video corpo

ODX-6000
9Pages

{{requestButtons}}

Catalog excerpts

ODX-6000 - 1

ODX-6000 6000VA DC/AC INVERTER GENERAL FEATURES: Sine wave output voltage Suitable for motors control Adjustable output frequency Adjustable output voltage High input-output isolation 3000Vrms Remote off opto-coupled Alarm by isolated relay contacts Configurable input: Reverse or Mid power Remote control via RS232 CAN BUS (optional) Parallelable output (optional) Railway version EN50155 (optional) Fire and smoke: EN45545-2 approved Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear sys

Open the catalog to page 1
ODX-6000 - 2

INPUT Input voltage range Maximum input ripple OUTPUT Nominal output voltage (Von) Output voltage range 20…100% of Von (adjust via remote control) Output frequency Load regulation Line regulation Output wave distortion THD ENVIRONMENTAL Storage temperature Operating temperature: Full load Relative humidity without condensation Internal controlled internal fan Emissions according SAFETY Dielectric strength: Input /output Dielectric strength: Output / Earth Dielectric strength: Input / Earth MECHANICAL Weight Shock and Vibrations according to Protection degree PROTECTIONS Against overloads...

Open the catalog to page 2
ODX-6000 - 3

ORDERING CODES Input voltage range [V] Max. Output Input voltage current AC [A] [V] Active output power [W] Appar. output power [VA] Output peak current Efficien. No load input 5s (rms) (Iopk) current 10ms [%] [A] [A] [A] ODX–6000–75_ _–_ _ _ L CANBUS (Optional) P Parallelable (Optional) B Industrial version T Railway version according to EN50155 Model number Accessories must be ordered in a separate order line Please check availability for model ODX-6000-7503 or L and P options www.premiumpsu.com Powering Your Challenge

Open the catalog to page 3
ODX-6000 - 4

ODX-6000 6000VA DC/AC BLOCKS DIAGRAM DESCRIPTION The ODX-6000 consists of three phase sine-wave DC-AC inverters with galvanic isolation between input and output. The unit allows: • Changing the output frequency by means of DIP-switch7 of SW1. OFF: 50Hz or default programmed, ON: 60Hz • Change local/remote (waiting RS-232 commands) by means of DIP-switch-6 of SW1. OFF: local, ON: remote • Shutdown applying voltage output 15 to 143V on pins 3 and 4 of J4 • Start-up motors by means of a soft start. In the start-up, the output voltage rises linearly from 0V to set voltage and the frequency from...

Open the catalog to page 4
ODX-6000 - 5

ODX-6000 6000VA DC/AC RS232 communication port It is possible to control and monitor de unit via RS232 by means of an application tool named PAM. This application is free and can be downloaded from the Premium web side Also it is possible to control and monitor de unit directly using the protocol showed in table: Protocol configuration: ASCII code, 57600 bauds, parity none, 8 bits, 1bit stop Header Input voltage in Volts Input voltage ripple in Volts Output voltage in Volts RMS Phase-Neutral ([13] = char 13 of ASCII code) Output current in Amps RMS ([13] = char 13 of ASCII code) Nominal...

Open the catalog to page 5
ODX-6000 - 6

Fi Example for N=1: start-up time = N x 1.7s for changes from 16Hz to 50Hz Example for change from 50Hz / 400V to 30HZ and 240V with ramp-down of 2 cycles /Hz and ramp-up de 1 Cycle/Hz. Yellow: output voltage and Green: Mid-Power input signal WORKING PARAMETERS Thermal protection Internal warning temperature (output alarm) Internal shutdown temperature Internal restart temperature Internal temperature of fan start-up Input voltage parameters High input voltage shutdown instantaneous High input voltage timed shutdown (t) (Input alarm) Start-up voltage Low input voltage timed shutdown (t)...

Open the catalog to page 6
ODX-6000 - 7

ACCESSORIES Description Contains two brackets and screws www.premiumpsu.com Powering Your Challenge

Open the catalog to page 7
ODX-6000 - 8

EU DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: Address: PREMIUM, S. A., C/ Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Models: is in conformity with the provisions of the following EU directive(s): 2014/35/EU Electromagnetic compatibility Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and that standards and/or technical specifications referenced overleaf have been applied: EN 60950-1: 2005 Safety. Information technology equipment Safety....

Open the catalog to page 8
ODX-6000 - 9

Applicable values for the different sections of the norm EN50155: 2017 Up to 2000m Class OT1 (-25 to 55°C): load < 100% Ambient temperature Class OT3 (-25 to 70°C): load <62.5% Class OT5 (-25 to 85°C): load <25% Switch-on extended ST1 operating temp. Rapid temperature H1 variations Shocks and vibrations According EN61373:2010 Category 1 class B Working altitude Radiated emissions Conducted emissions Radiated high-frequency Magnetic field Fast transients Test Electrostatic discharge Input Output Signal PE Input L to L Input L to PE Input Output Signal PE X/Y/Z Axis Limits 40dB(µV/m) Qpk at...

Open the catalog to page 9

All PREMIUM PSU catalogs and technical brochures

Archived catalogs

  1. ECS-100

    8 Pages

  2. ODX-4500

    9 Pages

  3. ODX-3000

    9 Pages

  4. ODX-1300

    9 Pages

  5. ODS-3000

    9 Pages

  6. ODS-1500

    9 Pages

  7. ODS-750

    8 Pages

  8. OCS-260

    8 Pages

  9. CRS-1000

    10 Pages

  10. CRS-500

    8 Pages

  11. EDS-500

    7 Pages

  12. CVS-280

    7 Pages