Group: Process Insights
Catalog excerpts
PROCESS ANALYZER PRODUCT DATASHEET 508 UV-VIS™ UV-VIS Process Analyzer Spectrometer • Low-level APHA color • Polymers: phosgene, inhibitor concentration • Films: thickness %T, %R • Chlorine gas concentration • Rare earth metals in mining tailing/metal motherload • Solvent concentration High sensitivity
Open the catalog to page 1UV-VIS Process Analyzer The 508 UV-VIS™ process analyzer offers remote multi-channel UV-VIS spectroscopic analysis. It provides excellent signal-to-noise ratio, wavelength stability, NIST traceable wavelength calibration, and built-in diagnostics. Process engineers, operators, and researchers will appreciate the 508 UV-VIS analyzer's built-in capacity to add more sampling points (up to 4 total channels) within the same process or cross processes. This can be done in any combination, providing flexibility to invest in only the capacity required now, while minimizing future expansion costs....
Open the catalog to page 2Research-Grade Signal-to-Noise Ratio The 508 UV-VIS analyzer provides excellent signal-to-noise ratio, which means better sensitivity in your measurements. The 508 UV-VIS analyzer also provides excellent wavelength accuracy (NIST traceable) and superb wavelength repeatability. Options: • ouch screen computer for local process visualization and control (only on general purpose and T Z-purge package) • -Purge package: Class 1 Zone 2 Groups IIB+ H2 (pending certification) Z • -Purge package: Class 1 Zone 1 Groups IIB+ H2 (pending certification) X • olo_Predictor, Pirouette®, prediction engine...
Open the catalog to page 3OmniView Process Analysis Software OmniView is a standalone software package controlling all aspects of the 508 UV-VIS analyzer. It provides full control of analyzer operations; diagnostics, data manipulation, event logging, trend graphs and alarms, calibration model security, and control of inputs and outputs. Communications via MODBUS® TCP are included as standard. 4-20 mA analog signals are also supported with optional hardware. OmniView can be customized with "add-on scripts" to meet the needs of any process installation. Support for model formats from Solo (Eigenvector) and Pirouette...
Open the catalog to page 4Smart Choice The 508 UV-VIS analyzer is compatible with all our probes and flow cells which can be used in any combination required for your analytical needs. The 508 UV-VIS's ability to monitor multiple reactions or samples with high accuracy and reliability in multiple environments makes it a cost-effective smart choice. • L*a*b* and other color coordinates • Solvent recovery purity • Maleic acid in tetrahydrofuran (THF) • Trace (ppm level) impurities in wash water; Clean-In-Place • Polynuclear aromatics (PNA’s) in middle distillates • Phenol in cyclohexane • Sodium hypochlorite in bleach...
Open the catalog to page 5Both Process and Lab Analyzer Options In addition to the process 508 UV-VIS analyzer, we also offer a bench top analyzer for offline lab measurements. The LAB 508 UV-VIS™ was engineered to enable calibrations developed in the lab to be moved directly to a 508 UV-VIS process analyzer in the field. This allows seamless and precise data transfer with high accuracy and reliability. This reliable bench top analyzer is a single channel UV-VIS (200-800 nm) spectrometer. Calibration Transfer Allows Flexible Uses Process chemists, engineers, and researchers will appreciate the LAB 508 UV-VIS...
Open the catalog to page 6Specifications: Design: Transmission Grating, High Sensitivity Diode Array Two (2) year limited warranty Light Source / Life: 2W pulsed Xenon Lamp, > 2 year replace 10K hour life MTBF Fiber Optic Cables: Fiber Optic Cable Connectors: Model Engine: Solo (PLS_Toolbox) or Piroutte Modbus TCP over ethernet or external OPTO 22 analog and digital I/O Software Required: OmniView Process Analysis Software Wavelength Accuracy: Minimum Step Size: Photometric Noise: Photometric Stability (Baseline): Scan Time: RoHS Compliant: Dimensions (General Purpose): Enclosure Options: Temperature controlled NEMA...
