1. Catalogs
  2. Promstahl WorldWide
  3. Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions

Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions

Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions
1 / 15 PagesView full catalog

Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions

Product catalog summary
Installation Instructions Overview
This document provides detailed installation instructions for the loading ramp with a telescopic lip leveller, type PAT. It includes specifications, necessary tools, transportation methods, installation procedures, and safety precautions.

General Information
The installation requires specific tools such as welding equipment (ESAB caddy 200 or similar) and lifting equipment like a forklift or crane with a minimum load capacity of 30 kN. Electrical connections require specific cables and must be handled by authorized personnel.

Electrical Preparations
Electrical setup involves a mains supply of 3/N/PE AC 50 Hz, 400 V/CEE 16 A, and a motor power of 1.5 kW. The wire conduit should have a minimum internal diameter of 50 mm.

Installation Tools and Elements
Various components are listed for different nominal lengths (NL) of the dock leveller, with specific quantities and sizes detailed for each part.

Transporting the Loading Ramp
Instructions are provided for transporting the ramp using a forklift or crane, with specific guidelines based on the nominal length of the ramp.

Installation of the Loading Ramp
Procedures are outlined for installing the ramp with or without rear supports. Specific configurations and part numbers are provided for different ramp sizes.

Mounting of the Loading Ramp
Details are given for mounting the ramp, again with options for configurations with or without rear supports.

Electrical Connections
Electrical connections must be made by an authorized electrician following the wiring diagram. Safety precautions are emphasized, including ensuring the dock leveller is dead and secured against restart before any electrical work.

Option: Buffers
Additional components for buffers are listed, including specific part numbers and quantities.

Safety and Maintenance
Safety warnings are highlighted throughout, including the importance of using lifting equipment in good working order and observing accident prevention regulations. Maintenance instructions include repainting guidelines for welded and damaged surfaces.
See more

Catalog excerpts

Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-1

Installation instructions Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 1 / 15 Installation instructions Loading ramp with telescopic lip leveller Type: PAT Load capacity: see rating plate Contact: We reserve the right to alter technical specifications.

 Open the catalog to page 1
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-2

Installation instructions Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 2 / 15 We reserve the right to alter technical specifications.

 Open the catalog to page 2
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-3

Installation instructionsLoading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 3 / 15 Installation tools The following tools are needed for the installation: • Welding equipment: ESAB caddy 200 (5-200A) or similar equipment • Welding rod: ESAB OK 48.00 3,25 or similar equipment Lifting equipment • Forklift truck: load capacity of 35 kN, fork length: 2000 mm, or • Crane: load capacity of 30 kN min. in the required range of operation. Electrical connections • cables: 7x 0.75 mm2 Danger! Before starting any work on the electrical equipment, the dock leveller must...

 Open the catalog to page 3
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-4

Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 2. Wire conduit. Minimum internal diameter 50 mm, Angled pipe < 45° (by others) 3. Door/dock leveller light switch (optional) Loading ramp (Dock leveller NL (nominal length) < 2450) We reserve the right to alter technical specifications.

 Open the catalog to page 4
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-5

Loading ramp with telescopic lip leveller type PAT Loading ramp (Dock leveller NL > 2450) 7 1x We reserve the right to alter technical specifications.

 Open the catalog to page 5
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-6

L, Inn f \ A A Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 * by others ** quantity - see table on page 11 Option: Loading ramp with rear supports Option: Buffers We reserve the right to alter technical specifications.

 Open the catalog to page 6
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-7

Installation instructions Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 7 / 15 Transporting of the loading ramp Transport using a forklift NL ≤ 2450 Transport using a forklift NL > 2450 (without side elements) We reserve the right to alter technical specifications.

 Open the catalog to page 7
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-8

Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Transport using a crane NL < 2450 Transport using a crane NL > 2450 (without side elements) We reserve the right to alter technical specifications.

 Open the catalog to page 8
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-9

Installation instructions Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 9 / 15 Installation of the loading ramp Installation with rear supports (optional) We reserve the right to alter technical specifications.

 Open the catalog to page 9
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-10

Installation instructions Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 10 / 15 Installation without rear supports We reserve the right to alter technical specifications.

 Open the catalog to page 10
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-11

PROM Loading ramp with telescopic lip leveller type PAT

 Open the catalog to page 11
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-12

Installation instructions Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 12 / 15 Mounting of the loading ramp Mounting without rear supports Mounting with rear supports We reserve the right to alter technical specifications.

 Open the catalog to page 12
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-13

Installation instructions Loading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 13 / 15 Electrical connections We reserve the right to alter technical specifications.

 Open the catalog to page 13
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-14

Installation instructionsLoading ramp with telescopic lip leveller type PAT Version: 1.0.0 Date: 03.04.2013 Page: 14 / 15 We reserve the right to alter technical specifications.

 Open the catalog to page 14
Loading Ramp With Telescopic Lip Leveler PAT - Installation instructions-15

Loading ramp with telescopic lip leveller type PAT Option: Buffers We reserve the right to alter technical specifications.

 Open the catalog to page 15

All Promstahl WorldWide catalogs and technical brochures

  1. Imagefolder

    8  Pages

  2. CATALOG

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.