Catalog excerpts
LET’S TALK 317-335-2602 * PROPORTION-AIR * BRGP0607E
Open the catalog to page 1Analog monitor Standard Precision pressure control vacuum to 1000psi (69 bar) Adjustable Zero/Span/Hysteresis IP65 enclosure allows it to endure the elements and be washed down without harm Unaffected by supply pressure changes Power and status indicator LED’s Fast, Accurate, and Precise High Pressure Control Media In this application a GP-Series high pressure control valve is being used to control the pressure in a catheter burst test. Test results are being provided to the controller via the GP analog monitor feedback signal. In this application a Proportion-Air GP high pressure device is...
Open the catalog to page 2GENERAL SPECIFICATIONS & PERFORMANCE CHARACTERISTICS ELECTRICAL Supply Voltage Supply Current Command Signal Voltage (differential) Current (differential) Analog Monitor Output Voltage Current (Sourcing) TTL Satisfied Not-Satisfied 2nd Loop Input 110% of full scale calibration 20 micron (supplied with unit) ±0.25%F.S. ±0.3%F.S. ±0.2%F.S. 1/8 inch NPT Female (1/8 inch BSPP Optional) 3 in³ Brass 3.75 LBS (1.75 KG) S.S. 3.73 LBS (1.73 KG) 6 pin molded 16 gauge wire Inlet Pressure Pressure Range (1) (2) Flow Rate Filtration Required Accuracy (Pressure) Accuracy (Monitor) Hysteresis (3) Port...
Open the catalog to page 3ORDERING INFORMATION SERIES GP=1/8” NPT GX=1/8”NPT Cleaned for O2 Service GL=1/8” BSPP GN=1/8” BSPP Cleaned for O2 Service COMMAND SIGNAL E = 0-10 VDC I=4-20mADC (both differential) A=Absolute G=Gauge MINIMUM CALIBRATED PRESSURE RANGE (PSI) MAXIMUM CALIBRATED PRESSURE RANGE (PSI) MANIFOLD MATERIAL B=Brass S-303 Stainless A ELECTRICAL CONNECTOR A=6 pin Brad Harrison standard ORIFICE SIZE 1=0.012 inch 2=1/32 3=3/64 Factory determined MONITOR SIGNAL E=0-10VDC C=4-20mAD (sourcing) 1 = SINGLE LOOP 2 = DUAL LOOP VALVE WETTED PARTS I= Urethane/Viton standard H6DC6 6 Pin 6 Foot Power Cord Required...
Open the catalog to page 4All Proportion-Air catalogs and technical brochures
-
High Pressure
4 Pages
-
ISF1
8 Pages
-
DS
4 Pages
-
SELECT 6 POWER SUPPLY
2 Pages
-
RQ-02
2 Pages
-
RG873V
2 Pages
-
RM-SERIES VOLUME BOOSTERS
2 Pages
-
PM-4 DIGITAL INDICATOR
1 Pages
-
PM-3 DIGITAL INDICATOR
1 Pages
-
FPP SERIES IN-LINE FILTER
1 Pages
-
F-SERIES
8 Pages
-
F-SERIES FLOW CONTROLLER
12 Pages
-
DC2
2 Pages
-
DQB1
8 Pages
-
QPV1
12 Pages
-
MPV1
12 Pages
-
R-Series Volume Boosters
2 Pages
-
RG0003 WATER REGULATOR
1 Pages
-
Product Catalogue
24 Pages
-
PSR Series
4 Pages
-
Air flow control
12 Pages
-
BB2/PSR & QB2/PSR
8 Pages
-
QB3H
2 Pages
-
QB4 PRESSURE CONTROL VALVE
5 Pages
-
US1 ULTRASONIC SENSOR
1 Pages
-
PS300 POWER SUPPLY
1 Pages
-
V ELECTRO-PNEU. FLOW VALVE
4 Pages