Overview: This document provides comprehensive details on Mineral Insulated Resistance Temperature Detectors (RTDs) and their assemblies, focusing on their construction, calibration, and applications in temperature measurement.
Specifications:
  • RTDs are available in single or duplex configurations with elements like 1Pt100 or 2Pt100.
  • Sheath diameters range from 3.2 mm to 10 mm, using materials such as SS316.
  • Insulation is made of compact MgO with over 99% purity.
  • Calibration adheres to IEC 751 standards, offering Class A or B accuracy.
  • Configurations include two, three, or four-wire systems.
  • Protection ratings include IP-67 weatherproof and various flameproof certifications.
Features:
  • High integrity construction with laser welding for enhanced durability.
  • Operating temperature range from -200°C to 800°C.
  • Fast response time and high insulation resistance.
  • Mineral insulated construction allows bending without performance loss.
Advantages of Nickel Conductor RTDs:
  • Nickel conductors offer higher temperature stability and strength compared to copper.
  • Welded connections reduce the risk of loose connections and enhance durability under vibration.
  • Nickel's resistance to oxidation ensures stable readings over time.
Special Assemblies:
  • Includes skin temperature RTDs, multipoint RTD assemblies, and bearing temperature measurement RTDs.
  • Special designs for retractable telescopic assemblies and room temperature measuring RTDs.
Ordering Information:
  • Model numbers specify element type, sheath material, and configuration details.
  • Options include adjustable fittings, special error limits, and thermowell integration.
Temperature Transmitters:
  • RTD and thermocouple transmitters convert resistance or millivolt signals to 4-20mA current signals.
  • Transmitters are head-mounted and offer features like loop-powered operation and high accuracy.
Conclusion: The document emphasizes the precision and reliability of RTDs for industrial temperature measurement, focusing on customization and compliance with international standards.
Standard PT100 Industrial Design Specifications:
  • Nominal resistance of 100 ohms at 0°C using a four-wire system.
  • Temperature coefficient of 0.00385 ohms/ohm/°C, with a range from -200°C to 500°C.
  • Maximum cable temperature of 150°C, with resistance stability of ±0.20°C at 0°C after 1000 hours at 400°C.
  • Sheath material is Inconel 600, with Teflon™-insulated, silver-plated stranded copper leads.
  • Termination via four gold-plated spade lugs, with other options available.
  • Hysteresis is 0.04% maximum between -200°C and 500°C.
  • Time constant is four seconds maximum for a 63.2% response to a step change in water moving at 1 mps.
  • Calibration includes a National Physical Laboratory Certificate with specific calibration points.
  • Minimal immersion effects, with readings not varying more than 0.02°C in an ice bath.
  • Available sizes are PIR01-300 and PIR01-500.
Procedures and Tests:
  • Includes calibration as per IEC 751/DIN 43760 Class A & B, insulation resistance tests, sheath integrity tests, response time tests, self-heating error tests, radiography, and cryogenic temperature calibration.
  • Special tests include an autoclave test.
Accessories:
  • Includes connectors, wire clamp brackets, crimp bushings, and grommets suitable for thermocouple and RTD.
  • Connectors are made from thermoplastic compounds, with operating temperatures up to 250°C.
  • Crimp bushings are made from brass, available in various diameters.
  • Grommets prevent moisture and dust from entering connectors, made from neoprene.
Thermocouple Connectors:
  • Details on standard thermocouple connectors, including types and color codes according to ANSI and IEC standards.
  • Types include J, K, T, S, R, and U, with specific material compositions for each type.
See more

Catalog excerpts

RTD Complet-1

Ml THERMOCOUPLE CABLES & PROBES RESISTANCE TEMPERATURE DETECTORS (RTDs) TEMPERATURE TRANSMITTERS FIELD MOUNTED DIGITAL INDICATERS SKIN TYPE THERMOCOUPLE/ RTD ASSEMBLY MULTIPOINT THERMOCOUPLE/ RTD ASSEMBLY

 Open the catalog to page 1
RTD Complet-2

PRISMA Instruments & Gauge .Bourdon France RTDs Accurate temperature monitoring with a properly designed senso Temperature Detector used and control begins RTD - Resistance fo r te m p e ra tu re request), must have the physical configuration necessary for optimum thermal response to the process fluid it is sensing and the resistive element compatible with instrumentation. The system accuracy begins with proper primary sensor selection. The integrity of any temperature measuring device depends upon proper traceability. Our fully equipped measurement and testing laboratory maintains primary reference...

 Open the catalog to page 2
RTD Complet-3

RTDs PRISMA Instruments & Gauge J3ourdon France Specifications Element Element OD Sheath material Insulation Calibration Conductor Configuration Open end Head Protection Extension Optional Routine tests : 1Pt 100 or 2 Pt 100 - single or duplex (triplex on request) with leadout MI cable of 2.8 mm, 5 mm respectively Straight construction with continuous OD of 6 mm , 8 mm, 10 mm also available. SS316 Mi neral, compact MgO ( over 99% purity) In accordance with IEC-751 / DIN 43760 (class B or A) Copper (Nickel on request*) Two wire, three wire or four wire Pot seal or quick connect-disconnect plug...

