HOGEN C SERIES HYDROGEN GENERATION SYSTEM
1 /2Pages

HOGEN C SERIES HYDROGEN GENERATION SYSTEM

HOGEN C SERIES HYDROGEN GENERATION SYSTEM
1 /2Pages

Catalog excerpts

HOGEN C SERIES HYDROGEN GENERATION SYSTEM-1

Technical Specifications HOGEN® C Series Hydrogen Generation Systems Model DESCRIPTION On-site hydrogen generator in two integrated, automated, site-ready enclosures. Load Following operation automatically adjusts output to match demand. Automated Tank Filling operating with power-conservation mode during standby. ELECTROLYTE Proton Exchange Membrane (PEM) - caustic-free HYDROGEN PRODUCTION Net Production Rate: Nm3/hr @ 0° C, 1 bar SCF/hr @ 70° F, 1 atm SLPM @ 70° F, 1 atm kg per 24 hours Delivery Pressure - Nominal Power Consumed per Volume of Mass H2 Gas Produced** Purity (Concentration of Impurities)** 99.9998% (Water Vapor < 2 PPM, -72°C (-98°F) Dewpoint, N2 < 2 ppm O2 < 1 ppm, All others undetectable) Turndown Range 0 to 100% Net Product Delivery (Automatic) Field Upgradeable to a maximum of 30 Nm3 / hr (1140 SCF / hr) DI WATER REQUIREMENT Rate at Max. Consumption Rate Input Water Quality ASTM Type II Deionized Water required, < 1 micro Siemen / cm (>1 megOhm-cm) ASTM Type I Deionized Water recommended, <0.1 micro Siemen / cm (> 10 megOhm-cm) HEAT LOAD AND COOLANT REQUIREMENT Cooling Electrolyzer Liquid Cooled; Non-fouling; +5°C to 50°C (41°F to 122°F); 1.4 to 6.9 barg (30 to 100 PSIG) Flowrate: up to 133 L/min (35 gal/min) Pressure Drop: ~1.7 barg (~25 psig) Max. Heat Load (Cooling Requirement) 28.7 kW / 97,929 BTU/hr (8.2 tons refrig) 58.4 kW / 199,269 BTU/hr (16.6 tons refrig) 88.1 kW / 300,610 BTU/hr (25.1 tons refrig) Cooling Hydrogen Dryer & Power Supply Liquid Cooled; Non-fouling; +5°C to 40°C (41°F to 104°F); 1.4 to 6.9 barg (20 to 100 PSIG) Flowrate: up to 76 L/min (20 gal/min) Pressure Drop: ~1.0 barg (~15 psig) Max. Heat Load (Cooling Requirement) ** Subject to ambient and coolant temperatures. 4.8 kW / 16,379 BTU/hr (1.4 tons refrig) 8.4 kW / 28,662 BTU/hr (2.4 tons refrig) 12.1 kW / 41,287 BTU/hr (3.5 tons refrig) Consult Proton Applications Engineering Department for your specific application. www.protononsite.com | T 203.949.8697 | F 203.949.8016 | Proton OnSite 10 Technology Drive Wallingford, CT 06492 | [email protected]

 Open the catalog to page 1
HOGEN C SERIES HYDROGEN GENERATION SYSTEM-2

ELECTRICAL SPECIFICATIONS Recommended Breaker Rating Electrical Specification INTERFACE CONNECTIONS *Consult Installation Manual for details* H2 Product Port 3/8” Parker CPI™ compression tube fitting, SS Coolant Supply and Return Ports Electrolyzer Enclosure: 1-1/2” FNPT, brass (Cell Stack); 1/2” FNPT, brass (Hydrogen Dryer) Power Supply Enclosure 3/4” FNPT, brass (Power Supply Cooling) Drain Port Connect to inlet of disconnect box CONTROL SYSTEMS Standard Features - Fully automated - E-stop - Automatic fault detection and system depressurization Remote Alarm - Push button start/stop - On-board...

 Open the catalog to page 2

All Proton Energy Systems catalogs and technical brochures

  1. H Series

    2  Pages

  2. S Series

    2  Pages

  3. Air A201

    2  Pages

  4. A5, A20

    2  Pages

  5. Air A3000P

    2  Pages

  6. Nitrogen N5P

    2  Pages

  7. Laboratory GC

    2  Pages

  8. G4800

    2  Pages

  9. Nigen MICRO

    2  Pages

  10. NigenGC

    2  Pages

  11. NiGen_LCMS

    2  Pages

  12. aircomp

    2  Pages

  13. HyGen

    2  Pages

  14. AirGen_TOC

    2  Pages

  15. ZeroAir

    2  Pages

  16. NiGen_UHP

    2  Pages

  17. iGen_Micro

    2  Pages

  18. HOGEN_C

    2  Pages

  19. StableFlow

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.