HALO DB-20 UV-VIS Double Beam Spectrophotometer

HALO DB-20 UV-VIS Double Beam Spectrophotometer

HALO DB-20 UV-VIS Double Beam Spectrophotometer

Product catalog summary
Micro Flow Cuvette Holder
Designed for continuous measurement of trace samples, allowing direct injection into the flow cuvette. Key specifications include a capacity of 70µl, pressure tolerance up to 0.1Mpa, and an optical path length of 10mm. Teflon tubing is provided.
Glass Sample Holder
Used for measuring transmittance/absorbance of glass samples or filters. It accommodates glass samples with thicknesses from 0.5mm to 5mm and dimensions ranging from 12x25mm to 55x100mm.
Film Sample Holder
Designed for measuring transmittance to absorbance of thin film-like samples. It supports film dimensions of 25mm width and 30 to 50mm height, with a beam aperture of 10mm width by 20mm height.
HALO DB-20 / DB-20S Specifications
These spectrophotometers feature concave diffraction grating optics and a double beam principle. They cover a wavelength range of 190nm to 1,100nm with spectral bandwidths of 1.5nm for DB-20 and 1.0nm for DB-20S. Stray light is less than 0.05% for DB-20 and 0.10% for DB-20S. Other specifications include a photometric range of -3 to +3 Absorbance, a wavelength scan speed up to 3,600 nm/minute, and a baseline stability of 0.0003 Abs/hr.
Ordering Information
Various holders and accessories are available, including rectangular and cylindrical long-path cuvette holders, thermostatic cuvette holders, and auto sample sippers with or without temperature control. Note that some accessories are not applicable for the Halo DB-20S model.
Rectangular Long-Path Cuvette Holder
Designed for low concentration or low absorbance samples, accommodating two long-path cuvettes with optical path lengths of 10 to 100mm.
Cylindrical Long-Path Cuvette Holder
Similar to the rectangular holder but for cylindrical cuvettes.
Thermostatic Cuvette Holder
Maintains sample temperature with external water circulation, operating from room temperature to +40°C with stability of ±0.3°C.
5-Cuvette Holder / Changer
Holds up to 5 standard 10mm cuvettes on the sample beam side, with manual changeover.
6-Cuvette Holder / Changer (with electronic temperature control)
Holds up to 6 cuvettes with electronic changeover and temperature control between +20°C to +40°C, including a magnetic stirrer.
Micro-cuvette Holder
For measuring micro-volumes with 50µl micro-cuvettes, covering a wavelength range of 220 to 950nm.
Auto Sample Sipper
Facilitates rapid measurement of multiple samples, with or without temperature control. It requires a minimum sample volume of 0.7ml and has a sipper cuvette capacity of ~50µl.
See more

