Specifications:
  • Maximum current through test object: 5 A (extendable to 20 A).
  • Maximum current through standard capacitor: 30 mA.
  • Capacitance measuring range: 0.1 × CN to 1,000 × CN (extendable to 10,000 × CN).
  • Dissipation factor range: 1×10-5 to 1.
  • Voltage measurement range: 10 V to 1 MV.
  • Frequency measurement range: 45 Hz to 65 Hz.
  • Uncertainty of capacitance measurement: ± 0.01%.
  • Uncertainty of phase measurement: ± 0.02 mrad ± 1% of the displayed value.
  • Uncertainty of voltage measurement: ± 1% of reading.
  • Uncertainty of frequency measurement: ± 1% of the displayed value.
Reference Conditions:
  • Minimal current through standard capacitor: 35 µA.
  • Temperature: 23°C ± 2°C.
  • Humidity: 45% to 75%.
  • Altitude (pressure): 101.3 kPa.
Rated Range of Use:
  • Temperature: 5°C to 40°C.
  • Humidity, non-condensing: 20% to 95%.
  • Altitude (pressure): 70 to 106 kPa.
Display: LCD-Graphics with dimensions 500 × 470 × 192 mm (w × d × h) and mass of 15 kg.
Power Supply: 230V / 50Hz / 25VA.
Optional Software: Data Processing & Recording Software TG-0MOD-CP01 compatible with Windows, offering data transfer via RS232, processing, displaying, printing, saving, and Excel transfer capabilities.
Contact Information: Presco AG, Zürcherstrasse 70, CH-8104 Weiningen, Switzerland. Phone: +41 44 750 63 63, Fax: +41 44 750 63 66, Email: [email protected], Website: www.prescoag.com.
Note: Specifications are subject to change.
See more

Catalog excerpts

TG – 3-1

• fully automatic capacitance and power factor measuring bridge • For high voltage insulation diagnostics • 1... 2 x 10-5 uncertainty and 10-6 resolution for dissipation factor measurement • measures impedances in all four quadrants • built-in RS232 interface • Option: Higher Cx - current range

 Open the catalog to page 1
TG – 3-2

maximal current through test object maximal current through standard capacitor capacitance measuring range dissipation factor range voltage measurement frequency measurement uncertainty of capacitance measurement uncertainty of phase measurement uncertainty of voltage measurement uncertainty of frequency measurement reference conditions minimal current through standard capacitor temperature humidity altitude (pressure) 5 A (with optional range extension up to 20 A) 30 mA 0.1 x CN ... 1'000xCN (with optional range extension up to 10'000 x CN) 1x10-5 ... 1 10 V ... 1 MV 45 Hz ... 65 Hz ± 0.01% ±...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.