Group: Process Insights
Catalog excerpts
PRODUCT BROCHURE Fast Response Process Control Stable Measurement • Real-Time Gas Analysis • Catalysis Monitoring • Trace Gas Detection • Environmental Research • Multipoint Process
Open the catalog to page 1Introducing the MAX300-LG High Performance Quantitative Gas Analyzer The MAX300-LG™ brings an unmatched combination of speed, sensitivity and precision to continuous, quantitative gas analysis. Based on cutting-edge quadrupole mass spectrometer technology, the MAX300-LG has the dynamic range to measure component concentrations from 100% down to the low parts per trillion (ppt). It provides a full-composition update every few seconds to measure changes in dynamic chemical processes. Laboratory Gas Analyzer Features • Measures any gas or vapor sample • Complete quantitative sample composition...
Open the catalog to page 2Sensitivity, Precision, Flexibility Simply use the software to select the gases to measure, or the mass range to scan, and the MAX300-LG is configured to monitor a new reaction or process. Gas and Vapor Analysis Catalysis Reaction Monitoring and Kinetics TPD/TPR/TPO Combustion Studies Process Development Vapor Deposition Gas Phase Synthesis Pilot Scale Process Control Evolved Gas Analysis Bioreactor Monitoring Organic Chemistry Breath Analysis Environmental Analysis Fuel Cell Studies Alternative Fuels Gasification Air Monitoring Pure Gas Analysis Trace Contamination Pharmaceutical Solvents...
Open the catalog to page 3We’re Ready for Your Sample Successful gas analysis begins with the right sample interface. Decades of collaboration with research and industry have generated a host of inlet configurations to protect your sample in transit to the detector, and ensure you are getting the data you need out of your process. Sample Inlet Configurations: • Gate valves for samples with a fixed pressure < 5 Torr • Capillaries for samples with a fixed pressure > 5 Torr • Automated Multiport stream selection - 4, 16, 31, 46, 60+ • Differentially pumped inlets for fast clearing • Automated pressure control for...
Open the catalog to page 4System Specifications Detectable compounds: Any gas or vapor sample Detection range: – Faraday detector: 100% – 5 ppm – Electron multiplier: 100% – 5 ppb* – Membrane inlet: 100% – 10 ppt* Analysis rate: 0.005 – 16 seconds per component – User selectable Number of components: Unlimited Number of analysis routines: Unlimited Number of user configurable data tags: Unlimited Precision: <0.05% RSD over 24 hours** Stability: <0.5% RSD over 30 days** Ionization energy control for reduced fragmentation Automated detector switching within a single scan Filaments: Two, one active and one spare with...
Open the catalog to page 6Power Supply Options: • 110 vAC +/- 10% vAC 50/60 hz, 10 Amp Circuit • 230 vAC +/- 10% vAC 50/60 hz, 10 Amp Circuit Power Consumption: • Nominal 700 Watts Weight: • Approximately 165 lbs (75 kg) • Optional cart: 40 lbs (18 kg) Ambient Requirements: • 55°F to 80°F (13°C to 27°C) • Area Classification: General Purpose Relative Humidity: • 0-90% non-condensing Data System and Communications: • System control interface options: Ethernet or USB • Login security levels: Administrator, User, Viewer • External communications: Ethernet, Modbus serial, digital I/O, analog I/O, OPC 38.25” (972)...
Open the catalog to page 7GAIN REAL-TIME INSIGHT INTO YOUR PROCESS Process Insights manufactures and delivers premium sensors, monitors, detectors, analyzers, instrumentation, and software that are mission-critical to keep your operations, personnel, and the environment safe – every day across the globe. Get the most reliable, precision analytical technologies available on the market today. We will work to match your needs and budget, and provide the optimal, and most stable process analysis solution for your application. CENTERS OF EXCELLENCE | PROVIDING PROVEN SOLUTIONS Process Insights is committed to solving our...
Open the catalog to page 8All Process Insights catalogs and technical brochures
-
HALO Max QCL™
4 Pages
-
innovative water solutions
24 Pages
-
SERIES 2000
5 Pages
-
QuickTONultra
4 Pages
-
573 Dew Point Mirror™
8 Pages
-
T12
4 Pages
-
SERIES 3520™
4 Pages
-
SERIES 3500™ & 3510™
4 Pages
-
SERIES 3000™
4 Pages
-
SERIES 2520™
4 Pages
-
SERIES 2500™ & 2510™
4 Pages
-
ZRO 2000™
4 Pages
-
OXY-SEN™
4 Pages
-
SERIES 1300™
4 Pages
-
PCM 5000™
2 Pages
-
PCM 1000™
4 Pages
-
EVM™
4 Pages
-
Diamond 20™
4 Pages
-
Diamond MX™
4 Pages
-
Hydrocarbon SmartSystem
8 Pages
-
RefinIR™
4 Pages
-
RovIR™
4 Pages
-
Fiber Optic Cable
4 Pages
-
Turbidity Process Flow Cell
4 Pages
-
Teflon Process Flow Cell
4 Pages
-
Gas Process Flow Cell
4 Pages
-
Axial Process Flow Cell
4 Pages
-
G-SST™
4 Pages
-
RTD-SST
4 Pages
-
O-SST
4 Pages
-
SST
4 Pages
-
ClearView
4 Pages
-
LAB 508 UV-VIS
8 Pages
-
508 UV-VIS
8 Pages
-
LAB NIR-O
8 Pages
-
NIR-O™ PROCESS ANALYZER
8 Pages
-
QuickTOCtrace™
8 Pages
-
QuickTOCuv™
4 Pages
-
QuickCODlab™
8 Pages
-
ToxAlarm™
4 Pages
-
NitriTox™
4 Pages
-
QuickTOCeco™
4 Pages
-
QuickTOCairport™
6 Pages
-
RGA
6 Pages
-
MB
8 Pages
-
HRQ
6 Pages
-
APIMS
2 Pages
-
MAX-QMS
2 Pages
-
MAX300-EGA
8 Pages
-
PRODUCT DATASHEET MAX300-LG
4 Pages
-
MAX300-CAT
4 Pages
-
MAX300-BIO
8 Pages
-
MAX300-AIR
8 Pages
-
MAX300-RTG™ 2.0
8 Pages
-
MODEL ESS-SCVP™
8 Pages
-
HDT
8 Pages
-
XDT
8 Pages
-
XPDM
8 Pages
-
LPDT2
4 Pages
-
Spark H2 O in CO2
6 Pages
-
HALO KA H2O
3 Pages
-
HALO OK
8 Pages
-
HALO H2O in N2O
2 Pages
-
HALO H2
4 Pages
-
HALO 3 NH3
3 Pages
-
HALO 3 HCI
3 Pages
-
HALO 3 CH4
3 Pages
-
HALO 3 H2O
4 Pages
-
HALO 3 D2O/HDO
4 Pages
-
HALO 3 CO2
4 Pages
-
HALO 3 CO
2 Pages
-
HALO 3 CH2O
2 Pages
-
HALO KA Max
4 Pages
-
VeraSpec™ APIMS
2 Pages
-
973
8 Pages
-
573
8 Pages
-
473 Dew Point Hygrometer
8 Pages
-
Zircomat
8 Pages
-
9610
8 Pages
-
9800 Calorimeter
4 Pages
-
Flare Gas Analyzers
1 Pages
-
MAX300-RTG 2.0
8 Pages