Group: Process Insights
Catalog excerpts

ONLINE WATER ANALYZERS PRODUCT DATASHEET QuickTOCtrace™ For continuous TOC monitoring in ultra-pure water • Pure water • Ultra pure water • Process water • Boiler feed water
Open the catalog to page 1
The Measuring System For Ultra Pure Water The lowest organic impurities are detected fast and cost-effectively – for optimal process control of challenging industries. The QuickTOCtrace™ is suitable for the determination of TOC in ultra pure and purified water – especially in the manufacture of semi-conductors and pharmaceutical industries as well as in any process, where ultra pure water is essential. In order to ensure the high product quality and to guarantee process security, the fast and reliable monitoring of ultra pure water is of the utmost importance. This applies in particular to...
Open the catalog to page 2
Quality Assurance And Process Security Through Continuous Monitoring The monitoring of the above mentioned parameters is of great importance with regard to quality assurance. In the manufacture of semiconductors, particles and organic/inorganic components can have a significant effect on sensitive photo-lithographic processes. Biological growth, often promoted by an increased TOC content, can contribute to unintended chemical processes. In the pharmaceutical industry, the assurance of product quality is paramount. Depending on the areas of application, WFI is used for injections, highly...
Open the catalog to page 3
Especially for challenging applications that require reliable detection within seconds of lowest impurities in pure water. Continuous TOC Measurement By Means Of UV Oxidation And Differential Conductivity Measurement The QuickTOCtrace is an online system working on the basis of the traditional continuous flow process with conductivity detection. UV oxidation using the “direct surface” process guarantees highest precision thanks to highly sensitive conductivity sensors. With integrated temperature sensors, all data that is relevant of the measurement of TOC are monitored and processed. The...
Open the catalog to page 4
Fig. 1 1) Sample preparation 2) UV-Oxidation of organic carbon to CO2 by Hydroxyl-Radicals 3) etermination of the D TOC contamination a) easurement of M conductivity prior to oxidation (LF 1) b) Measurement of conductivity after oxidation (LF 2) c) Calculation LF 2 – LF 1 = TOC UV Oxidation: Formation Of Free Radicals Oxidation using the “direct surface” procedure – thus without the use of chemical oxidants – has proven very effective in the measurement of very small TOC concentration, commonly found in ultra-pure water. When water containing O2 is exposed to UV radiation (185 nm, 254 nm),...
Open the catalog to page 5
TECHNICAL DATA Measurement Technique and Sample Preparation Measurement Method UV oxidation (partial) with difference-conductivity measurement Measurement Ranges Response Time Sample Streams Dimensions and Weight Housing Stainless Steel IP 20, IP 54 (optional) Electric Specifications Power Supply Analogue Output Equipment Devices and Data Output 8“ touch screen graphic display, backlit Integrated computer for control Operating system Windows 7 embedded Self explanatory software incl. Viewer Automatic System Suitability Test (SST) Accessories and Options Calibration solutions, SST-Kit, IQ/OQ...
Open the catalog to page 6
We offer application specific analyzers developed by our research and development team. In addition, we maintain close contact with our clients and continually analysis the exact problem areas of every application. Since the availability of our devices is a deciding criteria, they are constructed in a very user-friendly way. All important areas require little effort to be accessed and the protective housing offers additional safety. After Sale Support Servicing is carried out by our qualified partners worldwide. Technical support, via telephone or email is available at all times....
Open the catalog to page 7
ONLINE WATER ANALYZERS GAIN REAL-TIME INSIGHT INTO YOUR PROCESS Process Insights manufactures and delivers premium sensors, monitors, detectors, analyzers, instrumentation, and software that are mission-critical to keep your operations, personnel, and the environment safe – every day across the globe. Get the most reliable, precision analytical technologies available on the market today. We will work to match your needs and budget, and provide the optimal, and most stable process analysis solution for your application. CENTERS OF EXCELLENCE | PROVIDING PROVEN SOLUTIONS Process Insights is...
Open the catalog to page 8All Process Insights catalogs and technical brochures
-
HALO Max QCL™
4 Pages
-
innovative water solutions
24 Pages
-
SERIES 2000
5 Pages
-
QuickTONultra
4 Pages
-
573 Dew Point Mirror™
8 Pages
-
T12
4 Pages
-
SERIES 3520™
4 Pages
-
SERIES 3500™ & 3510™
4 Pages
-
SERIES 3000™
4 Pages
-
SERIES 2520™
4 Pages
-
SERIES 2500™ & 2510™
4 Pages
-
ZRO 2000™
4 Pages
-
OXY-SEN™
4 Pages
-
SERIES 1300™
4 Pages
-
PCM 5000™
2 Pages
-
PCM 1000™
4 Pages
-
EVM™
4 Pages
-
Diamond 20™
4 Pages
-
Diamond MX™
4 Pages
-
Hydrocarbon SmartSystem
8 Pages
-
RefinIR™
4 Pages
-
RovIR™
4 Pages
-
Fiber Optic Cable
4 Pages
-
Turbidity Process Flow Cell
4 Pages
-
Teflon Process Flow Cell
4 Pages
-
Gas Process Flow Cell
4 Pages
-
Axial Process Flow Cell
4 Pages
-
G-SST™
4 Pages
-
RTD-SST
4 Pages
-
O-SST
4 Pages
-
SST
4 Pages
-
ClearView
4 Pages
-
LAB 508 UV-VIS
8 Pages
-
508 UV-VIS
8 Pages
-
LAB NIR-O
8 Pages
-
NIR-O™ PROCESS ANALYZER
8 Pages
-
QuickTOCuv™
4 Pages
-
QuickCODlab™
8 Pages
-
ToxAlarm™
4 Pages
-
NitriTox™
4 Pages
-
QuickTOCeco™
4 Pages
-
QuickTOCairport™
6 Pages
-
RGA
6 Pages
-
MB
8 Pages
-
HRQ
6 Pages
-
APIMS
2 Pages
-
MAX-QMS
2 Pages
-
MAX300-EGA
8 Pages
-
PRODUCT DATASHEET MAX300-LG
4 Pages
-
MAX300-CAT
4 Pages
-
MAX300-BIO
8 Pages
-
MAX300-AIR
8 Pages
-
MAX300-RTG™ 2.0
8 Pages
-
MODEL ESS-SCVP™
8 Pages
-
HDT
8 Pages
-
XDT
8 Pages
-
XPDM
8 Pages
-
LPDT2
4 Pages
-
Spark H2 O in CO2
6 Pages
-
HALO KA H2O
3 Pages
-
HALO OK
8 Pages
-
HALO H2O in N2O
2 Pages
-
HALO H2
4 Pages
-
HALO 3 NH3
3 Pages
-
HALO 3 HCI
3 Pages
-
HALO 3 CH4
3 Pages
-
HALO 3 H2O
4 Pages
-
HALO 3 D2O/HDO
4 Pages
-
HALO 3 CO2
4 Pages
-
HALO 3 CO
2 Pages
-
HALO 3 CH2O
2 Pages
-
HALO KA Max
4 Pages
-
VeraSpec™ APIMS
2 Pages
-
973
8 Pages
-
573
8 Pages
-
473 Dew Point Hygrometer
8 Pages
-
Zircomat
8 Pages
-
9610
8 Pages
-
9800 Calorimeter
4 Pages
-
Flare Gas Analyzers
1 Pages
-
PRODUCT BROCHURE MAX300-LG
8 Pages
-
MAX300-RTG 2.0
8 Pages