The document provides technical specifications for the Laboratory Zero Air Gas Generator models A2, A5, A10, and A30, manufactured by Proton OnSite.
Specifications
  • Technologies Employed: Catalyzer
  • Flow Rate: A2: 2 SLPM, A5: 5 SLPM, A10: 10 SLPM, A30: 30 SLPM
  • Output Pressure: 0 to 7 barg / 0 to 100 psig
  • Total Hydrocarbon Residual: Less than 0.05 ppm (as methane)
Input Air Requirements
  • Particulate: Less than 0.1 mg/m3 (≤ 0.01 µm)
  • Oil Vapors: ≤ 0.01 mg/m3
  • Moisture: ≤ 3°C (37°F) dew point in pressure 0 to 7.6 barg (0 to 110 psig)
Electrical and Environmental Specifications
  • Electrical Supply: 120 VAC ± 10%, 50/60 Hz or 230 VAC ± 10%, 50/60 Hz
  • Ambient Operating Temperature: 60°F to 100°F / 16°C to 38°C
  • Ambient Humidity: ≤ 80% RH, non-condensing
  • Max Altitude: 2000 m / 6560 ft above sea level
Physical Characteristics
  • Unit Dimensions (H x W x D): 15.5” x 12” x 8” / 39.4 cm x 30.5 cm x 20.3 cm
  • Unit Weight: A2: 24 lbs / 10.9 kg, A5/A10/A30: 27.5 lbs / 12.5 kg
Additional Features
  • Wall-mountable
Compliance
  • CE, IEC/UL/CSA 61010-1
Specifications are subject to change, and the document emphasizes that organic compounds in the ambient or input air can negatively affect performance.
See more

Catalog excerpts

Zero Air A2, A5, A10, A30-1

PRDTDN THE LEADER IN DN SITE°GAS GENERATION. Technical Specifications Zero Air A2, A5, A10, A30Laboratory Zero Air Gas Generator ■ . . . . - -. • • - - \V-** ProtonOnSite.com | 01.203.949.8697 | [email protected]

 Open the catalog to page 1
Zero Air A2, A5, A10, A30-2

Technologies Employed Flow Rate1 Output Pressure Total Hydrocarbon Residual (as methane) Input Air Requirements < 0.05 ppm Particulate < 0.1 mg/m3 (≤ 0.01 µm) Oil vapors ≤ 0.01 mg/m3 Moisture ≤ 3°C (37°F) dew point in pressure 0 to 7.6 barg (0 to 110 psig) Electrical Supply2 Ambient Operating Temperature Ambient Humidity Unit Dimensions (H x W x D) Unit Weight ADDITIONAL FEATURES Wall-mountable COMPLIANCE CE, IEC/UL/CSA 61010-1 Specifications are subject to change. Measured at standard conditions: 21°C, 1 Atmosphere Electrical supply voltage is factory configured. * Organic compounds in the ambient...

 Open the catalog to page 2

All Proton Energy Systems catalogs and technical brochures

  1. H Series

    2  Pages

  2. S Series

    2  Pages

  3. Air A201

    2  Pages

  4. A5, A20

    2  Pages

  5. Air A3000P

    2  Pages

  6. Nitrogen N5P

    2  Pages

  7. Laboratory GC

    2  Pages

  8. G4800

    2  Pages

  9. Nigen MICRO

    2  Pages

  10. NigenGC

    2  Pages

  11. NiGen_LCMS

    2  Pages

  12. aircomp

    2  Pages

  13. HyGen

    2  Pages

  14. AirGen_TOC

    2  Pages

  15. ZeroAir

    2  Pages

  16. NiGen_UHP

    2  Pages

  17. iGen_Micro

    2  Pages

  18. HOGEN_C

    2  Pages

  19. StableFlow

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.