Overview: The document provides technical specifications for the Presco AG Automatic Current and Potential Transformer Test Set, Series W. It is designed for testing the ratio error and phase displacement of instrument transformers, offering a broad range of corrections and remote control capabilities via an RS232 interface.
Variants: The test set is available in three variants: WD-ST for both Current Transformers (CT) and Potential Transformers (PT), WI-ST for CT only, and WU-ST for PT only.
Technical Specifications:
Current Transformer Test Part:
  • Nominal currents: 5, 2, and 1 A
  • Standard CT nominal current: 5 A
  • Matching range: 0.5 to 1.6
  • Working range: 1 to 210% of nominal current
  • Frequency: 50 and 60 Hz
  • Measuring range ratio error: ± 20%
  • Resolution ratio error: 0.001%
  • Measuring range phase angle: ± 200 crad
  • Resolution phase angle: 0.001 Min or 10 µrad
  • Uncertainty of ratio measurement: ± 100 ppm ± 1% of reading
  • Uncertainty of phase measurement: ± 100 µrad ± 1% of reading
  • Inherent burden: N-Side < 20mΩ, X-Side 30mΩ/5A, 80 mΩ/2A, 200mΩ/1A
  • Resolution current measurement: 0.1% / 0.001A
  • Uncertainty current measurement: ± 1% reading ± 1% of range
Potential Transformer Test Part:
  • Nominal voltage: 30 to 350 V with factors 1, 1/2, 1/3, 1/√3
  • Standard PT nominal voltage: 30 to 350 V with factors 1, 1/2, 1/3, 1/√3
  • Matching range: 0.5 to 1.6
  • Working range: 1 to 210% of nominal current
  • Input voltage range: 1 V to 350 V
  • Frequency: 50 and 60 Hz
  • Measuring range ratio error: ± 20%
  • Resolution ratio error: 0.001%
  • Measuring range phase angle: ± 200 crad
  • Resolution phase angle: 0.001 Min or 10 µrad
  • Uncertainty of ratio measurement: ± 100 ppm ± 1% of reading
  • Uncertainty of phase measurement: ± 100 µrad ± 1% of reading
  • Inherent burden: 30 kΩ to 110 kΩ
  • Resolution voltage measurement: 0.1% / 0.01 kV
  • Uncertainty voltage measurement: ± 1% reading ± 1% of range
Reference Conditions:
  • Temperature: 23°C ± 2°C
  • Humidity: 45 to 75%
  • Air pressure: 101.3 kPa
Rated Range of Use:
  • Temperature: 5°C to 40°C
  • Humidity, not condensing: 10 to 90%
  • Air pressure: 70 to 106 kPa
Physical Specifications:
  • Dimensions: 449 x 446 x 177 mm (19” x 4U)
  • Weight: 15 kg
  • Power mains: 115/230V 50/60Hz 50VA
See more

Catalog excerpts

W Series - Automatic Current and Potential  Transformer Test-1

Automatic Current and Potential Transformer Test - Set Series - W Standard version • For testing of ratio error and phase displacement of instrument transformers • Broad range of corrections • Display of the results in all accepted dimensions • Remote control and data transfer via RS232 interface • Variants o WD-ST for CT and PT o WI-ST for CT o WU-ST for PT

 Open the catalog to page 1
W Series - Automatic Current and Potential  Transformer Test-2

Presco ag Technical Specifications Automatic Current and Potential Transformer Testing Instrument Type WD-ST00 Current Transformer test part Nominal currents of the CT to be tested (X) Nominal Current of the standard CT (N) Matching Working range Frequency Measuring range ratio error Resolution ratio error Measuring range phase angle Resolution phase angle Uncertainty of ratio measurement Uncertainty of phase measurement Inherent burden N-Side Inherent burden X-Side Resolution current measurement Uncertainty current measurement Potential Transformer test part Nominal voltage of the PT to be...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.