DTN-ZJ Catheter Cuff Inflating Diameter Tester
1 /3Pages

DTN-ZJ Catheter Cuff Inflating Diameter Tester

DTN-ZJ Catheter Cuff Inflating Diameter Tester
1 /3Pages

Catalog excerpts

DTN-ZJ Catheter Cuff Inflating Diameter Tester-1

PubtesterDTN-ZJ Catheter Cuff Inflating Diameter Tester DTN-ZJ Catheter Cuff Inflating Diameter Tester adopts the positive pressure test principle and is suitable for the measurement of the inflated diameter of the endotracheal tube cuff, the tube collapse test method, and the quantitative measurement of the cuff protrusion test method. Technical FeaturesProfessional technology Supports three test items: cuff inflated diameter, cannula collapse test method, cuff protrusion test method > Equipped with a pressure test tank, which can be used for both gas and liquid, and realize multiple test functions > With a dedicated test interface, suitable for various Luer, pagoda, cone and other joints > Equipped with a well-known brand pressure and flow adjustment knob, easy to operate > Overpressure safety protection, power-off memory and other safety designs ensure the stability of the system during the test > Equipped with standard RS232 interface, which is convenient to PC connection and data transmission Originality Design > 7-inch HD color LCD screen, real-time display of test data and curves > Pressure and time can be preset, input the value directly to enter the test mode > With a powerful data storage function, storing up to 100,000 test records > The result is determined automatically, the test data can be printed > Support historical data for quick viewing and printing

 Open the catalog to page 1
DTN-ZJ Catheter Cuff Inflating Diameter Tester-2

Pubtester Instruments Co., Ltd. ^t^Pubtester > With shutdown function for over-range pressure, which protects the sensor > Equipped with a four-level user security password policy to ensure the security of test data > The computer software fully complies with the requirements of GMP "Computerized System” and has functions such as user management, authority management, and data audit tracking.

 Open the catalog to page 2
DTN-ZJ Catheter Cuff Inflating Diameter Tester-3

Configuration Standard configuration: Instrument, liquid storage tank, micro printer, customized connector Note: 1.The gas supply port of the instrument is Φ8 mm PU Tubing; 2. Customers will need to prepare for gas supply.

 Open the catalog to page 3