1. Catalogs
  2. PRECIA MOLEN
  3. Double-ended shear beam load cell DSL – From 5 to 100 t

Double-ended shear beam load cell DSL – From 5 to 100 t

Double-ended shear beam load cell DSL – From 5 to 100 t

Double-ended shear beam load cell DSL – From 5 to 100 t

Product catalog summary
Application
The DSL load cell is designed for weighing silos, hoppers, and vessels with medium to high capacity. It is particularly suitable for vessels that are agitated or exposed to significant thermal forces.

Description
The DSL load cell is constructed from stainless steel and is hermetically sealed to IP 68 standards. It features a double-ended shear beam design and a 'Silo Load Mount' that minimizes the impact of lateral forces. The mount allows for thermal expansion and includes an anti-lifting device. It also has a locking mechanism for installation without the load cell, reducing the risk of damage.

Available Models
The load cells are available in various capacities ranging from 5 to 100 tons, with corresponding minimum divisions and maximum load limits.

Cabling
The load cell uses a PVC 6-core screened cable with a 6 mm diameter and a length of 12 meters.

Options
Options include an ATEX version for hazardous areas, a dummy load cell for outdoor installations, and alignment shims for setups with four or more load points.

Technical Data
  • Max. number of divisions: 3000
  • Sensitivity: 2 mV/V ±0.1%
  • Total error: < ±0.017% Sn
  • Repeatability error: < ±0.015% Sn
  • Creep error (30 min.): < ±0.015% Sn
  • Initial zero range: < ±2% Sn
  • Temperature drift: Zero < ±0.01% Sn/5°C, Sensitivity < ±0.006% Sn/5°C
  • Max. deflection: 0.6...1 mm
  • Supply voltage: 1 to 15 V
  • Input impedance: 800 ±30
  • Output impedance: 700 ±3
  • Insulation resistance: > 5000 MΩ
  • Temperature compensation range: -10° / +40°C
  • Operating range: -30° / +70°C


Load Mount Technical Data
The load mount dimensions and specifications vary based on the capacity, with details provided for 5-20 t, 30-50 t, and 75-100 t models. Each model has specific dimensions, weight, and force limits.

Additional Information
The document includes a note on the importance of fitting the load cell for complete protection against lifting and provides contact information for Precia-Molen.
See more

Catalog excerpts

Double-ended shear beam load cell DSL – From 5 to 100 t-1

DSL Double-ended shear beam load cell 12/2008 Weighing of silos, hoppers and vessels of medium and high capacity. Especially suitable for weighing vessels that are agitated or subject to major thermal forces. Typical Application Description The DSL load cell is manufactured in stainless steel and is hermetically sealed to IP 68. The characteristics of the double-ended shear beam load cell, together with it’s mounting arrangement “Silo Load Mount“, ensure it is not influenced by the lateral forces associated with vessels with agitators. The load mount allows thermal expansion and includes an antilifting device. The mount also features a locking device that enables it to be installed without the load cell fitted eliminating the risk of mechanical or electrical damage to the load cell during vessel installation. Correct positioning of load mounts to avoid thermal forces. Minimum Maximum Safe load division load limit 0.5 kg 7.5 t 10 t 1 kg 15 t 20 t 2 kg 30 t 40 t 3 kg 45 t 60 t 5 kg 75 t 100 t 7.5 kg 112.5 t 150 t 10 kg 150 t 200 t Available Models Screen Screen ATEX version for use in hazardous areas. Dummy load cell (only required for outdoor installation). Set of alignment shims (if the number of load points is ≥ 4).

 Open the catalog to page 1
Double-ended shear beam load cell DSL – From 5 to 100 t-2

Load Cell Technical data              A(i) Load Mount Technical data Top plate Base plate Locking device (to be removed when fitting the load cell) Angular movement of the top plate Load point A : Minimum clearance for fitting load cell. K : 4 holes in the top and lower plates. Note : Complete protection against lifting is only provided when the load cell is fitted. Your weighing specialist Illustrations are not contractual. Precia-Molen reserves the right to modify at any time, without prior notice, the information contained in this leaflet. Offices and Factory P.O. Box 106 - F...

 Open the catalog to page 2

All PRECIA MOLEN catalogs and technical brochures

  1. WEIGH2CONTROL

    2  Pages

  2. i 25 touch

    6  Pages

  3. CKW 410 LOG

    2  Pages

  4. CKW 710

    2  Pages

  5. I 410 SYSTEM

    6  Pages

  6. PRECIA ACCESS

    8  Pages

  7. LOAD CELLS

    2  Pages

  8. HOPPER SCALES

    2  Pages

  9. Product guide

    28  Pages

  10. STORAGE SILOS

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.