video corpo

ODS-3000
9Pages

{{requestButtons}}

Catalog excerpts

ODS-3000 - 1

ODS-3000 2400...4000VA DC/AC INVERTER GENERAL FEATURES: Sine wave output voltage Selectable output frequency: 50/60Hz Adjustable output voltage High input-output isolation 3000Vrms Remote inhibit Remote control via RS232 Alarm by isolated relay contacts Remote off opto-coupled Optional railway version EN50155 Fire and smoke: EN45545-2 approved Efficiency up to 91% Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear

Open the catalog to page 1
ODS-3000 - 2

INPUT Input voltage range Maximum input ripple OUTPUT Output voltage Output frequency Load regulation Line regulation Output wave distortion THD Storage temperature Operating temperature at full load Operating temperature at 62.5% load Relative humidity without condensation Emissions according SAFETY Dielectric strength: Input /output Dielectric strength: Output / Earth Dielectric strength: Input / Earth MECHANICAL Weight Protection degree PROTECTIONS Against overloads Current and I²T limited (see overload protection) Against over-temperature Shutdown with auto-recovery Output failure alarm...

Open the catalog to page 2
ODS-3000 - 3

ORDERING CODES Input voltage range [V] Output Active Appar. Output peak current Efficien. No load current output output input (rms) (Iopk) power power current 5s 10ms [A] [W] [VA] [%] [A] [A] [A] ODS–3000–71_ _–_ B Industrial version T Railway version according to EN50155 L Railway version according to EN50155 -40°C Model number Accessories must be ordered in a separated order line www.premiumpsu.com Powering Your Challenge

Open the catalog to page 3
ODS-3000 - 4

ODS-3000 2400 … 4000 VA DC/AC BLOCKS DIAGRAM DESCRIPTION The ODS-3000 consists of single phase sine-wave DC/AC inverters with galvanic isolation between input and output The unit allows:  Select 50 / 60Hz by means of DIP-switch.  Select local / remote (RS-232) by means of DIP-switch  Shutdown applying voltage on pins 3 and 4 of signal connector  Local signalization of Output OK by means of green LED  Local alarm. Red LED ON when:  Output current >OUTPUT CURRENT ALARM Input voltage out of margins Unit shutdowns by over-current or remote OFF  Remote alarm. Open contacts when output...

Open the catalog to page 4
ODS-3000 - 5

RS232 communication port It is possible to control and monitor de unit via RS232 by means of an application tool named PAM. This application is free and can be downloaded from the Premium web side Also it is possible to control and monitor de unit directly using the protocol showed in table: Protocol configuration:ASCII code, 19200 bauds, parity none, 8 bits, 1bit stop Header Input voltage in Volts Output voltage in Volts RMS Output current in Amps RMS Output power in W Inverter state 000.0→ Inverter disabled 222.2→ Inverter blocked by overload 111.1→ Inverter blocked by overload or...

Open the catalog to page 5
ODS-3000 - 6

WORKING PARAMETERS Thermal protection Internal warning temperature Internal shutdown temperature Internal restart temperature after overtemperature shutdown Input voltage parameters Max. input voltage shutdown instantaneous Max. input voltage shutdown timed 0.1s Maximum star-up voltage Minimum star-up voltage Min. input voltage shutdown timed 0.1s Min. input voltage shutdown instantaneous Output voltage parameters Output voltage of short circuit or deep overload Time of start-up after shutdown by shortcircuit Number of start-up attempts afterashort circuit Output current parameters Warning...

Open the catalog to page 6
ODS-3000 - 7

Maximum depth for the screws M4: 4.5mm ACCESSORIES Description Signals female connector Contains two brackets and screws 2U 19" rack mounting tray kit. Allows to install one or two units www.premiumpsu.com Powering Your Challenge

Open the catalog to page 7
ODS-3000 - 8

EU DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: Address: PREMIUM, S. A., C/ Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Models: is in conformity with the provisions of the following EU directive(s): 2014/35/EU Electromagnetic compatibility Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and that standards and/or technical specifications referenced overleaf have been applied: EN 60950-1: 2005 Safety. Information technology equipment Safety....

Open the catalog to page 8
ODS-3000 - 9

ANNEXE Applicable values for the different sections of the norm EN50155: 2017 4.3.1 Working altitude Ambient temperature Switch-on extended operating temp. Rapid temperature variations Shocks and vibrations load load load load load load < 100% < 100% (Without connectors handling) <75% <75% (Without Connectors handling) <37.5% <37.5% (Without Connectors handling) ST1 H1 According EN61373:2010 Category 1 class B Test Radiated emissions Conducted emissions 40dB(µV/m) Qpk at 10m 47dB(µV/m) Qpk at 10m Do not apply Internal freq. < 108MHz 99dB(µV) Qpk 93dB(µV) Qpk Electrostatic discharge EMC...

Open the catalog to page 9

All PREMIUM PSU catalogs and technical brochures

Archived catalogs

  1. ECS-100

    8 Pages

  2. ODX-6000

    9 Pages

  3. ODX-4500

    9 Pages

  4. ODX-3000

    9 Pages

  5. ODX-1300

    9 Pages

  6. ODS-1500

    9 Pages

  7. ODS-750

    8 Pages

  8. OCS-260

    8 Pages

  9. CRS-1000

    10 Pages

  10. CRS-500

    8 Pages

  11. EDS-500

    7 Pages

  12. CVS-280

    7 Pages