ODS-750

ODS-750

ODS-750

Product catalog summary
General Features:
Sine wave output voltage with selectable frequency (50/60Hz) and high input-output isolation (3000Vrms). Includes remote inhibit, input and output alarms, and optional railway version compliant with EN50155 and RIA12. Fire and smoke standards approved by EN45545-2.
Electrical Specifications:
Input voltage ranges from 9.5V to 138V depending on the model. Output voltage is either 120Vac or 230Vac with a sinusoidal waveform. Load regulation is 4%, and line regulation varies with input voltage changes. Output frequency is stable at 50/60Hz ± 0.25Hz with THD < 2%.
Environmental Conditions:
Storage temperature ranges from -40°C to 85°C, while operating temperatures vary based on load. Cooling is managed by a variable speed internal fan. The device has an MTBF of 160,000 hours at 25°C.
Safety and EMC:
Complies with EN60950 for safety and EN61000-6-2/EN50121-3-2 for EMC immunity and emissions. Dielectric strength tests ensure isolation between input, output, and earth.
Mechanical and Installation:
Weighs 1950g with dimensions of 130 x 270 x 50mm. Includes protections against over-currents, overloads, and over-temperature. Installation requires specific mounting and connection guidelines, including the use of external fuses and appropriate cable sections.
Ordering and Accessories:
Models are available with different input voltages and power ratings. Accessories such as DIN rail clips and mounting bases are available separately.
EU Declaration of Conformity:
The product complies with EU directives on low voltage, electromagnetic compatibility, and RoHS. It meets various EN standards for safety and EMC, including optional railway application standards.
Annexes:
Details on compliance with EN50155 and RIA12 standards, including environmental and electrical testing requirements, are provided.
See more

Catalog excerpts

ODS-750-1

GENERAL FEATURES: Sine wave output voltage Selectable output frequency: 50/60Hz High input-output isolation 3000Vrms Remote inhibit Input and output alarm Railway version EN50155, RIA12 (optional) Fire and smoke: EN45545-2 approved : Startup voltage ≤ 10.2V. Undervoltage shutdown < 9.5V Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nucle

 Open the catalog to page 1
ODS-750-2

INPUT Input voltage range Maximum input ripple OUTPUT Output voltage Output voltage adjustment range Load regulation Line regulation Output frequency Output wave distortion THD Output voltage HF ripple ENVIRONMENTAL Storage temperature Operating temperature full load Operating temperature 50% load Variable speed internal fan SAFETY Safety according to Dielectric strength: Input /output Dielectric strength: Output / Earth Dielectric strength: Input / Earth MECHANICAL Weight PROTECTIONS Against input over-currents Internal fuse for 36, 48, 72, and 110V input models Against output overloads < 10A...

 Open the catalog to page 2
ODS-750-3

ORDERING CODES Input voltage range [V] Output current Appar. output power [VA] Output peak curr. 10ms [A] Active output power [W] No load input current [A] T Railway version according to EN50155 U Railway version according to EN50155 and RIA12* *RIA12 version only available for ODS-750-7273U and 7277U (rest available upon request) Model number Accessories must be ordered in a separated order line

 Open the catalog to page 3
ODS-750-4

BLOCKS DIAGRAM DESCRIPTION The ODS-750 consists of sine-wave 120Vac or 230Vac output voltage DC-AC converters. The frequency can be set to 50Hz or 60 Hz, and input and output are galvanically isolated. The ODS-750 inverters consist of two cascaded converters,one DC-DC generating an intermediate output voltage from the input voltage. That intermediate voltage is inverted to supply the output voltage and frequency by means of a second DC/AC converter. The input is protected against reverse polarity by means of fuse and against under-voltage by unit shutdown. The output has protection of maximum...

 Open the catalog to page 4
ODS-750-5

(*) M3 threaded hole. Maximum screw depth: 3mm ACCESSORIES ACCESSORIES Screws included. Order 2 units per inverter Mounting base Screws included Mechanical Interface for subrackof 6U 11Te Screws included

 Open the catalog to page 5
ODS-750-6

EU DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: Address: PREMIUM, S. A., C/. Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Models: is in conformity with the provisions of the following EU directive(s): 2014/35/EU Electromagnetic compatibility Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and that standards and/or technical specifications referenced overleaf have been applied: EN 60950: 2005 Safety (Information technology equipment) Safety. Audio/video,...

 Open the catalog to page 6
ODS-750-7

Applicable values for the different sections of the norm EN50155: 2017 4.3.1 4.3.2 Working altitude Ambient temperature Switch-on extended operating temp. Rapid temperature variations Shocks and vibrations load load load load < 100% < 100% (Without connectors handling) <50% <50% (Without Connectors handling) ST1 H1 According EN61373:2010 Category 1 class B Test Radiated emissions Conducted emissions Electrostatic discharge Radiated high-frequency Fast transients Magnetic field Pulse magnetic field Input Output Signal PE Input L to L Input L to PE Input Output Signal PE X/Y/Z Axis Limits 40dB(µV/m)...

 Open the catalog to page 7
ODS-750-8

Applicable values for the different sections of the norm RIA12 Type of disturbance 5.2 Supply related surge Direct transient Indirect coupled transient Voltage level Source impedance

 Open the catalog to page 8

All PREMIUM PSU catalogs and technical brochures

Archived catalogs

  1. CVS-280

    7  Pages

  2. EDS-500

    7  Pages

  3. CRS-500

    8  Pages

  4. CRS-1000

    10  Pages

  5. OCS-260

    8  Pages

  6. ODS-1500

    9  Pages

  7. ODS-3000

    9  Pages

  8. ODX-1300

    9  Pages

  9. ODX-3000

    9  Pages

  10. ODX-4500

    9  Pages

  11. ODX-6000

    9  Pages

  12. ECS-100

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.