Open the catalog to page 7PROCESS ANALYZER GAIN REAL-TIME INSIGHT INTO YOUR PROCESS Process Insights manufactures and delivers premium sensors, monitors, detectors, analyzers, instrumentation, and software that are mission-critical to keep your operations, personnel, and the environment safe – every day across the globe. Get the most reliable, precision analytical technologies available on the market today. We will work to match your needs and budget, and provide the optimal, and most stable process analysis solution for your application. CENTERS OF EXCELLENCE | PROVIDING PROVEN SOLUTIONS Process Insights is...
Open the catalog to page 8All Process Insights catalogs and technical brochures
-
HALO Max QCL™
4 Pages
-
QuickTOCultra™
8 Pages
-
innovative water solutions
24 Pages
-
SERIES 2000
5 Pages
-
QuickTONultra
4 Pages
-
573 Dew Point Mirror™
8 Pages
-
T12
4 Pages
-
SERIES 3520™
4 Pages
-
SERIES 3500™ & 3510™
4 Pages
-
SERIES 3000™
4 Pages
-
SERIES 2520™
4 Pages
-
SERIES 2500™ & 2510™
4 Pages
-
ZRO 2000™
4 Pages
-
OXY-SEN™
4 Pages
-
SERIES 1300™
4 Pages
-
PCM 5000™
2 Pages
-
PCM 1000™
4 Pages
-
EVM™
4 Pages
-
Diamond 20™
4 Pages
-
Diamond MX™
4 Pages
-
Hydrocarbon SmartSystem
8 Pages
-
RefinIR™
4 Pages
-
RovIR™
4 Pages
-
Fiber Optic Cable
4 Pages
-
Turbidity Process Flow Cell
4 Pages
-
Teflon Process Flow Cell
4 Pages
-
Gas Process Flow Cell
4 Pages
-
Axial Process Flow Cell
4 Pages
-
G-SST™
4 Pages
-
RTD-SST
4 Pages
-
O-SST
4 Pages
-
SST
4 Pages
-
ClearView
4 Pages
-
LAB 508 UV-VIS
8 Pages
-
LAB NIR-O
8 Pages
-
NIR-O™ PROCESS ANALYZER
8 Pages
-
QuickTOCtrace™
8 Pages
-
QuickTOCuv™
4 Pages
-
QuickCODlab™
8 Pages
-
ToxAlarm™
4 Pages
-
NitriTox™
4 Pages
-
QuickTOCeco™
4 Pages
-
QuickTOCultra™
4 Pages
-
QuickTOCairport™
6 Pages
-
RGA
6 Pages
-
MB
8 Pages
-
HRQ
6 Pages
-
APIMS
2 Pages
-
MAX-QMS
2 Pages
-
MAX300-EGA
8 Pages
-
MAX300-LG
4 Pages
-
MAX300-CAT
4 Pages
-
MAX300-BIO
8 Pages
-
MAX300-AIR
8 Pages
-
MAX300-RTG™ 2.0
8 Pages
-
MODEL ESS-SCVP™
8 Pages
-
HDT
8 Pages
-
XDT
8 Pages
-
XPDM
8 Pages
-
LPDT2
4 Pages
-
Spark H2 O in CO2
6 Pages
-
HALO KA H2O
3 Pages
-
HALO OK
8 Pages
-
HALO H2O in N2O
2 Pages
-
HALO H2
4 Pages
-
HALO 3 NH3
3 Pages
-
HALO 3 HCI
3 Pages
-
HALO 3 CH4
3 Pages
-
HALO 3 H2O
4 Pages
-
HALO 3 D2O/HDO
4 Pages
-
HALO 3 CO2
4 Pages
-
HALO 3 CO
2 Pages
-
HALO 3 CH2O
2 Pages
-
HALO KA Max
4 Pages
-
VeraSpec™ APIMS
2 Pages
-
973
8 Pages
-
573
8 Pages
-
473 Dew Point Hygrometer
8 Pages
-
Zircomat
8 Pages
-
9610
8 Pages
-
9800 Calorimeter
4 Pages
-
Flare Gas Analyzers
1 Pages
-
MAX300-LG
8 Pages
-
MAX300-RTG 2.0
8 Pages