101-201210-1

COMbricks - SCOPE Repeater Technical Data Technical Data - SCOPE Repeater (101-201210) Technical Data - SCOPE Repeater (101-201210) Dimensions and weight Dimensions L x W x H Weight Mounting DIN-rail type 137 x 25 x 103 mm (including backplane, per module) 120 g (excluding plug-able connectors, backplane and packing material) 35mm x 7.5mm (EN 50022, BS 5584, DIN 46277-3) Ambient conditions Ambient operating temperature range Isolating class -20o ... +60o Celsius (for mounting position see manual) -4o... 158o Fahrenheit IP 20 (IEC/EN 60529, DIN 40050) PROFIBUS networks Modules Power supply Typical backplane current consumption Max. backplane current consumption Compatible backplane units 4 (set by dipswitches or web server) 10 (positioned in the first 10 slots) Provided through the backplane 400 mA (at 5.72 VDC) 600 mA (at 5.72 VDC) At this current consumption the module is switched OFF from backplane. Occurs when module is faulty, e.g. internal short circuit. 101-200011, 101-200022, 101-200023, 101-200024, 101-200027 Protocol specifications Supported Protocols Address Transmission speed Transmission speed detection Data delay time DP-V0, DP- V1, DP-V2, FDL, MPI, FMS, PROFIsafe, PROFIdrive and any other FDL based protocol NO bus address required 9.6 kbps .. 12 Mbps (including 45.45 kbps) Auto detect (< 10 s detection and 50 s baudrate switchover time) ComBricks-TechData-SCOPE-Rep-T1-V1.2.0-EN © PROCENTEC 2019 - Copyright - all rights reserved

 Open the catalog to page 1
101-201210-2

COMbricks - SCOPE Repeater Technical Data Technical Data - SCOPE Repeater (101-201210) Frequency Resolution Differential range PROFIBUS cable specifications Cable lengths Wire diameter (for the screw terminals) Wire type Number of devices Termination Redundancy Cascading depth Cascading units 1200 m at 9.6 kbps to 93.75 kbps 1000 m at 187.5 kbps 400 m at 500 kbps 200 m at 1.5 Mbps 100 m at 3 Mbps to 12 Mbps < 2.5 mm2 Stranded or solid core Maximum 31 devices per channel (busload) Integrated and switchable Powered according to PB RS 485 (390/220/390 Ohms) Yes, maximum 10 cables activated by switch No...

 Open the catalog to page 2
101-201210-3

COMbricks – SCOPE Repeater Technical Data Technical Data - SCOPE Repeater (101-201210) Connector Lay-out PROFIBUS screw terminal CH1 Plug-able screw terminal, pitch 5,08 mm Pin A: PROFIBUS A (green wire) Pin B: PROFIBUS B (red wire) Pin SH: Shield Pin I: Indirect Shield D Sub connector, 9 contacts (PROFIBUS specification) Pin 1: N.C. Pin 2: N.C. Pin 3: PROFIBUS - B Pin 4: PROFIBUS - RTS Pin 5: GND Pin 6: VPP Pin 7: N.C. Pin 8: PROFIBUS - A Pin 9: N.C. Housing: Shield Pin SH is connected internally to the DIN-rail with springloaded contact. Pin I is connected internally with 10nF/1MOhm to shield....

 Open the catalog to page 3
101-201210-4

COMbricks – SCOPE Repeater Technical Data Technical Data - SCOPE Repeater (101-201210) NW0 LEFT RIGHT LEFT RIGHT NW1 LEFT LEFT RIGHT RIGHT PROFIBUS Network Repeater Module 1 status 2 Data received 3 4 Communication error or bad telegrams Repeater internal failure Settings Hardware / Software Signal amplitude of the telegrams is too low The idle voltage when nobody is sending is too low Dipswitches or web server settings Network 1: NW0 = L, NW1 = L Network 2: NW0 = R, NW1 = L Network 3: NW0 = L, NW1 = R Network 4: NW0 = R, NW1 = R Redundancy for the current network EMC Directive 2014/30/EU, class...

 Open the catalog to page 4