general catalogue
20Pages

{{requestButtons}}

Catalog excerpts

general catalogue - 2

GENERAL CATALOGUE 2018 LEGAL DISCLAIMER “All the information contained in this catalogue is for general guidance on any matters of interest. As such, it should not be used as a substitute for consultation with professional Premo technicians or competent advisers. Before making any decision or taking any action, you should consult a Premo professional for updated and detailed information.” “Given the changing nature of the electronic market, and the inherent hazards of publications and communication, there may be omissions or inaccuracies in the information contained in this catalogue....

Open the catalog to page 2
general catalogue - 3

GENERAL CATALOGUE CONTENTS01. RFID COMPONENTS | PAG 24 1.1 RFID TRANSPONDERS 1.1.1 SINGLE AXIS TRANSPONDERS INDUCTORS | PAG 26 1.1.2 3-AXES TRANSPONDER INDUCTORS | PAG 62 1.1.3 NFC ANTENNAS | PAG 106 1.2 EMITTER ANTENNAS 1.2.1 SHORT RANGE | PAG 128 1.2.2 MIDDLE RANGE | PAG 158 1.2.3 LONG RANGE | PAG 172 1.3 TELECOILS 2.1 Rx EM MOTION TRACKING SENSORS | PAG 199 2.2 Tx EM MOTION TRACKING ANTENNAS | PAG 212 04. INDUCTIVE COMPONENTS | pag 234 4.1 OBC TRANSFORMERS | PAG 238 4.2 DCDC TRANSFORMERS | PAG 242 4.3 3DPOWER | PAG 252 4.4 PFC CHOKES | PAG 262 4.5 HIGH-CURRENT DC CHOKE | PAG 270 4.6...

Open the catalog to page 3
general catalogue - 4

3DC12EM - SMD 3D Coil 12.9 x 12.5 x 3.65mm Epoxy Moulding PREMO GENERAL CATALOGUE 2018 GENERAL CATALOGUE 2018 PREMO

Open the catalog to page 4
general catalogue - 5

1.2.2 MIDDLE RANGE KGEA-MR - Middle Range Antenna LF for smart entry system KGEA-MRHB - Middle Range Antenna LF for smart entry system LFAD-MR - Middle Range Antenna LF for smart entry system 1.2.3 LONG RANGE ANTENNA KGEA-AF/AFC - Long Range Flexible Antenna LF for smart entry system KGEA-AFULR - Ultra Long Range Flexible Antenna LF for smart entry system 3. WIRELESS CHARGING ANTENNAS WC-TX-001-90K - Ground assembly flexible-pad for the wireless power transfer in the electric vehicles. IN WC-RX-002-90K - Vehicle assembly flexible-pad for the wireless power transfer in the electric 4.1 OBC...

Open the catalog to page 5
general catalogue - 6

4.6 COMMON MODE CHOKES CMCF2R0-16V - Common Mode Choke 2x2mH / 16Arms CMCF0R9-16V - Common Mode Choke 2x0.9mH / 16Adc CMCN1R0-36V - Common Mode Choke 2x1mH / 36Adc CMCN25R-16V - Common Mode Choke 2x25mH / 16Arms CMCN10R-16V - Common Mode Choke 2x10mH / 16Arms MICU 300A - Medium Voltage Inductive Coupling Units MICU 300A OH/LF - MV ICU 300A Low Freq.(30-500kHz) Outdoor Overhead MICU 300A-W/LF - MV ICU/Low Freq. (30-500kHz) Underground WR Immersion BF (PLC BLOCKING FILTERS-SINGLE PHASE) RINDLS6R3-30T - LLC Serial Resonant Inductor 6.3μH/30Apk 100-250kHz GDAU-001 - Isolated SMD Gate Drive...

Open the catalog to page 6
general catalogue - 9

INDUCTIVE COUPLERS INDUCTIVE COUPLERS Inductive coupler in MV/LV overhead transformer Inductive coupler in MV/LV substation

Open the catalog to page 9
general catalogue - 10

INDUCTIVE COUPLERS INDUCTIVE COUPLERS In smart grids inductive couplers are playing a big role as it's transmit the communication signals between powerline and PLC data transceiver without introducing any new wires or cables, being a competitive solution compared with capacitive coupling. PREMO medium voltage inductive coupler family (MICU 300A-S/LF/OH/W-LF) have been developed for installation in smart grids deployments that requires different Levels of isolation, in overhead medium voltage installation (>24kV), or inside cabinets of MV/LV substations (>4.7kV). These compacts and...

