on top, 20mm on the bottom, 5mm left and right side. Increase the 5mm to 15mm in case the adjacent device is a heat source. When the device is permanently loaded with less than 50%, the 5mm can be reduced to zero. The device is designed, tested and approved for branch circuits up to 32A (IEC) and 30A (UL) without additional protection device. If an external fuse is utilized,...
Open the catalog to page 4□in/iemsiom CP-Series AC input AC input range Nom. AC 100-240V Suitable for TN-, TT- and IT mains networks Allowed voltage L or N to earth Max. 300Vac Continuous, according to I EC 62477-1 Turn-on voltage Typ. 80Vac Steady-state value, see Fig. 3-1 Shut-down voltage Typ. 70Vac Steady-state value, see Fig. 3-1 Typ. 55Vac Dynamic value for maximal 250ms External input protection See recommendations in chapter 24.3. Rise time Typ. 30ms 30ms 30ms At 24V, 10A const. current load, Typ. 75ms 75ms 75ms at 24V, 10A const. current load, External input protection See recommendations in chapter 24.3. Input...
Open the catalog to page 5Fig. 3-3 Input current vs. output current at 24V output voltage Fig. 3-4 Power factor vs. output current at 24V output voltage Output Current Output Current DC input current Allowed Voltage L/N to Earth Turn-on voltage Shut-down voltage ±20% For CP10.241, CP10.241-C1, CP10.241-S1, CP10.241-S2 ±20% For CP10.242 For CP10.241, CP10.241-C1, CP10.241-S1, CP10.241-S2 For CP10.242 At 110Vdc, at 24V, 10A At 300Vdc, at 24V, 10A Continuous, according to IEC 62477-1 Steady state value Steady state value Dynamic value for maximal 250ms Instructions for DC use: a) Use a battery or a similar DC source. A supply...
Open the catalog to page 65. INPUT INRUSH CURRENT An active inrush limitation circuit (NTCs, which are bypassed by a relay contact) limits the input inrush current after turn-on of the input voltage. The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Inrush current Inrush energy Fig. 5-1 Typical turn-on behaviour at nominal load, 120Vac input and 25°C ambient At 40°C, cold start At 25°C, cold start At 40°C, cold start At 40°C, cold start Fig. 5-2 Typical turn-on behaviour at nominal load, 230Vac input and 25°C ambient Aug. 2025 / Rev. 1.9 DS-CP10.241-EN All values...
Open the catalog to page 7□in/iemsiom CP-Series CP10.241, CP10.241-C1, CP10.241-S1,CP10.241-S2, CP10.24224V, 10A, 240W, Single Phase Input| 6. Output Output voltage Adjustment range Factory settings Line regulation Load regulation Ripple and noise voltage Output current Fuse breaking current Max. 30.0V This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not a guaranteed value which can be achieved. Typ. 24.1V ±0.2%, at full load and cold unit Max. 50mV Between 0 and 12A, static value, see Fig. 6-1 Derate linearly between +60°C and +70°C, see chapter...
Open the catalog to page 818 Pages
18 Pages
28 Pages
29 Pages
21 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
20 Pages
23 Pages
2 Pages
2 Pages
2 Pages
2 Pages
23 Pages
23 Pages
22 Pages
19 Pages
17 Pages
17 Pages
19 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
13 Pages
11 Pages
2 Pages
9 Pages
8 Pages
9 Pages
23 Pages
23 Pages
24 Pages
21 Pages
23 Pages
28 Pages
28 Pages
23 Pages
23 Pages
23 Pages
23 Pages
22 Pages
27 Pages
27 Pages
28 Pages
28 Pages
25 Pages
25 Pages
25 Pages
26 Pages
26 Pages
26 Pages
27 Pages
22 Pages
26 Pages
21 Pages
26 Pages
26 Pages
25 Pages
19 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
21 Pages
21 Pages
14 Pages
22 Pages
22 Pages
21 Pages
21 Pages
20 Pages
21 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
19 Pages
20 Pages
20 Pages
20 Pages
21 Pages
26 Pages
26 Pages
27 Pages
22 Pages
22 Pages
23 Pages
21 Pages
22 Pages
22 Pages
21 Pages
20 Pages
27 Pages
28 Pages
31 Pages
9 Pages
9 Pages
9 Pages
9 Pages
27 Pages
27 Pages
17 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
35 Pages
26 Pages
28 Pages
27 Pages
27 Pages
25 Pages
31 Pages
9 Pages
2 Pages
7 Pages
17 Pages
17 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
23 Pages
23 Pages
23 Pages
22 Pages
21 Pages
19 Pages
26 Pages
5 Pages
1 Page
25 Pages
25 Pages
19 Pages
28 Pages
25 Pages
25 Pages
25 Pages
25 Pages
22 Pages
21 Pages
28 Pages
34 Pages