Advanced Autoclave Control System TACTROL® 2 At the heart of every Priorclave is the highly successful TACTROL®2 microprocessor control system which has been specifically developed for laboratory autoclaves. From simple cycles to fully featured multi-program operation with printed records, this powerful controller allows unrivalled flexibility and monitoring. By fully automating the sterilising process and with features to assist with autoclave management, TACTROL®2 allows you to continue with other tasks secure in the knowledge that autoclaving is proceeding safely and efficiently. TACTROL®2 offers simple and variable settings of process time and temperature and graphic indication of cycle status. Just set the temperature and time required, select any options needed and press start, operation is fully automatic once the cycle has started. A tough, clear control panel with digital displays continuously provides information on status. A full log of autoclave activity is held in the system and can be downloaded for diagnostic or monitoring purposes. Priorclaves also come fitted with a Pressure Gauge, Thermostatic Air Purge Valve, Low Water Cut Out, Electrically Operated Vent Valve, Automatic Timed Freesteaming and two Thermocouple Entry Ports. Packed with self-monitoring systems,TACTROL®2 has pre-set actions for events such as power failure or low water levels. A number of features are built in allowing cycle optimisation for the diverse functions demanded by the modern laboratory. Control options are available for every autoclaving need. To prevent unauthorised access to the control panel a security setting lock is available. multi-program memory (optional) load sensed process timing automatic freesteaming STARr 'clave accelerated cooling vacuum (optional) media wamrng
Open the catalog to page 1CONTROL FEATURES at A GLANCE Automatic Freesteaming A venting period during heating, which greatly improves temperature distribution by encouraging air removal. Also available - Pulsed Freesteaming - for improved waste load performance. Load Sensed Process Timing An internal probe placed in the anticipated coolest part of the load gives guaranteed sterilisation times. If a printer is fitted load temperature is included on the printed record. Accelerated Cooling Powerful fans blow cold air over the autoclave vessel reducing cooling times to safe load temperatures. A delayed start can be set...
Open the catalog to page 2All Priorclave catalogs and technical brochures
-
z - Knowledge Bank
38 Pages
-
Top Loading 100 150 & 200L
2 Pages
-
Priorclave Autoclave
16 Pages
-
Pass Through Priorclave
1 Pages
-
Autoclave Consumables
2 Pages
-
Top Loading 100L Priorclave
2 Pages
-
60L Compact Priorclave
2 Pages
-
ZQ63 Promo Sheet
1 Pages
-
ZQCSH Promo Sheet
1 Pages
-
Laboratory Autoclaves
16 Pages
-
230L RSC Priorclave
2 Pages
-
Benchtop 40L Priorclave
2 Pages
-
Power Door Priorclave
2 Pages
-
Front Loading Autoclaves
2 Pages
-
Compact Benchtop Autoclave
2 Pages
Archived catalogs
-
Priorclave Service Brochure
4 Pages
-
Priorclave Autoclave Consumables
3 Pages
-
New Opal Range
2 Pages
-
Jacketed Priorclaves
1 Pages
-
Double Door Priorclave Datasheet
2 Pages
-
Easy Autoclave Cleaning
1 Pages
-
Priorclave Product Brochure
8 Pages