ProMinent® Product Catalogue 2018 - Volume 2: Measuring, control and sensor technology - 288 Pages

Add to MyDirectIndustry favorites
ProMinent® Product Catalogue 2018 - Volume 2: Measuring, control and sensor technology

Catalog excerpts

Issued by: ProMinent GmbH lm Schuhmachergewann 5-11 69123 Heidelberg Germany Phone +49 6221 842-0 info@prominent.com www.prominent.com Technical changes reserved. All previous catalogues and price lists are superseded with the release of this product catalogue. You can view our general terms and conditions on our homepage.

 Open the catalog to page 2

Product Catalogue Volume 2 1.0.1www.prominent.com Product Catalogue Volume 2 Measuring, Control and Sensor Technology Precision by design Precise sensor technology and high-performance measuring and control technology are the guarantee of process safety when metering liquid media. We deal with it in detail in Chapter 1! Discover a huge range of DULCOTEST® sensors for precise recording of different parameters in real time. The controllers in Chapter 2 will introduce consistent quality into your process. From the simple conversion of measuring signals to controllers optimised for complex,...

 Open the catalog to page 3

New Measuring, Control and Sensor Technology Products 1.0.1www.prominent.com New Measuring, Control and Sensor Technology Products Sensor for free chlorine CLO 1-CAN-P Sensor for the measurement of free chlorine in clear water even when using electrolysis processes for disinfection, up to 45 °C (1 bar) or 8 bar (25 °C). For use on controllers with CAN-bus connection. Measured variable: free chlorine, no significant cross sensitivity to combined chlorine (chloramines) Use with return of the sample water to the process line Use at higher pressures Minimisation of faults by electrolysis...

 Open the catalog to page 5

New Measuring, Control and Sensor Technology Products Conductivity sensor CCT 1-mA Sensor for the measurement of electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and factory-calibrated 4...20 mA output signal. For operation with the controllers diaLog DAC, AEGIS® II, DULCOMARIN®. ࡯ Measured variable: electrolytic conductivity up to 20 mS/cm ࡯ Reliable 4-20 mA output signal for the flexible connection to different measuring devices ࡯ Integrated temperature sensor for temperature compensation replaces separate temperature...

 Open the catalog to page 6

Measuring, Control and Sensor Technology 1 Sensor Technology DULCOTEST®    1-1 1.0    Overview of Sensor Technology DULCOTEST®    1-1 1.1    Sensor Technology DULCOTEST® Measuring Principles    1-5 1.1.1 Three Measurement Priciples for Reliable Water Treatment 1-5 1.1.2 Potentiometry - Measures an Electrode's Potential in a Sample Solution    1-5 1.1.3 Amperometry - A Current Measurement Used to Determine the Concentration of Predetermined Dissolved Solids in Aqueous Solutions    1 -6 1.1.4 Advantages of DULCOTEST® Amperometric Sensors at a Glance    1-7 1.2    pH, ORP, Fluoride and...

 Open the catalog to page 7

Contents Measuring, Control and Sensor Technology page 2.1.7    Application Examples, Waste Water Monitoring    2-15 2.1.8    Application Examples in the Food Industry    2-17 2.1.9    Odour Reduction Application Examples (Clarification Plants) 2-18 2.2.2 Identity Code Ordering System DULCOMETER® D1Cb, Wall Mounting    2-21 2.2.3 Identity Code Ordering System DULCOMETER® D1Cc, Control Panel Mounting    2-22 2.2.4 D1Ub Identity Code Ordering System, Subsequent Function Upgrade for D1Cb    2-24 2.2.5 D1Uc Identity Code Ordering System, Subsequent Function Upgrade for D1Cc    2-25 2.2.7...

 Open the catalog to page 8

Measuring, Control and Sensor Technology 2.5.4    Chlorine sensors for DULCOMARIN® II and 3    2-85 2.6.2    Identity code ordering system for AEGIS II cooling 2.7 Controller with Integral Metering Pump    2-90 2.7.1    Controller with Integral Metering Pump    2-90 2.8.2    Identity Code Ordering System for Transmitter DMTa    2-93 2.8.3 Application Example: Measurement of Free Chlorine with Connection to a PLC    2-94 2.9.1    Portable Meter Portamess® - Measured Variable pH/ORP 2-98 2.9.2    Portable Meter Portamess® - Measured Variable 2.10    Accessories for Measuring and Control...

 Open the catalog to page 9

Contents Measuring, Control and Sensor Technology page 4.4    Metering System DULCODOS®    Pool Professional    4-9 4.4.1    Metering System DULCODOS® Pool Professional    4-9 4.5.1    Maintenance Kits for Metering Pumps    4-13 4.5.2    Maintenance Kits for Measured Variables    4-13 4.6.1    Portable Meter Portamess® - Measured Variable    pH/ORP 4-14

 Open the catalog to page 10

Selection GuideSelection Guide for pH Sensors DULCOTEST® Medium Temperature / pressure Sensor type Typical application Solid residues, turbidity max. 80 °C / 6 bar    RHER Solid matter, non-translucent Cooling water, waste water Suspensions, sludge, emulsions Note: All DULCOTEST® pH and ORP sensors are made using lead-free glass (RoHS-compliant) Sensor Technology DULCOTEST® 1.1.2018

 Open the catalog to page 11

Sensor Technology DULCOTEST® 1.0 Overview of Sensor Technology DULCOTEST®Selection guide for DULCOTEST® amperometric sensors Measured variable Applications    Graduated Connection to Sensor type    See measuring    DULCOMETER®    page

 Open the catalog to page 12

Conductivity sensor selection guide Conductivity > 20 mS/cm or residue-forming medium or chemically aggressive medium? Series ICT 2 Installation in the process line: with stainless steel flange accessory For immersion with accessory: Immersion fitting IMA - ICT 2 Installation in the process line? Type ICT 1 Successor ICT5 for installation in a pipe Type ICT 1-IMA Successor ICT5 for immersion Sensor Technology DULCOTEST®

 Open the catalog to page 13

All ProMinent GmbH catalogs and technical brochures

Archived catalogs