Technical Specifications OverviewProduct Description:The H Series Hydrogen Generation Systems (Models H2, H4, H6) are on-site
hydrogen generators housed in integrated, automated, site-ready enclosures. They feature Load Following operation, which automatically adjusts output to match demand.
Electrolyte:Utilizes Proton Exchange Membrane (PEM) technology, which is caustic-free.
Hydrogen Production:- Net Production Rate: Ranges from 2 to 6 Nm3/hr, with corresponding outputs in SCF/hr, SLPM, and kg per 24 hours.
- Delivery Pressure: Nominal 15 barg (218 psig) with an option for 30 barg (435 psig).
- Purity: 99.9995% with minimal impurities.
- Turndown Range: 0 to 100% net product delivery, automatic.
- Upgradeability: Field upgradeable to a maximum of 6 Nm3/hr.
DI Water Requirement:- Consumption Rate: Varies with model, from 1.83 L/hr to 5.50 L/hr.
- Temperature and Pressure: 5°C to 50°C, 1.5 to 4 barg.
- Water Quality: ASTM Type II required, Type I recommended.
Heat Load and Coolant Requirement:- Cooling: Liquid-cooled, non-fouling, with specific temperature and flow rate requirements.
- Max Heat Load: Ranges from 8.1 kW to 23.7 kW depending on the model.
Electrical Specifications:- Breaker Rating: Ranges from 22 kVA to 55 kVA.
- Electrical Specification: 480 VAC, 3 phase, 60 Hz or 380-415 VAC, 3 phase, 50 Hz.
Interface Connections:Includes various ports for H2 product, venting, DI water, calibration gas, coolant supply and return, and drainage.
Control Systems:- Features: Fully automated with push button start/stop, E-stop, H2 leak detection, and automatic fault detection.
- Remote Alarm and Shutdown: Equipped with Form C relay and safety circuit trip.
Enclosure Characteristics:- Dimensions and Weight: Varies by model, with specific shipping dimensions and weights.
- IP Rating: IP66 for electronics, IP43 for fluids, upgradeable to IP56.
Environmental Considerations:- Standard Siting: Indoor, non-hazardous environments with specific temperature and humidity ranges.
- Storage/Transport Temperature: 5°C to 60°C.
- Altitude Range: Up to 2400 m above sea level.
Safety and Regulatory Conformity:- Maximum On-board H2 Inventory: Detailed for different pressures.
- Ventilation: Complies with NFPA 69 and EN 1127-1 standards.
- Noise Level: Less than 83 dB(A) at 1 meter.
- Conformity: cTUVus, CE certifications.