video corpo

ODX-3000
9Pages

{{requestButtons}}

Catalog excerpts

ODX-3000 - 1

ODX-3000 2400...3000 VA DC/AC INVERTER GENERAL FEATURES: Sine wave output voltage Suitable for motors control Selectable output frequency: 50/60 Hz Adjustable output voltage High input-output isolation 3000 Vrms Remote inhibit Configurable input: Reverse or Mid power Remote control via RS232 Alarms by isolated relay contacts Remote off opto-coupled Optional railway version EN50155 Fire and smoke: EN45545-2 approved Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear s

Open the catalog to page 1
ODX-3000 - 2

INPUT Input voltage range Maximum input ripple OUTPUT Nominal output voltage (Von) Output voltage range See table 50 … 230 Vac (models of 230 Vac output) via RS232 50 … 400 Vac (models of 400 Vac output) via RS232 Output frequency Load regulation Line regulation Output wave distortion THD Storage temperature Operating temperature: Full load Operating temperature: 62.5 % load Operating temperature: 25 % load Relative humidity without condensation Maximum altitude 2000m at full load, 2500m at 95% of load According to EN61373:2011 Category 1 class B body mounted Emissions according Dielectric...

Open the catalog to page 2
ODX-3000 - 3

ORDERING CODES Input voltage range [V] Active output power [W] Appar. output power [VA] Output peak current 5 s (rms) (Iopk) 10 ms [A] [A] No load input current [A] ODX–3000–74_ _–_ _ I Remote OFF reversed (ON: applying 15…154V) Vdc) B Industrial version T Railway version according to EN50155 L Extended railway version. Includes the following: • • • • • • Lower temperature operation (-40ºC) Higher isolation input & output to earth (2500Vac) Earth connection stud Output terminals type Cage clamp Signal connectors with locking lever New enclosure style Model number Accessories must be ordered...

Open the catalog to page 3
ODX-3000 - 4

ODX-3000 2400 … 3000VA DC/AC BLOCKS DIAGRAM DESCRIPTION The ODX-3000 consists of three phase sine-wave DC-AC inverters with galvanic isolation between input and output. The unit allows: • Changing the output frequency by means of DIP-switch-1 of SW3. OFF: 50 Hz or default programmed, ON: 60 Hz • Change local/remote (waiting RS-232 commands) by means of DIP-switch-2 of SW3. OFF: local, ON: remote • Shutdown applying voltage output 15 to 154 V on pins 3 and 4 of J4 • Start-up motors by means of a soft start. In the start-up, the output voltage rises linearly from 0 V to set voltage and the...

Open the catalog to page 4
ODX-3000 - 5

ODX-3000 2400 … 3000VA DC/AC RS232 communication port It is possible to control and monitor the unit via RS232 by means of an application tool named PAM. This application is free and can be downloaded from the Premium web site It is also possible to control and monitor the unit directly using the protocol showed in table: Protocol configuration: ASCII code, 9600 bauds, parity none, 8 bits, 1bit stop Header Function Parameter V v U I Input voltage in Volts Input voltage ripple in Volts PTURS=■■■■[13]UST=■■■■[13] Output voltage in Volts RMS UTR=■■■■ ([13] = char 13 of ASCII code)...

Open the catalog to page 5
ODX-3000 - 6

Example for N=1: start-up time = N x 1.7 s for changes from 16 Hz to 50 Hz Example for change from 50Hz / 400 V to 30 Hz and 240 V with ramp-down of 2 cycles / Hz and ramp-up de 1 Cycle/Hz. Yellow: output voltage and Green: Mid-Power input signal Thermal protection Internal warning temperature(output alarm) Internal shutdown temperature Internal restart temperature Internal temperature of fan start-up Input voltage parameters High input voltage shutdown instantaneous High input voltage timed shutdown (t) (Input alarm) Low start-up input voltage Low input voltage timed shutdown (t) (Input...

Open the catalog to page 6
ODX-3000 - 7

Remark: enclosures of models B, T and L have the same dimensions and fixing holes ACCESSORIES Description Contains two brackets and screws www.premiumpsu.com Powering Your Challenge

Open the catalog to page 7
ODX-3000 - 8

EU DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: Address: PREMIUM, S. A., C/ Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Models: is in conformity with the provisions of the following EU directive(s): 2014/35/EU Electromagnetic compatibility Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and that standards and/or technical specifications referenced overleaf have been applied: EN 60950-1: 2005 Safety. Information technology equipment Safety....

Open the catalog to page 8
ODX-3000 - 9

Applicable values for the different sections of the norm EN50155: 2017 Up to 2000m at full load Working altitude Up to 2500m at 95% of load For options B and T: Class OT1 (-25 to 55 °C): load < 100 % For options B and T: Class OT3 (-25 to 70 °C): load <62.5 % For options B and T: Class OT5 (-25 to 85 °C): load <25 % Ambient temperature For option L: Class OT2 (-40 to 55 °C): load < 100 % For option L: Class OT4 (-40 to 70 °C): load <62.5 % For option L: Class OT6 (-40 to 85 °C): load <25 % Switch-on extended ST1 operating temp. Rapid temperature H1 variations Shocks and vibrations According...

Open the catalog to page 9

All PREMIUM PSU catalogs and technical brochures

Archived catalogs

  1. ECS-100

    8 Pages

  2. ODX-6000

    9 Pages

  3. ODX-4500

    9 Pages

  4. ODX-1300

    9 Pages

  5. ODS-3000

    9 Pages

  6. ODS-1500

    9 Pages

  7. ODS-750

    8 Pages

  8. OCS-260

    8 Pages

  9. CRS-1000

    10 Pages

  10. CRS-500

    8 Pages

  11. EDS-500

    7 Pages

  12. CVS-280

    7 Pages