Ml THERMOCOUPLE CABLES & PROBES RESISTANCE TEMPERATURE DETECTORS (RTDs) TEMPERATURE TRANSMITTERS FIELD MOUNTED DIGITAL INDICATERS SKIN TYPE THERMOCOUPLE/ RTD ASSEMBLY MULTIPOINT THERMOCOUPLE/ RTD ASSEMBLY

Open the catalog to page 1
RTD Complet - 2

PRISMA Instruments & Gauge .Bourdon France RTDs Accurate temperature monitoring with a properly designed senso Temperature Detector used and control begins RTD - Resistance fo r te m p e ra tu re request), must have the physical configuration necessary for optimum thermal response to the process fluid it is sensing and the resistive element compatible with instrumentation. The system accuracy begins with proper primary sensor selection. The integrity of any temperature measuring device depends upon proper traceability. Our fully equipped measurement and testing laboratory maintains primary...

Open the catalog to page 2
RTD Complet - 3

RTDs PRISMA Instruments & Gauge J3ourdon France Specifications Element Element OD Sheath material Insulation Calibration Conductor Configuration Open end Head Protection Extension Optional Routine tests : 1Pt 100 or 2 Pt 100 - single or duplex (triplex on request) with leadout MI cable of 2.8 mm, 5 mm respectively Straight construction with continuous OD of 6 mm , 8 mm, 10 mm also available. SS316 Mi neral, compact MgO ( over 99% purity) In accordance with IEC-751 / DIN 43760 (class B or A) Copper (Nickel on request*) Two wire, three wire or four wire Pot seal or quick connect-disconnect...

Open the catalog to page 3
RTD Complet - 4

PRISMA Instruments & Gauge .Bourdon France In continuation with its endeavour to provide products of best quality to clients, we have developed RTD with Nickel conductor in Mineral Insulated Construction for the first time in India. The basic difference between the conventional & Nickel conductor is material of conductor. In conventional, it is inst Nickel in newly developed MI. 1. Most important advantage is that the RTD element is welded on to conductors and not brazed. As such same RTD can be used for much higher temperature of up to 6000C . In conventional RTD with copper conductor,...

Open the catalog to page 4
RTD Complet - 5

Mineral Insulated RTDs Special Assemblies Skin temperature RTDs: Combines a precision element with low cost, easily installable accessories and flexible thermal cable with an ability to produce fast response surface sensing. Bearing temperature measurement RTDs : Miniature detector for embedment in thrust pads-spring loaded holder with fluid seal easily adjustable for a proper loading at any hole depth. These are installed in babbit layer of large bearing for immediate warning of possible failure. Room temperature measuring RTDs: RTD assemblies with a suitable protecting tube and surface...

Open the catalog to page 5
RTD Complet - 6

Mineral Insulated RTDs Special Bearing Type RTD Assembly Hygiene Assembly RTD Assembly with plug and jack connector

Open the catalog to page 6
RTD Complet - 7

Mineral Insulated RTDs How to Order TYPE : RTD-I-TB TYPE : RTD-I-PJ OPTION / SPECIAL 1. Adjustable compression fitting in SS316 (specify the size) 2. Spring loaded bayonet fitting 3. Lugs for tails 4. Special limits of error 5. Calibration standard (specify other than IEC-751) 6. Triplex element 7. Bulk Head Connector 8. Thermowell 0. None EXTENSION CABLE LENGTH (L2) Specify in mtr EXTENSION CABLE TYPE 1. PTFE insulated tails-55mm long 2. PTFE insulated, PTFE overall cable 3. PTFE insulated, overall PTFE & SS braided cable Standard Features : a - Mineral insulated (compact MgO) construction...

Open the catalog to page 7
RTD Complet - 8

Instruments IVlin era I Insulated RTD & Gauge .Bourdon France TYPE : RTD H - A TYPE : RTD H - C OPTION / SPECIAL 1. Cable gland (specify material) 2. Two cable entries 3. Head mounted transmitter 4. Plug for cable entry (specify material) 5. Connection(other than specified) 6. FG/FG, SS braided cable (specify length e.g. 6(3) i.e. 3 Mtr cable) 7. Sp ecial limits of error 8. Thermowell 0. None Ex Specify in mm CONNECTION MATERIAL C - Cd plated CS S4 - SS304 S6 - SS316 HEAD WAL : Aluminium (LM6 Gr.), Weatherproof (IP-66) WS4 : SS304, Weatherproof (IP-66) WS6 : SS316, Weatherproof (IP-66) FLAL...

Open the catalog to page 8
RTD Complet - 9

& Gauge bourdon France (Suitable for Temperature Transmitter) We have the capability of supplying temperature Element (T/c as well as RTD) assemblies suita ble for temperature transmitters. Th e transmitter either can be mounted in the enclosure (Head) or connected to the extension (in the form of Nipple-union-nipple) that comes with built in enclosure. (with or without indication) The assemblies are offered complete with element, head & thermowell. In either case, the spring loading is provided ensures proper contact of the element to the bottom of thermowell. Moreover the assembly (if the...

Open the catalog to page 9
RTD Complet - 10

PRISMA Instruments & Gauge .Pourdon France Indication Features Battery or mains operated. Special magnetic key for battery operated model to save battery consumption. Combination of local indication with provision for parallel remote indication We atherproof or flameproof case. Longer length of sensor available. Accuracy better than 1% full scale. Specifications Display Resolution Range ower supply Process connecting Mounting Accessory RTD or thermocouple, single or duplex a) SS304 for battery operated b) Diecast Alu^iniu^ (LM6 G r.) for mains operated a) Weatherproof to IP - 67 (IS - 13947...

Open the catalog to page 10
RTD Complet - 11

RTD temperature transmitters convert the RTD resistance measurement to a current signal, eliminating the problems inherent in RTD signal transmission via lead resistance. Errors in RTD circuits (especially two and three wire RTDs) are often caused by the added resistance of the lead wire between the sensor and the instrument. Transmitter input, specifications, user interfaces, features, sensor connections, and environment are all important parameters to consider when searching for RTD temperature transmitters. Trans mitter input specifications to take into consideration when selecting RTD...

Open the catalog to page 11
RTD Complet - 12

Precision Industrial RTDs Any industrial installation has several electrical thermometers such as Thermocouples & RTDs. At a regular interval, these instruments are required to be checked against a ‘Standard Industrial RTD’, which has accuracy to the level of 1/10th DIN. with its vast experience in design and manufacturing of precision instruments has developed ‘Standard PT100 Industrial RTD’ which caters to such requirements of client. These RTDs are traceable to National Physical Laboratory (NPL) and are either provided with Original Calibration Certificate from NPL with very low level of...

Open the catalog to page 12

All Prisma Instruments catalogs and technical brochures

  1. DUS-TT-CE

    4 Pages

  2. MODEL : APG

    2 Pages

  3. Additel 761

    5 Pages

  4. DUS-TT-PC

    4 Pages

  5. ADT-680

    2 Pages

  6. DPG-B

    2 Pages

  7. SFBSPG

    2 Pages

  8. DUS-TT-FC

    5 Pages

  9. TNRP51

    29 Pages