PRODUCT DATASHEET LAB 508 UV-VIS™ UV-VIS Lab / Benchtop Spectrometer • Low level APHA color • Polymers: phosgene, inhibitor concentration • Films: thickness %T, %R • Chlorine gas concentration • Rare earth metals in mining tailing/metal motherload • Solvent concentration High sensitivity
Open the catalog to page 1
GUIDED WAVE 508 UV-VIS Analyzers: Process and Lab The LAB 508 UV-VIS™ analyzer uses a diode array spectrometer to collect spectral data from liquids, gases, and polymer-based films. The spectral data are interpreted by the analyzer software to determine the composition or physical characteristics of the material, all in real-time, and in challenging process environments. Two full spectrum UV-VIS analyzers are available, process online or a bench top for offline lab measurements. A comprehensive system includes the UV-VIS analyzer, one or more UV-VIS probes, fiber optic cables, and scanning...
Open the catalog to page 2
Calibration Transfer Allows Flexible Uses Process chemists, engineers, and researchers will appreciate the LAB 508 UV-VIS analyzer's flexibility to move from R&D testing, Pilot Plants, to full scale QC operations. In addition, the LAB 508 UV-VIS benchtop analyzer can be used for calibration development in support of a process 508 UV-VIS analyzer. A key aspect for UV-VIS spectrometric method development involves the issue of calibration transfer between analyzers. This is important if you are developing a calibration on a laboratory unit for use on a process unit. Multivariate calibrations...
Open the catalog to page 3
OmniLab Analysis Software OmniLab™ is a standalone software package controlling all aspects of the LAB 508 UV-VIS analyzer. It provides full control of analyzer operations; diagnostics, data manipulation, event logging, trend graphs and alarms, calibration model security, and control of inputs and outputs. OmniLab can be customized with "add-on scripts" to meet the needs of any process installation. Support for model formats from Solo (Eigenvector) and Pirouette (Infometrix) is available. Pre-and post-processing of spectral data is done by way of the Python™ scripting language. OmniLab...
Open the catalog to page 4
SST Single-Sided Transmission Lab Probe For the QC LAB For a complete laboratory measurement solution, our Gold Braze Sealed LAB SST™ probe was designed to work with the fiber optic-based LAB 508 UV-VIS Analyzer or other FT-NIR process spectrometers. The LAB SST probe’s high optical efficiency gives rise to spectral results that duplicate online process SST probe performance. This simplifies the creation of online calibration models from lab data and ensures that QC lab checks of online analyzer performance are more accurate. The reliable design of the LAB SST Probe is ideal for benchtop...
Open the catalog to page 5
Cuvette Holder Types Process Insights offers two styles of cuvette holder. The first is a traditional Single Cuvette Holder with an optional removable filter holder for easy system validation. The second style is the customizable Triple Cuvette Holder. Designed as a single unit it can accept up to three cuvettes simultaneously, the Triple Cuvette Holder is made to order. At the time of quotation, the required pathlengths for each of the slots is defined. This customizable design allows the holder to be compatible with standard NIR or UV cuvettes and disposal plastic cuvettes. If HPLC vials...
Open the catalog to page 6
Optional Accessories Process Insights Triple Cuvette Holder or traditional Single Cuvette Holder are optional accessories for laboratory work, calibration development or feasibility studies. Either style of cuvette holder works alongside the LAB 508 UV-VIS analyzer for collecting high quality spectral data. By using two or more cuvette holders or probes, various applications or software configurations can be tested without any sample contamination. Specifications: Design: Transmission Grating, High Sensitivity Diode Array Two (2) year limited warranty Light Source / Life: 2W pulsed Xenon...
