Product data sheet DPS3

Product data sheet DPS3

Product data sheet DPS3

Product catalog summary
Overview
The DPS3 Heated Dew Point System is a hygrometer designed to measure dew points ranging from -35°C (-31°F) to 95°C (203°F). It features a microprocessor-based electronics system, a chilled mirror dew point sensor, and a heated sample line, all housed in a temperature-controlled NEMA-4 enclosure.

Applications
  • Fuel Cell Testing
  • Industrial Processes
  • Furnace Operations

Specifications
  • Heated Sensor Temperature Range: 20 to 99°C (68 to 210°F)
  • Dew Point Measurement Range: -35 to 95°C (-31 to 203°F)
  • Measurement Accuracy: ±0.2°C (±0.4°F)
  • Microprocessor Controlled with Display for Dew Point, Set Point, and Actual Temperature
  • User Programmable Temperature Controller
  • Automatic Balance Control
  • Integral Adjustable Flowmeter
  • Two Alarm Relays
  • Analog Outputs: Selectable 4 to 20mA, 0 to 5VDC, or 0 to 10 VDC
  • RS232 Output
  • Sample Connection: ¼ inch Compression Fitting
  • Sample Pressure: Up to 150psig
  • 3-foot Heated Hose Included
  • AC Power: 100 to 240VAC, 50/60Hz, 250 Watts

Options
  • Mirror Material: Standard Chrome or Optional Platinum
  • Pressure Rating: 200psi
  • Sample Flow: 0.5 to 5.0 SCFH (0.25 to 2.5 L/min)
  • Repeatability: ±0.05°C (0.9°F)

Physical Characteristics
  • Dimensions: 14 x 12 x 11 inches (35.6 x 30.5 x 28 cm)
  • Weight: 27 lbs (14.5 kg)
  • Mounting: Wall Mounted NEMA 4 Enclosure
See more

Catalog excerpts

Product data sheet DPS3-1

► Fuel Cell Testing Model DPS3 is a heated dew point hygrometer that can measure dew points up to 95°C (203°F) and as low as -35°C (-31°F). This integrated system includes a microprocessor based electronics, a chilled mirror dew point sensor, a sample flow meter/valve, a 3 foot heated sample line, assorted tubing and fittings; all contained in a heated, temperature controlled NEMA-4 enclosure. The heated sensor allows the measurement of high dew points that are above ambient temperature. Without the heated system condensation would occur and measurements could not be taken. The two-stage chilled mirror dew point sensor in the DPS3 provides an accurate and fundamental measurement of the dew point of the sample gas.

 Open the catalog to page 1
Product data sheet DPS3-2

► Heated Sensor Temperature Range: 20 to 99°C (68 to 210°F) ► Dew Point Measurement Range: -35 to 95°C (-31 to 203°F) ► Dew Point, Set Point Temperature and Actual Temperature Displays ► User Programmable Temperature Controller ► Automatic Balance Control ► Integral Adjustable Flowmeter ► Two Available Alarm Relays ► Selectable 4 to 20mA, 0 to 5VDC or 0 to 10 VDC Analog Outputs ► Sample Connection: % inch Compression Fitting ► 3 foot Heated Hose Supplied Mirror Material Standard: Chrome Optional: Platinum Pressure Rating: 200psi Sample Flow: 0.5 to 5.0 SCFH (0.25 to 2.5 L/min) Repeatability:...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.