TG – 1
1 /2Pages

TG – 1

TG – 1
1 /2Pages

Catalog excerpts

TG – 1-1

Capacitance and Dissipation Factor Measuring Bridge Type TG-1MOD • For high voltage insulations diagnostics • Allows precise measurements of capacitance and dissipation factor • Measures impedances in all four quadrants • Features classical balancing using analogue zero indicator and • Fully automatic balancing • Remote control and data transfer via RS232 interface • Options: higher Cx – current range

 Open the catalog to page 1
TG – 1-2

Capacitance and Dissipation Factor Measuring Bridge Maximal current through test object Maximal current through standard capacitor Capacitance measuring range Dissipation factor range Resolution dissipation factor Voltage measurement Uncertainty of capacitance measurement Uncertainty of phase measurement Uncertainty of voltage measurement Measurement frequency Interface 5 A (with range extension up to 20 A) 30 mA 0.1 x Cn ... 1 '000 x Cn (with range extension up to 10'000 x CN) 1 x 10-5 ... 1 10-5 (trough software 10-7) 10 V ... 1 MV ± 0.01 % ± 0.02 mrad ± 1 % of the displayed value ± 1 % of...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.