video corpo

ODX-4500
9Pages

{{requestButtons}}

Catalog excerpts

ODX-4500 - 1

ODX-4500 4500VA DC/AC INVERTER GENERAL FEATURES: Sine wave output voltage Suitable for motors control Selectable output frequency: 50/60Hz Adjustable output voltage High input-output isolation 3000Vrms Remote inhibit Configurable input: Reverse or Mid power Remote control via RS232 Alarms by isolated relay contacts Remote off opto-coupled Optional railway version EN50155 Fire and smoke: EN45545-2 approved Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear syste

Open the catalog to page 1
ODX-4500 - 2

INPUT Input voltage range Maximum input ripple OUTPUT Nominal output voltage (Von) Output voltage range Output frequency Load regulation Line regulation Output wave distortion THD ENVIRONMENTAL Storage temperature Operating temperature: Full load Relative humidity without condensation Emissions according SAFETY Dielectric strength: Input /output Dielectric strength: Output / ground Dielectric strength: Input / ground EN45545-2 (only for T railway versions) MECHANICAL Weight Shock and Vibrations according to PROTECTIONS Against overloads Current and I²T limited (see overload protection)...

Open the catalog to page 2
ODX-4500 - 3

ORDERING CODES Input voltage range [V] Output current Active output power [W] Appar. output power [VA] Output peakcurrent 5s (rms) (Iopk) 10ms [A] [A] No load input current [A] B Industrial version T Railway version according to EN50155 Model number Accessories must be ordered in a separate order line www.premiumpsu.com Powering Your Challenge

Open the catalog to page 3
ODX-4500 - 4

ODX-4500 4500 VA DC/AC BLOCKS DIAGRAM DESCRIPTION The ODX-4500 consists of three phase sine-wave DC-AC inverters with galvanic isolation between input and output. The unit allows: • Changing the output frequency by means of DIP-switch1of SW3. OFF: 50Hz or default programmed, ON: 60Hz • Change local/remote (waiting RS-232 commands) by means of DIP-switch-2 of SW3. OFF: local, ON: remote • Shutdown applying voltage output 15 to 143V on pins 3 and 4 of J4 • Start-up motors by means of a soft start. In the startup, the output voltage rises linearly from 0V to set voltage and the frequency from...

Open the catalog to page 4
ODX-4500 - 5

ODX-4500 4500 VA DC/AC RS232 communication port It is possible to control and monitor de unit via RS232 by means of an application tool named PAM. This application is free and can be downloaded from the Premium web side Also it is possible to control and monitor de unit directly using the protocol showed in table: Protocol configuration: ASCII code, 9600 bauds, parity none, 8 bits, 1bit stop Header Function Parameter Input voltage in Volts Input voltage ripple in Volts PTURS=■■■■[13]UST=■■■■[13] Output voltage in Volts RMS UTR=■■■■ ([13] = char 13 of ASCII code) Nominal output frequency in...

Open the catalog to page 5
ODX-4500 - 6

Fi Example for N=1: start-up time = N x 1.7s for changes from 16Hz to 50Hz Example for change from 50Hz / 400V to 30HZ and 240V with ramp-down of 2 cycles /Hz and ramp-up de 1 Cycle/Hz. Yellow: output voltage and Green: Mid-Power input signal WORKING PARAMETERS Thermal protection Internal warning temperature(output alarm) Internal shutdown temperature Internal restart temperature Internal temperature of fan start-up Input voltage parameters High input voltage shutdown instantaneous High input voltage timed shutdown (t) (Input alarm) Low start-up voltage Low input voltage timed shutdown (t)...

Open the catalog to page 6
ODX-4500 - 7

ACCESSORIES Description Contains two brackets and screws www.premiumpsu.com Powering Your Challenge

Open the catalog to page 7
ODX-4500 - 8

EU DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: Address: PREMIUM, S. A., C/ Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Models: is in conformity with the provisions of the following EU directive(s): 2014/35/EU Electromagnetic compatibility Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and that standards and/or technical specifications referenced overleaf have been applied: EN 60950-1: 2005 Safety. Information technology equipment Safety....

Open the catalog to page 8
ODX-4500 - 9

ANNEXE Applicable values for the different sections of the norm EN50155: 2017 4.3.1 Working altitude Ambient temperature Switch-on extended operating temp. Rapid temperature variations Shocks and vibrations Radiated emissions Conducted emissions Test EMC Electromagnetic Compatibility 4.3.6 EN50121-3-2:2016 40dB(µV/m) Qpk at 10m 47dB(µV/m) Qpk at 10m Do not apply Internal freq. < 108MHz 99dB(µV) Qpk 93dB(µV) Qpk Electrostatic discharge Radiated high-frequency Fast transients Input Output Signal PE Input L to L Input L to PE Input Output Signal PE P= Performance criteria, L= Line, PE=...

Open the catalog to page 9

All PREMIUM PSU catalogs and technical brochures

Archived catalogs

  1. ECS-100

    8 Pages

  2. ODX-6000

    9 Pages

  3. ODX-3000

    9 Pages

  4. ODX-1300

    9 Pages

  5. ODS-3000

    9 Pages

  6. ODS-1500

    9 Pages

  7. ODS-750

    8 Pages

  8. OCS-260

    8 Pages

  9. CRS-1000

    10 Pages

  10. CRS-500

    8 Pages

  11. EDS-500

    7 Pages

  12. CVS-280

    7 Pages