Catalog excerpts
Trip amplifier 2231 – AC/DC trip amplifier – 2 adjustable alarm limits – Galvanically isolated 3.75 kVAC – Front-programmable – 3-digit LED display – 24 VDC or universal supply Advanced features • The front-operated push buttons are used for programming the different standard functions. • A password can prevent access for changing parameters. Application • Alarm detector in connection with measurement of AC/DC current or voltage signals. • The unit is used where accurate setpoint setting and different alarm functions are required. • The unit can be used as a single or dual trip amplifier. • Used in applications where programmable parameters such as hysteresis, setpoint, reset, active relay for increasing or decreasing signal, delay and input signal need to be set. Technical characteristics • 3-digit display showing the input signal in %. • Two LED indicating relay status. • 3 pushbuttons for programming. • Standard DC current input signals in the range 0...20 mA. • DC voltage signals in the range 0...250 VDC. • AC current signals up to 1 A. • True RMS measurement of AC voltage signals in the range 0...250 VAC. • Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying. This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for
Open the catalog to page 1100 ms Better than 0.1% of sel. range 16 bit < ±0.002% of span / %V < ±0.01% of span /°C (DC signals) < ±0.02% of span /°C (AC signals) < 0.1% of span < ±0.35% of span 50...1000 Hz (AC sine wave signals) < ±0.5% Output specifications
Open the catalog to page 2All PR ELECTRONICS catalogs and technical brochures
-
4225
2 Pages
-
7501
2 Pages
-
3186
2 Pages
-
3104
2 Pages
-
3103
2 Pages
-
2900 series
2 Pages
-
2200 Series
2 Pages
Archived catalogs
-
The PRofile no. 23
12 Pages
-
The PRofile no. 22
12 Pages
-
Segment folder - energy
12 Pages
-
I.S. / System 9000
8 Pages
-
PReasy 4100
6 Pages
-
Display
6 Pages
-
Signal isolation
8 Pages
-
Temperature
8 Pages