EdgeTech field-proven chilled mirror technology. One, two or three stage sensors available - integral or remote from controller. NIST traceable calibration certificate. Scrolling menu via front panel & RS232. Depression range choice of either 45, 65 or 95°C . (one, two or three-stage cooling) Automatic Balance Control (ABC) o Automatically corrects for most mirror contaminants. o Automatically restandardizes the instrument. o You choose time and interval of restandardization, for best convenience. o Increase the length of unattended operation. Dual alarm capability o User programmable. o Can be set for latching or auto-reset mode. o Form C for greater versatility. Serial and analog outputs. RS232 communication with terminal, printer, or computer o Remote programming. o Data output such as dew point and alarm status. 0-5 VDC, 4-20 mA, 0-10 VDC, or 0-20mA o User scalable to drive peripheral devices. o Available simultaneously, one output per measurement parameter. o Scalable throughout the entire operating range of psychrometric variables. o Program via front panel or remote serial port. Pressure transducer input for psychrometric variable. Applications EdgeTech field proven technology Capable of measuring dew point, absolute pressure, PPMv and other psychrometric variables Primary chilled mirror measurement of water vapor content in gas Wide measuring range (-75 to 100°C) Automatic correction for mirror contaminants Certified measurements against NIST traceable standards Standard features, where others charge extra Analog & RS232 outputs Pro-Chem Analytik GmbH & Co.KG Neuer Bruchweg 1, 46509 Xanten Tel.: 02801/ 98510-70 Fax: 02801/ 98510-71 e-mail: [email protected] www.prochem-online.com Annealing Furnaces Process Dryers Clean Rooms Curing Ovens Plant Air Environmental Chambers Lab Calibration Standards Emission Testing Metrolo
Open the catalog to page 1Functional Power Requirements 90-230 VAC ±10%, 50-400Hz Auxiliary Coolant Water (or other) - 2 liters/minute (0.5 gallon/minute) at 100 psia maximum, to augment depression capability of sensor when necessary. Operating Temperature Control Unit: -10 to 60°C (15 to 140°F). DP Sensors: -40 to 100°C (-40 to 212°F). Sample Pressure 0 to 20 bar (0 to 300 psia), S1, S2 and S3. Depression Slew Rate 1.7°C (3°F)/Second Maximum, above 0°C Sample Flow Rate 0.25 to 2.4 liters/minute (0.5/5.0 SCFH). Remote Sensors Up to 75 meters (250 feet) Outputs (3 outputs available) 4-20 mA, 0-5 VDC, RS232. Resolution...
Open the catalog to page 22 Pages
2 Pages