Catalog excerpts
DATASHEET EtherNet/IP™ to Modbus® Serial Four-Port Communication Gateway PLX31-EIP-MBS4 ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ PACs or devices and Modbus®-enabled PACs or devices. EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application. In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance. Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data, optimizing Ethernet bandwidth. Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time. Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery. Four serial ports allow for connectivity of up to 400 Modbus® devices, reducing the amount of gateways required for your application. ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet.
Open the catalog to page 1Specifications EtherNet/IP™ Specifications Specification Number of Class 3 Server Connections Supported PLC Types Supported Message Types Class 3 Client Connections Number of Class 1 I/O Connections I/O connection sizes Where Automation Connects™ Global Distribution ® CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write Command List Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count. Command Sets PLC-2/PLC-3/PLC5 Basic Command Set PLC5 Binary Command Set PLC5 ASCII Command Set SLC500...
Open the catalog to page 2Hardware Specifications Specification Power Supply Operating Temperature 24 VDC nominal 10 to 36 VDC allowed Positive, Negative, GND Terminals 24 VDC nominal @ 300 mA 10 to 36 VDC @ 610 mA maximum -25°C to 70°C (-13°F to 158°F) Storage Temperature Shock Vibration Relative Humidity Current Load Dimensions (H x W x D) 5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm LED Indicators Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), EtherNet/IP™ Class I or Class III Connection Status (EtherNet/IP Only) Module Status (MS), Module Configuration Status...
Open the catalog to page 3All PROSOFT catalogs and technical brochures
-
Automotive Solutions
3 Pages
-
Soluciones de Minerìa
5 Pages
-
PSW-PWD
2 Pages
-
5202-MNET-DFCM4
2 Pages
-
PS-QS-1x10-0117
1 Pages
-
PTQ-PDPMV1
3 Pages
-
PTQ-HART
3 Pages
-
RLXIB-IHN
2 Pages
-
RLXIB-IHN-W(C)
3 Pages
-
RLXIB-IHW
2 Pages
-
RLXIB-IHW-66
2 Pages
-
RLXIC-EH
2 Pages
-
RLXIC-EV
2 Pages
-
RLXIC-SG
2 Pages
-
RLXIC ST
2 Pages
-
RLXIC-SV
2 Pages
-
TermLinx
2 Pages
-
ProSoft i-View
1 Pages
-
ProSoft Wireless Designer
2 Pages
-
AFC Manager
2 Pages
-
RadioLinx OPC Server
2 Pages
-
ControlScape
2 Pages
-
PROFIBUS comDTM
2 Pages
-
PROSOFT.fdt
3 Pages
-
EZ-ASCE
2 Pages
-
WRC_CANR Series
2 Pages
-
WRC_CANX Series
2 Pages
-
RLX2_IHW
2 Pages
-
RLX2_IHNF
3 Pages
-
IMC-BHx-AC
2 Pages
-
WRC-CANR-DF
2 Pages
-
The Camisea Pipeline Flyer
2 Pages
-
Water Flows in Iraq
2 Pages
-
Packaging Brochure
4 Pages
-
Message Manager Flyer
1 Pages
-
Intelligent Cellular Flyer
2 Pages