 Open the catalog to page 3
RTD Complet-4

PRISMA Instruments & Gauge .Bourdon France In continuation with its endeavour to provide products of best quality to clients, we have developed RTD with Nickel conductor in Mineral Insulated Construction for the first time in India. The basic difference between the conventional & Nickel conductor is material of conductor. In conventional, it is inst Nickel in newly developed MI. 1. Most important advantage is that the RTD element is welded on to conductors and not brazed. As such same RTD can be used for much higher temperature of up to 6000C . In conventional RTD with copper conductor, brazing...

 Open the catalog to page 4
RTD Complet-5

Mineral Insulated RTDs Special Assemblies Skin temperature RTDs: Combines a precision element with low cost, easily installable accessories and flexible thermal cable with an ability to produce fast response surface sensing. Bearing temperature measurement RTDs : Miniature detector for embedment in thrust pads-spring loaded holder with fluid seal easily adjustable for a proper loading at any hole depth. These are installed in babbit layer of large bearing for immediate warning of possible failure. Room temperature measuring RTDs: RTD assemblies with a suitable protecting tube and surface mounted...

 Open the catalog to page 5
RTD Complet-6

Mineral Insulated RTDs Special Bearing Type RTD Assembly Hygiene Assembly RTD Assembly with plug and jack connector

 Open the catalog to page 6
RTD Complet-7

Mineral Insulated RTDs How to Order TYPE : RTD-I-TB TYPE : RTD-I-PJ OPTION / SPECIAL 1. Adjustable compression fitting in SS316 (specify the size) 2. Spring loaded bayonet fitting 3. Lugs for tails 4. Special limits of error 5. Calibration standard (specify other than IEC-751) 6. Triplex element 7. Bulk Head Connector 8. Thermowell 0. None EXTENSION CABLE LENGTH (L2) Specify in mtr EXTENSION CABLE TYPE 1. PTFE insulated tails-55mm long 2. PTFE insulated, PTFE overall cable 3. PTFE insulated, overall PTFE & SS braided cable Standard Features : a - Mineral insulated (compact MgO) construction b...

 Open the catalog to page 7
RTD Complet-8

Instruments IVlin era I Insulated RTD & Gauge .Bourdon France TYPE : RTD H - A TYPE : RTD H - C OPTION / SPECIAL 1. Cable gland (specify material) 2. Two cable entries 3. Head mounted transmitter 4. Plug for cable entry (specify material) 5. Connection(other than specified) 6. FG/FG, SS braided cable (specify length e.g. 6(3) i.e. 3 Mtr cable) 7. Sp ecial limits of error 8. Thermowell 0. None Ex Specify in mm CONNECTION MATERIAL C - Cd plated CS S4 - SS304 S6 - SS316 HEAD WAL : Aluminium (LM6 Gr.), Weatherproof (IP-66) WS4 : SS304, Weatherproof (IP-66) WS6 : SS316, Weatherproof (IP-66) FLAL :...

 Open the catalog to page 8
RTD Complet-9

& Gauge bourdon France (Suitable for Temperature Transmitter) We have the capability of supplying temperature Element (T/c as well as RTD) assemblies suita ble for temperature transmitters. Th e transmitter either can be mounted in the enclosure (Head) or connected to the extension (in the form of Nipple-union-nipple) that comes with built in enclosure. (with or without indication) The assemblies are offered complete with element, head & thermowell. In either case, the spring loading is provided ensures proper contact of the element to the bottom of thermowell. Moreover the assembly (if the transmitter...

 Open the catalog to page 9
RTD Complet-10

PRISMA Instruments & Gauge .Pourdon France Indication Features Battery or mains operated. Special magnetic key for battery operated model to save battery consumption. Combination of local indication with provision for parallel remote indication We atherproof or flameproof case. Longer length of sensor available. Accuracy better than 1% full scale. Specifications Display Resolution Range ower supply Process connecting Mounting Accessory RTD or thermocouple, single or duplex a) SS304 for battery operated b) Diecast Alu^iniu^ (LM6 G r.) for mains operated a) Weatherproof to IP - 67 (IS - 13947 Part...

 Open the catalog to page 10
RTD Complet-11

RTD temperature transmitters convert the RTD resistance measurement to a current signal, eliminating the problems inherent in RTD signal transmission via lead resistance. Errors in RTD circuits (especially two and three wire RTDs) are often caused by the added resistance of the lead wire between the sensor and the instrument. Transmitter input, specifications, user interfaces, features, sensor connections, and environment are all important parameters to consider when searching for RTD temperature transmitters. Trans mitter input specifications to take into consideration when selecting RTD temperature...

 Open the catalog to page 11
RTD Complet-12

Precision Industrial RTDs Any industrial installation has several electrical thermometers such as Thermocouples & RTDs. At a regular interval, these instruments are required to be checked against a ‘Standard Industrial RTD’, which has accuracy to the level of 1/10th DIN. with its vast experience in design and manufacturing of precision instruments has developed ‘Standard PT100 Industrial RTD’ which caters to such requirements of client. These RTDs are traceable to National Physical Laboratory (NPL) and are either provided with Original Calibration Certificate from NPL with very low level of uncertainty...

 Open the catalog to page 12

All Prisma Instruments catalogs and technical brochures

  1. DUS-TT-CE

    4  Pages

  2. DUS-TT-FC

    5  Pages

  3. MODEL : APG

    2  Pages

  4. DUS-TT-F Gold

    3  Pages

  5. Additel 761

    5  Pages

  6. DUS-TT-PC

    4  Pages

  7. ADT-680

    2  Pages

  8. DPG-B

    2  Pages

  9. SFBSPG

    2  Pages

  10. TNRP51

    29  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.