ODX-1300 - 1

ODX-1300 1300VA DC/AC INVERTER GENERAL FEATURES: Sine wave output voltage Suitable for motors control Adjustable output voltage High input-output isolation 3000Vrms Remote control via RS232 Alarm by isolated relay contacts Remote ON/OFF opto-coupled According to the standard EN50155 Fire and smoke: EN45545-2 approved Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear syste

Open the catalog to page 1
ODX-1300 - 2

INPUT Input voltage range Maximum input ripple Inrush current Polarity protection OUTPUT Nominal output voltage (Von) Output voltage range See table (ordering codes) 150 … 250V (models of 250V output) via RS-232 200 … 400V (models of 400V output) via RS-232 Output frequency range Load regulation Line regulation Output wave distortion THD ENVIRONMENTAL Storage temperature Operating temperature: Full load Relative humidity without condensation Emissions according SAFETY Dielectric strength: Input /output Dielectric strength: Output / Earth Dielectric strength: Input / Earth Dielectric...

Open the catalog to page 2
ODX-1300 - 3

ORDERING CODES Input voltage DC [V] Input voltage range [V] Output current Appar. output power [VA] Output peakcurrent 10ms (Iopk) [A] Active output power [W] www.premiumpsu.com Powering Your Challenge No load input current [A]

Open the catalog to page 3
ODX-1300 - 4

ODX-1300 1300 VA DC/AC BLOCKS DIAGRAM DESCRIPTION The ODX-1300 consists of three phase sine-wave DC-AC inverters with galvanic isolation between input and output. The unit allows: • Start-up motors by means of a soft start. In the startup, the output voltage and frequency rise linearly from 0V to set voltage and from 5Hz to set frequency. The start-up ramp slope may be changed via RS-232 port • Set the rotation speed of a motor according to the appropriate Voltage/Frequency ratio. • Monitoring the status of the input and output. • Set and monitor parameters via RS-232. RS232 Monitoring...

Open the catalog to page 4
ODX-1300 - 5

RS232 communication port It is possible to control and monitor de unit via RS232 by means of an application tool named PAM. This application is free and can be downloaded from the Premium web side Also it is possible to control and monitor de unit directly using the protocol showed in table: Protocol configuration: ASCII code, 9600 bauds, parity none, 8 bits, 1bit stop Header Output voltage in Volts RMS Output frequency in Hz Inverter status 999.9 → Enabled Model number Firmware version Other character 000.0 → Disabled 111.1 → Inverter blocked by overload or short-circuit Command not...

Open the catalog to page 5
ODX-1300 - 6

Fi Example for N=1: start-up time = N x 1.7s for changes from 16Hz to 50Hz DEFAULT WORKING PARAMETERS Thermal protection Internal shutdown temperature Internal restart temperature Internal temperature of fan start-up Input voltage parameters Low input voltage timed shutdown (t) (Input alarm) Low input voltage instantaneous shutdown Time to shutdown (t) Output voltage parameters Output voltage Output under-voltage shutdown Warning voltage (output alarm) Initial start-up frequency Soft start duration Ramp-up V/F Output current parameters Maximum continuous output current Time between restart...

Open the catalog to page 6
ODX-1300 - 7

www.premiumpsu.com Powering Your Challenge

Open the catalog to page 7
ODX-1300 - 8

EU DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: Address: PREMIUM, S. A., C/ DolorsAleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Models: is in conformity with the provisions of the following EU directive(s): 2014/35/EU Electromagnetic compatibility Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and that standards and/or technical specifications referenced overleaf have been applied: EN 60950-1: 2005 Safety. Information technology equipment Safety....

Open the catalog to page 8
ODX-1300 - 9

ANNEXE Applicable values for the different sections of the norm EN50155: 2017 4.3.1 Working altitude Ambient temperature Switch-on extended operating temp. Rapid temperature variations Shocks and vibrations Up to 2000m Class OT1 (-25 to 55°C): load < 100% Class OT3 (-25 to 70°C): load <62.5% Class OT5 (-25 to 85°C): load <25% ST1 H1 According EN61373:2010 Category 1 class B Test Radiated emissions Conducted emissions 40dB(µV/m) Qpk at 10m 47dB(µV/m) Qpk at 10m Do not apply Internal freq. < 108MHz 99dB(µV) Qpk 93dB(µV) Qpk Electrostatic discharge EMC Electromagnetic Compatibility 4.3.6...

Open the catalog to page 9

All PREMIUM PSU catalogs and technical brochures

Archived catalogs

  1. ECS-100

    8 Pages

  2. ODX-6000

    9 Pages

  3. ODX-4500

    9 Pages

  4. ODX-3000

    9 Pages

  5. ODS-3000

    9 Pages

  6. ODS-1500

    9 Pages

  7. ODS-750

    8 Pages

  8. OCS-260

    8 Pages

  9. CRS-1000

    10 Pages

  10. CRS-500

    8 Pages

  11. EDS-500

    7 Pages

  12. CVS-280

    7 Pages