HART Interface Used in Oil Production Flyer
2Pages

{{requestButtons}}

Catalog excerpts

HART Interface Used in Oil Production Flyer - 1

HART Interface Used in In an effort to increase production and reduce costs, the Venezuelan national oil company PDVSA recently purchased a new interface module, which will allow them to communicate between Allen- Bradley ControlLogix using DF1 and the HART protocol. Approximately 40 new HART Multidrop (8 channel) Serial Port Interface Modules from ProLinx Communication Gateways, Inc. will be installed in their crude oil production units in eastern Venezuela. The ProLinx HART modules allow up to 8 channels of multidrop HART communications (theoretical support for up to 120 instruments such as Mass Flow Meters, Differential Pressure Transmitters, Absolute Pressure Transmitters and Temperature Transmitters). It also provides full access to the digital configuration, diagnostics and maintenance information in each connected transmitter. "Since the ProLinx 4127 HART module allows one DF1 port to connect to 8 HART channels, this interface provides maximum efficiency for HART networks," said Franco Melchiorre, Latin American Regional Sales Manager for ProLinx Communication Gateways, Inc. "PDVSA has accepted the performance of this module, and are very pleased with the performance during factory tests." Specifications for the ProLinx HART mo dule in • 8 channel implementation with multidrop cap of 15 HART devices on each port ASIA PACIFIC | AFRICA | EUROPE | MIDDLE EAST | LATIN AMERICA | NORTH AMERICA

Open the catalog to page 1
HART Interface Used in Oil Production Flyer - 2

HART Interface Used in Oil Productio Electric Actuators Two Wire Control Systems (Tank Farms and Pump Stations) Control Room Tank Area Pump Building Electric Actuators Network From Pump Control Valves • Each channel is individually configurable • Up to 100 commands can be defined for each port • Supports the HART channel as a Master • Uses the Bell 202 standard frequency shift keying (FSK) signal to communicate on 1200 baud • Dual-master possibility on the network • 14 Universal HART commands and 30 Common Practice HART commands supported According to Ron Helson, Director of the HART...

Open the catalog to page 2

All PROSOFT catalogs and technical brochures

  1. PSW-PWD

    2 Pages

  2. PTQ-PDPMV1

    3 Pages

  3. PTQ-HART

    3 Pages

  4. RLXIB-IHN

    2 Pages

  5. RLXIB-IHW

    2 Pages

  6. RLXIB-IHW-66

    2 Pages

  7. RLXIC-EH

    2 Pages

  8. RLXIC-EV

    2 Pages

  9. RLXIC-SG

    2 Pages

  10. RLXIC ST

    2 Pages

  11. RLXIC-SV

    2 Pages

  12. TermLinx

    2 Pages

  13. AFC Manager

    2 Pages

  14. ControlScape

    2 Pages

  15. PROSOFT.fdt

    3 Pages

  16. EZ-ASCE

    2 Pages

  17. RLX2_IHW

    2 Pages

  18. RLX2_IHNF

    3 Pages

  19. IMC-BHx-AC

    2 Pages

  20. WRC-CANR-DF

    2 Pages