General Features:
  • The device provides a sine wave output voltage suitable for motor control, with adjustable output frequency and voltage.
  • It offers high input-output isolation of 3000Vrms and supports remote control via RS232 and optional CAN BUS.
  • Features include parallelable output and a railway version compliant with EN50155, as well as fire and smoke approval by EN45545-2.
Specifications:
  • Input voltage range is from -30% to +25% of nominal voltage, while output voltage ranges from 20% to 100% of nominal voltage.
  • Output frequency can be set to 50/60Hz via DIP-switch or 5-75Hz via RS-232.
  • Operating temperature supports full load from -25 to 55°C, with reduced load up to 85°C.
  • Complies with EMC standards EN61000-6-2 and EN50121-3-2, and safety standards EN60950-1 and EN62368-1.
Mechanical and Environmental:
  • The device weighs less than 8950 g and has a protection degree of IP20.
  • It is cooled by an internal fan and has an MTBF of 100,000 hours at 25°C.
Protections:
  • Includes overload and over-temperature protection with auto-recovery, and input/output alarms with isolated relay contacts.
Control and Monitoring:
  • Features RS232 communication for control and monitoring, configurable input for reverse or mid-power mode, and LED indicators for output, input, and alarm status.
Ordering Information:
  • Various models are available with different input voltage ranges and power ratings, along with optional accessories and configurations like CANBUS and parallel operation.
EU Declaration of Conformity:
  • The device complies with EU directives for low voltage, electromagnetic compatibility, and RoHS, with CE marking from 2019.
Electromagnetic Compatibility (EMC) Specifications:
  • Radiated RF Immunity is specified at 10V/m from 1.4 to 2.1 GHz, 5V/m from 2.1 to 2.5 GHz, and 3V/m from 5.1 to 6 GHz, all with 80% modulation at 1 kHz.
  • Fast Transients protection up to ±2kV, Surge Protection up to ±1kV line-to-line and ±2kV line-to-earth, and Conducted RF Immunity up to 10V from 0.15 to 80 MHz.
  • Magnetic Field Immunity is up to 300A/m across X, Y, and Z axes at 0Hz, 16.7Hz, and 50/60Hz.
Environmental and Power Specifications:
  • Operates in relative humidity up to 95% and supports a DC power supply range from 0.70 to 1.25 Un continuously.
  • Handles temporary DC power supply fluctuations from 0.60 to 1.40 Un for 0.1s and from 1.25 to 1.40 Un for 1s without damage.
  • Voltage supply interruptions are classified as S1, indicating no interruptions, with an input ripple factor of 10% peak to peak.
  • Supply change-over is supported for 0.6 Un duration for 100 ms without interruptions, meeting Performance Criterion A.
  • Input reverse polarity protection is achieved by an external fuse, and PCB assemblies have a protective coating of Class PC2.
Testing Procedures:
  • Includes visual inspection, performance test, power supply test, insulation test, low temperature storage and start-up tests, dry heat and cyclic damp heat tests, salt mist test, enclosure protection test (IP Code), EMC test, shocks and vibrations test, equipment stress screening test, and rapid temperature variation test.
  • Routine tests are conducted for 24 hours at 40°C under full load conditions.
See more

Catalog excerpts

ODX-6000-1

ODX-6000 6000VA DC/AC INVERTER GENERAL FEATURES: Sine wave output voltage Suitable for motors control Adjustable output frequency Adjustable output voltage High input-output isolation 3000Vrms Remote off opto-coupled Alarm by isolated relay contacts Configurable input: Reverse or Mid power Remote control via RS232 CAN BUS (optional) Parallelable output (optional) Railway version EN50155 (optional) Fire and smoke: EN45545-2 approved Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear sys

 Open the catalog to page 1
ODX-6000-2

INPUT Input voltage range Maximum input ripple OUTPUT Nominal output voltage (Von) Output voltage range 20…100% of Von (adjust via remote control) Output frequency Load regulation Line regulation Output wave distortion THD ENVIRONMENTAL Storage temperature Operating temperature: Full load Relative humidity without condensation Internal controlled internal fan Emissions according SAFETY Dielectric strength: Input /output Dielectric strength: Output / Earth Dielectric strength: Input / Earth MECHANICAL Weight Shock and Vibrations according to Protection degree PROTECTIONS Against overloads Current...

