Calibration Overview
Calibration is the process of determining the actual temperature inside an autoclave when a specific temperature is set. This is crucial because without calibration, the actual temperature remains unknown, which could lead to improper sterilization. Calibration, especially when performed by a UKAS accredited laboratory, demonstrates due diligence and reasonable care.

Calibration Process
A calibration engineer inserts a calibrated probe into the autoclave, runs it at a set temperature, and takes readings to produce a calibration certificate. The procedures vary by company but adhere to approved standards. Calibration may not include adjustment of controls due to software access restrictions. If adjustment is not possible, the set temperature can be adjusted based on the calibration certificate data.

Cost Considerations
The cost of calibration often includes travel expenses for the engineer. Choosing a local, UKAS accredited calibration company can be cost-effective. Calibration can also be part of routine service visits.

Performance Qualification
This testing ensures the autoclave and its load are properly processed. A calibrated data logger measures multiple points in the load and autoclave. Performance qualification identifies setup issues and is essential for understanding load processing. It is crucial that test loads reflect actual processing loads.

Understanding Uncertainties
All measurements have errors, categorized as known errors and uncertainties. Calibration certificates indicate results with uncertainty and confidence levels. For example, a 95% confidence level means there is a 95% probability that the true temperature is within the stated range. Increasing confidence levels increases uncertainty limits.

Contact Information
For further details, contact Mr. Peter Melling, Quality and Calibration Manager at Priorclave Ltd., London, England. Tel: +44 (0) 208 316 6620, Fax: +44 (0) 208 855 0616, www.priorclave.co.uk, Email: [email protected]
See more

Catalog excerpts

Calibration and Performance Testing of Autoclaves-1

Calibration and Performance Qualification Testing of Autoclaves.doc10/07/2006 What is calibration? Calibration is the process of determining the actual*temperature inside an autoclave when a given temperature is set.* Where actualђ means best estimateђ. See Uncertaintiesexplainedђbelow. So why bother? Well, without a calibration even with its uncertainties, the actual temperature inside theautoclave is unknown. The electronics may be wrong, the temperature probe may be damaged, the pressure gauge ֖ a very useful backup - may also be wrong etc. - Is it worth the risk if the process is not sterilising properly? - Is it worth the risk, in this litigious world, if the autoclave is not covered by a calibration?Calibrating, particularly if a UKAS* calibration laboratory is employed provides a powerfuldemonstration, in a court of law, that due diligence has been properly exercised. It showsthatall reasonable careђ has been taken. * UKAS is the United Kingdom Accreditation Service. They are the sole organisationrecognised by the UK government to assess calibration laboratories against international criteria.(go to www.ukas.org for more details.) What does it involve? The calibration engineer will insert a calibrated probe into an autoclave and run it at a settemperature, taking sufficient readings to produce a calibration certificate. The actualprocedures used will vary from company to company but all UKAS accredited calibrationlaboratories will work to approved procedures. The data is then used to produce a calibrationcertificate. The engineer may also attach seals to prevent access to areas that allow thecalibration to be altered. Adjustment. Calibration does not always include adjustment of the autoclave controls. Often themanufacturers control software is not accessible to untrained, third party engineers, forobvious reasons. If the autoclave cannot be adjusted and is significantly out, then the settemperature can be adjusted to compensate the difference by using the data on thecalibration certificate. If for any reason adjustment of an autoclave is not required the serviceengineer should be informed - preferably beforehand. What does it cost? This depends. The largest cost in the calibration is often getting the engineer to and from thesite. Once on site the work is generally straightforward, if rigorously controlled. It thereforemakes financial sense to choose a calibration company that has local engineers and is alsoUKAS accredited for the calibration. Calibration can also be performed as part of a routine service visit at agreed intervals. This is often an economical solution. Performance qualification. This is one of several generic terms for testing an autoclave - and its load - to ensure the loadis properly processed. Usually a calibrated, multi channel, data logger is employed for themeasurement so that considerable numbers of points in the load, together with salient pointson the autoclave, can be logged. Analysis of these results can point to many problems in thesetup of the autoclave or in the way the load is contained. Significant differences can be >

 Open the catalog to page 1
Calibration and Performance Testing of Autoclaves-2

Calibration and Performance Qualification Testing of Autoclaves.doc10/07/2006 seen, for instance, between glass and plastic bottles or plastic and metal discard containers,or between single and double bagged discard loads.Performance qualification is the only way to know what is actually happening to the load.It is vital that the test load is typical of loads actually processed as the results cannotnecessarily be read across. A good calibration laboratory will consider and discuss thesefactors with the customer prior to their engineer arriving. However, once the performance qualification is done,...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.