Overview: The Proportion-Air F-Series is a line of flow transducers designed for real-time measurement of compressed gases. It utilizes differential pressure technology to provide accurate flow readings, converting pressure changes across a venturi into a linear analog output signal.
Key Features:
  • Available in seven different pipe sizes with low pressure drop.
  • Pressure compensated options and various connector options available.
  • Analog differential pressure sensor for real-time measurement.
  • IP65 housing for rugged environments.
  • Flow ranges from 2-20 SCFH to 25-250 SCFM.
Functional Description: The F-Series can be mounted in any position, has a response time of less than 10ms, and contains no moving parts. It is suitable for a wide range of inert gases and provides an analog output proportional to the measured flow.
Models:
  • FR Model: Regulated flow monitor using differential pressure for mass flow indication.
  • FP Model: Pressure compensated flow monitor with an absolute pressure sensor for density correction.
  • FA Model: Atmosphere flow monitor for venting applications.
Specifications:
  • Electrical: Power requirement of 15-24VDC, analog output of 1-10VDC or 5.6-20mA.
  • Mechanical: Maximum inlet pressure of 165 PSIA, accuracy of +/- 4% F.S., and a shock rating of 25G.
  • Physical: Operating temperature range from 32ºF to 122ºF, IP65 actuator housing rating.
Performance Characteristics: The F-Series provides linear output characteristics and is effective in correcting flow output signals for varying supply pressures. It is suitable for applications requiring rapid response and high accuracy.
Applications: The F-Series is used in automotive radiator testing and compressor performance plotting, among other applications.
Ordering Information: The F-Series can be customized based on type, port size, output signal, set pressure, maximum flow, flow units, electrical connection, media, and thread type.
Warranty: Proportion-Air offers a one-year warranty against defects in material or workmanship, with limitations on liability for improper installation or filtration.
Safety Warning: Installation and use should be supervised by qualified personnel to avoid risks of injury or death.
See more

Catalog excerpts

F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-1

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:11.00pt "Arial", sans-serif; } .font2 { font:14.00pt "Arial", sans-serif; } .font3 { font:35.00pt "Microsoft Sans Serif", sans-serif; } F-SERIES ELECTRO-PNEUMATIC EL OW MONITOR * Real time flow measurement * Idal for use In active flow controi * Diffrer) tial pressure technology * Pressure compensated models available * Flow ranges as low as 2-20 SCFH * Flow ranges as high as 25-250 SCFM Shown with optionai digital disptay

 Open the catalog to page 1
F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-2

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:10.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } THE INSIDE STORY OF THE F-SERIES: Response Time < 10ms Analog Differential Pressure Sensor for Real Time Measurement Analog Output = Measured Flow Many Connector Options IP65 Housing Pressure Compensated Option Available Venturi Style Orifice No Lead in Pipe Required Low Pressure Drop Available in Seven Different Pipe Sizes No Moving Parts Wide range of inert gases Mounts in Any Position...

 Open the catalog to page 2
F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-3

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:9.00pt "Arial", sans-serif; } .font5 { font:10.00pt "Arial", sans-serif; } .font6 { font:11.00pt "Arial", sans-serif; } .font7 { font:18.00pt "Arial", sans-serif; } .font8 { font:7.20pt "Times New Roman", serif; } .font9 { font:10.00pt "Times New Roman", serif; } Proportion-Air's F-Series product is available in flow ranges from...

 Open the catalog to page 3
F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-4

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:10.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } F-SERIES GENERAL SPECIFICATIONS & PERFORMANCE CHARACTERISTICS ELECTRICAL MINIMUM TYPICAL MAXIMUM Power Requirement 15VDC - 24VDC Supply Current - 80mA - Analog Output Voltage 1VDC - 10VDC Current Sinking 5.6mA - 20mA Sourcing 5.6mA - 20mA MECHANICAL MINIMUM TYPICAL MAXIMUM MAXIMUM INLET PRESSURE 1 30 PSIA - 165 PSIA 2.07 Bar Absolute - 11.38 Bar Absolute CALIBRATED FLOW RANGE - See CHART...

 Open the catalog to page 4
F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-5

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:7.00pt "Microsoft Sans Serif", sans-serif; } .font6 { font:4.00pt "Palatino Linotype", serif; } F-SERIES PERFORMANCE CHARACTERISTICS LINEARITY CHART 1 This chart shows linear characteristics of the F-Series Use CHART 1 to select the appropriate port size flow monitor with a signal output...

 Open the catalog to page 5
F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-6

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } .font3 { font:18.00pt "Arial", sans-serif; } .font4 { font:49.00pt "Arial", sans-serif; } F-SERIES TYPICAL APPLICATIONS RADIATOR TESTING Quick Disconnect Automotive Radiator H h To quickly dtermine that the flow passages of the radiator are adequately formed, the radiator is connected to a regulated supply and the F-Series provides immediate flow rate. COMPRESSOR TESTING 100 Controller...

 Open the catalog to page 6
F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-7

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:49.00pt "Arial", sans-serif; } .font5 { font:7.20pt "Times New Roman", serif; } F-SERIES DIMENSIONS DIMENSIONS ARE FOR REFERENCE USE ONLY Inches (mm) 0.2z[»5.6] thru (2 plc's) DIMENSION LEGEND/PER PORT SIZE DIM "A" DIM "B" INCHES/MM DIM "C" INCHES/MM 1/4 NPTF/BSPP 1.00/25.4 .375/9.5 3/8 NPTF/BSPP 1.50/38.1 .75/19.1 1/2 NPTF/BSPP...

 Open the catalog to page 7
F-SERIES ELECTRO-PNEUMATIC FLOW MONITOR-8

BRFS05-1201E table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:10.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:12.00pt "Arial", sans-serif; } .font5 { font:18.00pt "Arial", sans-serif; } .font6 { font:19.00pt "Arial", sans-serif; } CLOSED LOOP FLOW CONTROL OPTIONS F-Series flow monitor coupled to various Proportion Air, Inc controls to provided closed loop flow control. DF-Series with FQPV FLOW CONTROL APPLICATIONS LESS THAN 1 SCFM lBComsmju^...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.