Catalog excerpts

HALO DB-20 UV-VIS Double Beam Spectrophotometer-1

1 Dypamica Halo DB-20/DB-20S UV / Visible Double Beam Spectrophotometer rhe Halo UB 20 sahigti perfotmanci doubla beam spectrophoiometer suiiable for many analyiical applications where a tngnc lovol of accuraCY JS reguired. Genuine Double Beam Opiics True double beam opiics ensure concurrent measurement ol the sample and rfrence for improved stabilrty. accuracY and reproducibility. The light beam is splil in Iwo using a half mirror so tha驯 one beam passes thiough Ihe sample side whilst the othei passes through the rfrence slde. Both beams are then measured on individual detectors. The r驩frence side beam also arts to sabilire phoiomelhc values in a similar manner 10 the ratio beam principle Spectral Faaturts Coma aberration 鮩limination from the concave diffraction grating achieves a hgh resolution 1.5 nm (DB-20S : 1nm) spectral bandpass and certifies compliartce of the Halo DB-20 to the stringent European Pharmacopoeia standards. Other spcifications inelude an impressive wavelength accuracy of -0 3nm. noise level 0 0003Abs (500nm) and stray light <0.05% |220nm Nal. 340nm NaN02}. Buitt-in and Diverse Range of Measurement Modes Pholometry Mode. Perform quantitative analyses in ethcr absorbance or transmittance modes Select from single wavelength, up to 6 diffrent individual wavelengths, nucleic acid/protein A260/ A280 ratios and set up calibrt ion cuves with up to 20 standards for concentration measurements Time Scan: Perform krnetic measurements for time periods ranging from I minute to >27 hours. Measurement intervais are factory preset and automatically selected when the scan time is set Wavelength scan; Perform a full spectral scan from 190 to UOOnm at any of 8 incr颩mental and preset selectable scan speeds starting from a high resolution 1 Ohm/minute up to a swift 3,600nm / minute. Data is displayed as either numencal values or a graphol spectrum. Furthermore perform downstream processing of data, such as peak / valley search or smoothing, directly on board or with the optional Halo UV Dtective software. Dual Lump Advintuge By vinue of the long life. halogen tungsten and deuterium lamps, the Halo DB 20s wavelength range is an extensive 190nm - l.lOOnm. Furthermore, the dual lamp System results in higher accuracy than corresponding xnon lamps. Lamp switdiing is automatic and selectable from a wavelength range of 325nm to 370nm. User Friandly Op驩ration and Information Rich LCD Display The extra large 190mm x 138mm, backlit LCD screen with adjustabte brighmess controt displays a large array of data also in graphies) format. The seamless and chemical rsistant keypad is designed for easy and quick slection of navigation and fonction leatures whilst protecting against any laboratory spills Other unique features inelude the 'G0 TO WL' short eut key to allow direct input of a new wavelength into an existmg measurement Validation Functions To ensure optimum instrument performance, self-diagnosis incorporating s number of parameters and wavelength calibration are automatically initiated upon start-up. Furthermore the Halo DB-20 is equipped with a GLP/GMP feature for analyses requiring validation and auditing Parameters such as wavelength accuracy, wavelength reproducibility. bandpass, baseline flatness. baseline stability and noise level can be ail validatod and the audit report printed. Stand alont or PC Op驩ration The Halo DB-20 is fully equipped and capable of executing ail functions in stand alone mode. Smply connect a standard laser printer for direct printouts of data and graphs For more advanced control. analyses and reporting, the simple slide of a switch places the Halo DB-20 under the direct control of the optional UV Dtective software mstalled on a computer with Windows* XP Pro operating System. On-Board Data Slorage Up to 20 operating programs and up to 10 sets of measurement data can be stored in the flash memory of the Halo DB-20. Programs can easily be recalled. edited and deleted. Furthermore, when in stand alone mode, data (in text format) can be downloaded directly to an external memory suefc via the USB port and transfened for further processing to any computer loaded with commercial spreadsheets (such as Microsoft"' Excel)

 Open the catalog to page 1
HALO DB-20 UV-VIS Double Beam Spectrophotometer-2

6 Rectangular Long-Path Cuvette Holder Designed for low concentration or low absorbance samples > Accommodates 2 x long–path cuvettes (sample and reference sides) > Accepts cuvettes with 6 optical path lengths of: 10,20, 30, 40, 50 & 100 mm > Outer width: 12.5mm Cylindrical Long-Path Cuvette Holder: Designed for low concentration or low absorbance samples using a cylindrical cuvette > Accommodates 2 x long–path cylindrical cuvettes (sample and reference sides) Thermostatic Cuvette Holder Designed for applications requiring incubation and/or maintenance of a sample at a constant temperature >...

 Open the catalog to page 2

All Precisa Gravimetrics AG catalogs and technical brochures

  1. XM 50 Series

    2  Pages

  2. XM 66 Series

    6  Pages

  3. BJ 165 Series

    2  Pages

  4. BJ 160 Series

    6  Pages

  5. SRM 410Series

    2  Pages

  6. XT 320 Series

    6  Pages

  7. XR 320 Series

    8  Pages

  8. Series 320 XB

    6  Pages

  9. 390 SERIES

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.