LEAK-05A Evacuated Receptacle Draw Volume Tester
1 /2Pages

LEAK-05A Evacuated Receptacle Draw Volume Tester

LEAK-05A Evacuated Receptacle Draw Volume Tester
1 /2Pages

Catalog excerpts

LEAK-05A Evacuated Receptacle Draw Volume Tester-1

LEAK-05A Evacuated Receptacle Draw Volume Tester is used to detected the draw volume of Single-use containers for human venous blood specimen collection. The equipment can measure the compliance of vacuum blood collection tube draw volume with standards at different altitudes. Product Features > Negative pressure method, the precise pressure test system, the test accuracy is greatly improve > Embedded micro-computer chips, simplified and efficient user interface provide users with comfortable and smooth operating experience > Imported high-speed and high-precision chips guarantee the testing accuracy and efficiency > Automatic constant pressure air supplement to ensure that the test can be carried out under preset vacuum conditions > Automatic blow back and unloading function, making the end of the test process simple and smooth > Safety design such as over-voltage safety protection and power-down memory ensure the stability of the system during the test > Equipped with standard RS232 interface, which is convenient to PC connection and data transmission > Low energy consumption makes the instrument environment-friendly Originality design > 7” HD LCD, displaying test data in real time > Vacuum degree and time can be preset, input the value can enter the test mode > With a powerful data storage function, which can store up to 50,000 test records > Equipped with Micro printer, the test data can be printed > Standard, modularized and systematic designs can meet personalized requirements of the users > Equipped with SMC vacuum generator, test data stable and reliable

 Open the catalog to page 1
LEAK-05A Evacuated Receptacle Draw Volume Tester-2

The test blood collection tube is inserted into the puncture site of the test system to maintain the pressure inside the vacuum chamber. Depending on the altitude of the area where the blood tubes are used, the pressure inside the blood collection tubes varies. After 1 min of resting, the volume of the blood tube was determined by measuring the difference in the weights of the blood tubes before and after sampling. ISO 6710:2017 MOD, YY0314-2021 Single-use containers for human venous blood specimen collection. Standard Configuration: Instrument, Vacuum chamber, Micro printer, Test frame

 Open the catalog to page 2