Open the catalog to page 7
GAIN REAL-TIME INSIGHT INTO YOUR PROCESS Process Insights manufactures and delivers premium sensors, monitors, detectors, analyzers, instrumentation, and software that are mission-critical to keep your operations, personnel, and the environment safe – every day across the globe. Get the most reliable, precision analytical technologies available on the market today. We will work to match your needs and budget, and provide the optimal, and most stable process analysis solution for your application. CENTERS OF EXCELLENCE | PROVIDING PROVEN SOLUTIONS Process Insights is committed to solving our...
Open the catalog to page 8All Process Insights catalogs and technical brochures
-
HALO Max QCL™
4 Pages
-
innovative water solutions
24 Pages
-
SERIES 2000
5 Pages
-
QuickTONultra
4 Pages
-
573 Dew Point Mirror™
8 Pages
-
T12
4 Pages
-
SERIES 3520™
4 Pages
-
SERIES 3500™ & 3510™
4 Pages
-
SERIES 3000™
4 Pages
-
SERIES 2520™
4 Pages
-
SERIES 2500™ & 2510™
4 Pages
-
ZRO 2000™
4 Pages
-
OXY-SEN™
4 Pages
-
SERIES 1300™
4 Pages
-
PCM 5000™
2 Pages
-
PCM 1000™
4 Pages
-
EVM™
4 Pages
-
Diamond 20™
4 Pages
-
Diamond MX™
4 Pages
-
Hydrocarbon SmartSystem
8 Pages
-
RefinIR™
4 Pages
-
RovIR™
4 Pages
-
Fiber Optic Cable
4 Pages
-
Turbidity Process Flow Cell
4 Pages
-
Teflon Process Flow Cell
4 Pages
-
Gas Process Flow Cell
4 Pages
-
Axial Process Flow Cell
4 Pages
-
G-SST™
4 Pages
-
RTD-SST
4 Pages
-
O-SST
4 Pages
-
SST
4 Pages
-
ClearView
4 Pages
-
508 UV-VIS
8 Pages
-
LAB NIR-O
8 Pages
-
NIR-O™ PROCESS ANALYZER
8 Pages
-
QuickTOCtrace™
8 Pages
-
QuickTOCuv™
4 Pages
-
QuickCODlab™
8 Pages
-
ToxAlarm™
4 Pages
-
NitriTox™
4 Pages
-
QuickTOCeco™
4 Pages
-
QuickTOCairport™
6 Pages
-
RGA
6 Pages
-
MB
8 Pages
-
HRQ
6 Pages
-
APIMS
2 Pages
-
MAX-QMS
2 Pages
-
MAX300-EGA
8 Pages
-
PRODUCT DATASHEET MAX300-LG
4 Pages
-
MAX300-CAT
4 Pages
-
MAX300-BIO
8 Pages
-
MAX300-AIR
8 Pages
-
MAX300-RTG™ 2.0
8 Pages
-
MODEL ESS-SCVP™
8 Pages
-
HDT
8 Pages
-
XDT
8 Pages
-
XPDM
8 Pages
-
LPDT2
4 Pages
-
Spark H2 O in CO2
6 Pages
-
HALO KA H2O
3 Pages
-
HALO OK
8 Pages
-
HALO H2O in N2O
2 Pages
-
HALO H2
4 Pages
-
HALO 3 NH3
3 Pages
-
HALO 3 HCI
3 Pages
-
HALO 3 CH4
3 Pages
-
HALO 3 H2O
4 Pages
-
HALO 3 D2O/HDO
4 Pages
-
HALO 3 CO2
4 Pages
-
HALO 3 CO
2 Pages
-
HALO 3 CH2O
2 Pages
-
HALO KA Max
4 Pages
-
VeraSpec™ APIMS
2 Pages
-
973
8 Pages
-
573
8 Pages
-
473 Dew Point Hygrometer
8 Pages
-
Zircomat
8 Pages
-
9610
8 Pages
-
9800 Calorimeter
4 Pages
-
Flare Gas Analyzers
1 Pages
-
PRODUCT BROCHURE MAX300-LG
8 Pages
-
MAX300-RTG 2.0
8 Pages