Open the catalog to page 10
general catalogue - 11

PLC COMPONENTS / INDUCTIVE COUPLERS ELECTRICAL SPECIFICATIONS Nominal current Rated Voltage Only depends on the insulation evel of the cable CHARACTERISTICS >> Inner diameter: 44mm >> Height: 90mm >> Height including ground connector: <115mm >> Connection to PLC-modern: female BCN connector >> Connection to Earth: M5 screw >> Typical installation time: 10 minutes >> Operating conditions: indoor services Rated AC withstand voltage Only depends on the insulation evel of the cable Rated lightning withstand voltage (1.2/50s) Only depends on the insulation evel of the cable Partial discharge...

Open the catalog to page 11
general catalogue - 12

Low Frequency (3D-5DDkHz)PLC COMPONENTS / INDUCTIVE COUPLERS 02 SPECIFICATIONS DIMENSIONS (mm) APPLICATIONS > AMR (Automatic Meter Recording) > Automation of Electric Power Distribution System > Outdoors Bare Overhead Power Lines > Tolerances unless specified: ±1,0mm > Critical dimensions (*) ELECTRICAL SPECIFICATIONS

Open the catalog to page 12
general catalogue - 13

Low Freq. (30-500kHz)PLC COMPONENTS / INDUCTIVE COUPLERS 02 SPECIFICATIONS DIMENSIONS (mm) APPLICATIONS > AMR (Automatic Meter Recording) > Automation of Electric Power Distribution System > Outdoors Bare Overhead Power Lines > Tolerances unless specified: ±1,0mm > Critical dimensions (*) ELECTRICAL SPECIFICATIONS 01 CHARACTERISTICS > High current solution made with high permeability high performance materials avoidsaturation problems at high currents > Low insertion losses 12dB±2dB (@100- 250kHz) ; 5dB±2dB (@250-600kHz) > More electrical safety: High insulation > 24 kV > Compact equipment:...

Open the catalog to page 13
general catalogue - 14

MV ICU / Low Freq. (30-500kHz) Underground WR Immersion PLC COMPONENTS / INDUCTIVE COUPLERS 02 SPECIFICATIONS APPLICATIONS > Automatic Metering Reading > Powerline Monitoring Systems > Automation of Electric Power Distribution > Overhead Powerlines > Tolerances unless specified: ±1,0mm > Critical dimensions (*) ELECTRICAL SPECIFICATIONS CENELEC B (95-125kHz) CENELEC C (125-140kHz) CENELEC D (140-148.5kHz) USA FCC (10kHz-490kHz) CHARACTERISTICS > High current solution made with high permeability high performance materials avoid saturation problems at high currents > Low insertion losses...

Open the catalog to page 14
general catalogue - 16

Nowadays energy distribution grids are becoming more complex systems. A reliable and efficient management of these systems involve a deep managing and control of the power grid elements (software and hardware) to allow its balanced and reliable operation. Smart grids means that not only the hardware connection for energy distribution is needed; also smart elements for network management are getting involved in this new paradigm. These elements include elements for load balance, management of generation/consumption peaks, fails and blackout proactive prevention, remote monitoring of...

Open the catalog to page 16

All PREMO catalogs and technical brochures

  1. KGEA-BFCR

    1 Pages

  2. TR1102CAP

    1 Pages

  3. TP0702UCAP

    1 Pages

  4. TP0702U

    1 Pages

  5. TP0602

    1 Pages

  6. TP0502

    1 Pages

  7. RCA-ROD

    2 Pages

  8. KGEA-HB

    1 Pages

  9. KGEA-TH

    1 Pages

  10. KGEA-BFCWX

    1 Pages

  11. SEA

    1 Pages

  12. 4DC15NF

    3 Pages

  13. 2D1D15

    2 Pages

  14. SDTR1103-HF2

    1 Pages

  15. 3DC11CAP

    1 Pages

  16. ZAC1203

    1 Pages

  17. SDTR1103

    1 Pages

  18. TR1102

    1 Pages

  19. TP0702CAP

    1 Pages

  20. TP0702

    1 Pages

  21. EMC FILTERS

    110 Pages

  22. FVDT

    87 Pages

  23. Transformers

    89 Pages

  24. Ferrite Cores

    42 Pages

  25. TAGS

    41 Pages

  26. Transponder

    32 Pages

  27. SMD Inductors

    57 Pages

Archived catalogs