 Open the catalog to page 2
ODX-6000-3

ORDERING CODES Input voltage range [V] Max. Output Input voltage current AC [A] [V] Active output power [W] Appar. output power [VA] Output peak current Efficien. No load input 5s (rms) (Iopk) current 10ms [%] [A] [A] [A] ODX–6000–75_ _–_ _ _ L CANBUS (Optional) P Parallelable (Optional) B Industrial version T Railway version according to EN50155 Model number Accessories must be ordered in a separate order line Please check availability for model ODX-6000-7503 or L and P options www.premiumpsu.com Powering Your Challenge

 Open the catalog to page 3
ODX-6000-4

ODX-6000 6000VA DC/AC BLOCKS DIAGRAM DESCRIPTION The ODX-6000 consists of three phase sine-wave DC-AC inverters with galvanic isolation between input and output. The unit allows: • Changing the output frequency by means of DIP-switch7 of SW1. OFF: 50Hz or default programmed, ON: 60Hz • Change local/remote (waiting RS-232 commands) by means of DIP-switch-6 of SW1. OFF: local, ON: remote • Shutdown applying voltage output 15 to 143V on pins 3 and 4 of J4 • Start-up motors by means of a soft start. In the start-up, the output voltage rises linearly from 0V to set voltage and the frequency from the...

 Open the catalog to page 4
ODX-6000-5

ODX-6000 6000VA DC/AC RS232 communication port It is possible to control and monitor de unit via RS232 by means of an application tool named PAM. This application is free and can be downloaded from the Premium web side Also it is possible to control and monitor de unit directly using the protocol showed in table: Protocol configuration: ASCII code, 57600 bauds, parity none, 8 bits, 1bit stop Header Input voltage in Volts Input voltage ripple in Volts Output voltage in Volts RMS Phase-Neutral ([13] = char 13 of ASCII code) Output current in Amps RMS ([13] = char 13 of ASCII code) Nominal output...

 Open the catalog to page 5
ODX-6000-6

Fi Example for N=1: start-up time = N x 1.7s for changes from 16Hz to 50Hz Example for change from 50Hz / 400V to 30HZ and 240V with ramp-down of 2 cycles /Hz and ramp-up de 1 Cycle/Hz. Yellow: output voltage and Green: Mid-Power input signal WORKING PARAMETERS Thermal protection Internal warning temperature (output alarm) Internal shutdown temperature Internal restart temperature Internal temperature of fan start-up Input voltage parameters High input voltage shutdown instantaneous High input voltage timed shutdown (t) (Input alarm) Start-up voltage Low input voltage timed shutdown (t) (Input...

 Open the catalog to page 6
ODX-6000-7

ACCESSORIES Description Contains two brackets and screws www.premiumpsu.com Powering Your Challenge

 Open the catalog to page 7
ODX-6000-8

EU DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: Address: PREMIUM, S. A., C/ Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Models: is in conformity with the provisions of the following EU directive(s): 2014/35/EU Electromagnetic compatibility Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and that standards and/or technical specifications referenced overleaf have been applied: EN 60950-1: 2005 Safety. Information technology equipment Safety. Audio/video,...

 Open the catalog to page 8
ODX-6000-9

Applicable values for the different sections of the norm EN50155: 2017 Up to 2000m Class OT1 (-25 to 55°C): load < 100% Ambient temperature Class OT3 (-25 to 70°C): load <62.5% Class OT5 (-25 to 85°C): load <25% Switch-on extended ST1 operating temp. Rapid temperature H1 variations Shocks and vibrations According EN61373:2010 Category 1 class B Working altitude Radiated emissions Conducted emissions Radiated high-frequency Magnetic field Fast transients Test Electrostatic discharge Input Output Signal PE Input L to L Input L to PE Input Output Signal PE X/Y/Z Axis Limits 40dB(µV/m) Qpk at 10m...

 Open the catalog to page 9

All PREMIUM PSU catalogs and technical brochures

Archived catalogs

  1. CVS-280

    7  Pages

  2. EDS-500

    7  Pages

  3. CRS-500

    8  Pages

  4. CRS-1000

    10  Pages

  5. OCS-260

    8  Pages

  6. ODS-750

    8  Pages

  7. ODS-1500

    9  Pages

  8. ODS-3000

    9  Pages

  9. ODX-1300

    9  Pages

  10. ODX-3000

    9  Pages

  11. ODX-4500

    9  Pages

  12. ECS-100

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.